ANUNCIAR
1SBH137001R1331 ABB NF31E-13 100-250V50/60HZ-DC Contactor Relay View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBH137001R1331 ABB NF31E-13 100-250V50/60HZ-DC Contactor Relay

1SBH137001R1331

ABB

NF31E-13 100-250V50/60HZ-DC Contactor Relay

NF31E CONT. AUX. BOB. 100-250Vac-dc

More details


Low-voltage industrial components > Contactor relay

Contactors and overload relays > AF contactors to 38 A

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $35.07
Unit price: $35.07
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
EPLAN Data9AAC159655_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals1SBC101027M6801
Instructions and Manuals (Part 2)1SAC200017M0002
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.27 kg
Technical
Number of Auxiliary Contacts NO3
Number of Auxiliary Contacts NC1
Number of Poles4P
StandardsIEC/EN 60947-1, IEC/EN 60947-5-1, UL 60335-2-40 LZGH2 A2L, UL 508, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 14-13
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
for 1 s 100 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Power Lossat 6 A per Pole 0.1 W
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Control Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening TorqueAuxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor Relay
Technical UL/CSA
Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Environmental
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
Resistance to Vibrations4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree3
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIPa000906b-ee90-4914-a705-5dbe89ad884e China
Simplified SCIP08ed39a6-d5f0-4b77-9a7c-3ad1a5fdfce0 France
50dfbd34-ce1f-4ba9-a9c8-8ea154f200e0 Sweden
e32fc31c-ba09-4e2d-b9c0-5153dee29d4b Croatia
dd5d464d-48d7-4e22-a751-c9cb6a7c51e5 Czech Republic
05c537b2-74e1-4315-b1bd-cc3488f94469 Germany
6d615b49-4560-4f9c-8a62-a6ca6cbaa101 Denmark
fcf6a977-ffc4-4a13-aa36-46647fc45834 Bulgaria
0371d898-49b5-4aa0-8544-7cf410e6f415 Belgium
7f7fe1d5-690b-420b-816c-af5ad74f49e7 Greece
06b23ae7-55ec-4400-9b4e-243a62d05505 Spain
d2055ce8-9d59-4388-b13a-6557cc1c8e49 Portugal
b79060f8-ef03-45d7-a748-e435c580b744 Belgium
3b4eb8fa-4169-4455-8d03-e5d0ed0176d5 Finland
6a9db7a1-8d74-4bdf-b9a1-706b76f087f3 Hungary
ef3b0b48-babb-42be-bd15-06d832124a2d Estonia
c1bdd10d-447a-498f-90b0-b4219b53fcc8 Hungary
c45981e2-78a5-4d77-b673-a0235182729b Netherlands
c40d1270-6aae-4508-ae94-58d2f0e5153d Poland
169c4d16-87fc-495a-a480-a72d9b0c074f Norway
a9936961-d1d2-49da-8833-c4767539bff9 Poland
b4208a2c-0fdb-49ba-8b79-48f8d32ae739 Germany
8c80b00d-c7f3-4088-b4ed-a8db0b3d4b35 France
ed5b84ba-c80a-4150-9f47-6b798bf3e6d4 Sweden
6ec38270-a4eb-49e5-a8b2-c40a8b55b0cf Germany
f711759d-136f-4625-8b4a-5528cd99b329 Germany
ebabf4ac-94de-4cc7-a6fe-b8d814487367 Germany
970cf98c-b19a-4e5b-9dba-765b1c7b9f36 Poland
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
End Of Life Disassembling Instructions1SBC101080M6801
Environmental Product Declaration - EPD1SBD250584E3000
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 92.7 %
Certificates and Declarations
A2L Certificate – UL9AKK108469A4900
9AKK108469A4902
ABS CertificateABS_20-2060694-PDA
BV CertificateBV_2634H24899C1
CB CertificateCB_SE-116792
CCC CertificateCCC_2024010303656666
Declaration of Conformity - CCCCQC2011010303465426
Declaration of Conformity - CE1SBD250005U1000
Declaration of Conformity - UKCA1SBD250036U1000
DNV CertificateDNV_TAE00001BV-5
EAC CertificateEAC_RU C-FR ME77 B03544
GOST CertificateGOST_POCCFR.ME77.B06804.pdf
KC CertificateKC-HW02016-21031A
LR CertificateLRS_LR2003684TA-02
RINA CertificateRINA_ELE142224XG
RMRS CertificateRMRS_1802702280
UL CertificateUL_20180227_E252354_2_1
UL Listing CardUL_E252354
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width87 mm
Package Level 1 Depth / Length79 mm
Package Level 1 Height47 mm
Package Level 1 Gross Weight0.27 kg
Package Level 1 EAN3471523100237
Package Level 2 Unitsbox 27 piece
Package Level 2 Width250 mm
Package Level 2 Depth / Length300 mm
Package Level 2 Height315 mm
Package Level 2 Gross Weight14.58 kg
External Classifications and Standards
Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121529
IDEA Granular Category Code (IGCC)4763 >> Power contactor, DC switching
E-Number (Finland)3706408
E-Number (Sweden)3211452

ETIM for 1SBH137001R1331 Low-voltage industrial controls and switchgear (EC000196)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 100 V
Rated control supply voltage AC 60 Hz (EF003979) 100 V
Rated control supply voltage DC (EF003980) 100 V
Voltage type for actuating (EF008242) AC/DC
Rated operation current Ie, 400 V (EF001378) 3 A
Connection type auxiliary circuit (EF006820) Screw connection
Mounting method (EF000003) DIN-rail/screw
Interface (EF000594) No
Number of auxiliary contacts as normally closed contact (EF001377) 1
Number of auxiliary contacts as normally open contact (EF001376) 3
Number of auxiliary contacts as normally closed contact, delayed switching (EF007281) 0
Number of auxiliary contacts as normally open contact, leading (EF007282) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
With LED indication (EF005950) No
Suitable for manual operation (EF002978) No

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.