Product successfully added to your shopping cart
2CCP247204R0001
ABB
1
S802PV-M32-H High Performance Circuit Breaker Rated current 32A Rated operational voltage 1000V d.c. Icw=1.5kA Utilization category DC-21A
Int.sec. S802PV-M32-H 2p 32A 1000Vdc
S802PV-M32-H
Low-voltage industrial components > Switch disconnector
Industrial > S800PV
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| Environmental Product Declaration - EPD | 9AKK108470A1698 |
| 9AKK108470A1697 | |
| Technical | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (800 V DC) 5 kA |
| Rated Short-Circuit Making Capacity (Icm) | (1000 V DC) 0.5 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (800 V DC) 5 kA |
| Contact Position Indication | ON / OFF / TRIP |
| Number of Poles | 2P |
| Number of Switches | 8500 |
| Tightening Torque | 3.5 N·m |
| Actuator Marking | I / O |
| Recommended Screw Driver | Pozidriv 2 |
| Connecting Capacity | Flexible 0...50 mm² |
| Rigid 0...70 mm² | |
| Terminal Type | Screw Terminals |
| Electrical | |
| Rated Operational Voltage | 1000 V DC |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 1500 V DC |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Current (In) | 32 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | 1.5 kA |
| Rated Uninterrupted Current (Iu) | 32 A |
| Power Loss | Total 3.6 W |
| at Rated Operating Conditions per Pole 1.8 W | |
| Overvoltage Category | IV |
| Design | |
| Housing Material | Insulation group I, RAL 7035 |
| Control Element Color | Black |
| Material Compliance | |
| RoHS Declaration | 2CCC005117D0201 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20211214 |
| REACH Declaration | 9AKK108470A9089 |
| REACH Information | False - does not contain substances > 0.1 mass percentage |
| REACH Date | 20250313 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Business |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 70 °C |
| Storage -40 ... 70 °C | |
| Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Resistance to Vibrations | 1 mm 2 - 13.2 Hz |
| 0.7g with Load 100% x Ie 13.2 - 100 Hz | |
| Resistance to Shock acc. to IEC 60068-2-27 | 5 g |
| 30 ms | |
| Environmental Information | 2CCY413207D0203 |
| Dimensions | |
| Width in Number of Modular Spacings | 3 |
| Product Net Width | 54 mm |
| Product Net Height | 95 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 490 g |
| Built-In Depth (t2) | 82.5 mm |
| Engineering | |
| EPLAN Data | 9AAC172533_EPLAN |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 520 g |
| Certificates and Declarations | |
| CB Certificate | 9AKK107680A0853 |
| CCC Certificate | CQC2013010302632074 |
| Declaration of Conformity - CE | 2CCC005117D0201 |
| VDE Certificate | 9AKK107680A0854 |
| Installation | |
| Instructions and Manuals | 2CCC413016M0008 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting Position | Any |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK108468A9560 |
| 9AKK108468A9561 | |
| 9AKK108468A9562 | |
| External Classifications and Standards | |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| ETIM 10 | EC000216 - Switch disconnector (AC) |
| UNSPSC | 39121603 |
| eClass | V11.0 : 27371403 |
| Object Classification Code | F |
| Standards | IEC/EN 60947-3 |
| Feature Name | Feature Value |
|---|---|
| Version as main switch (EF006981) | Yes |
| Version as maintenance-/service switch (EF006986) | No |
| Version as safety switch (EF006985) | No |
| Version as emergency stop installation (EF006959) | No |
| Version as reversing switch (EF009408) | No |
| Number of switches (EF005586) | 8500 |
| Rated permanent current Iu (EF001389) | 32 A |
| Rated short-time withstand current lcw (EF007050) | 1.5 kA |
| Number of poles (EF001391) | 2 |
| Motor drive optional (EF007386) | No |
| Motor drive integrated (EF006697) | No |
| Voltage release optional (EF007491) | Yes |
| Suitable for front mounting 4-hole (EF007247) | No |
| Suitable for front mounting centre (EF007248) | Yes |
| Suitable for distribution board installation (EF007262) | Yes |
| Suitable for intermediate mounting (EF007264) | Yes |
| Colour control element (EF007167) | Black |
| Interlockable (EF006281) | No |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.