MS132-6.3T 1SAM340000R1009 ABB MS132-6.3T Circuit Breaker for Primary Transformer Protection View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MS132-6.3T 1SAM340000R1009 ABB MS132-6.3T Circuit Breaker for Primary Transformer Protection

1SAM340000R1009

ABB

MS132-6.3T Circuit Breaker for Primary Transformer Protection

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Electronic motor protection relays > Electronic motor protection relays Mx116 and Mx132

* Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total price: $77.36
Unit price: $77.36

Quantity Price
1+$77.36
2+$69.38
3+$66.23
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



The circuit breaker for transformer protection MS132-6.3T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 6.3 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.

Ordering

  • EAN:
    4013614484995
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85362010

Dimensions

  • Product Net Width:
    45mm
  • Product Net Height:
    90mm
  • Product Net Depth:
    86.75mm
  • Product Net Weight:
    0.265kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    92 mm
  • Package Level 1 Height:
    50 mm
  • Package Level 1 Length:
    95 mm
  • Package Level 1 Gross Weight:
    0.28 kg
  • Package Level 2 Units:
    40 piece
  • Package Level 2 Width:
    280 mm
  • Package Level 2 Height:
    210 mm
  • Package Level 2 Length:
    395 mm
  • Package Level 2 Gross Weight:
    11.586 kg
  • Package Level 2 EAN:
    4013614487194

Environmental

  • Ambient Air Temperature:
    Around the Enclosure 0 ... +40 °C
    Operation -25 ... +70 °C
    Storage -50 ... +80 °C
  • Ambient Air Temperature Compensation:
    Yes
  • Maximum Operating Altitude Permissible:
    2000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    11 ms Pulse 25g
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    5g / 3 ... 150 Hz
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Additional Information

  • Actuator Type:
    Rotary Handle
  • Connecting Capacity-Main Circuit:
    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible 1/2x 0.75 ... 2.5 mm²
    Rigid 1/2x 1 ... 4 mm²
  • Conventional Free-air Thermal Current (Ith):
    6.3 A
    Main Circuit 6.3 A
  • Degree of Protection:
    IP20
  • Electrical Durability:
    50000 cycle
  • Mechanical Durability:
    100000 cycle
  • Mounting Position:
    Position 1 to 6
  • Number of Poles:
    3
  • Number of Protected Poles:
    3
  • Pollution Degree:
    3
  • Power Loss:
    at Rated Operating Conditions per Pole 0.7 … 1.8 W
  • Product Main Type:
    MS132
  • Product Name:
    Circuit Breaker for Primary Transformer Protection
  • Rated Frequency (f):
    Main Circuit 50 Hz
    Main Circuit 60 Hz
  • Rated Impulse Withstand Voltage (Uimp):
    Main Circuit 6 kV
  • Rated Instantaneous Short-Circuit Current Setting (Ii):
    126 A
  • Rated Insulation Voltage (Ui):
    690 V
  • Rated Operational Current (Ie):
    6.3 A
  • Rated Operational Voltage:
    Main Circuit 690 V AC
  • Rated Uninterrupted Current (Iu):
    6.3 A
  • Recommended Screw Driver:
    M4
    Pozidriv 2
  • RoHS Date:
    0149
  • Setting Range:
    4 ... 6.3 A
  • Standards:
    IEC/EN 60947-1
    IEC/EN 60947-2
    IEC/EN 60947-4-1
  • Terminal Type:
    Screw Terminals
  • Tightening Torque:
    Main Circuit 0.8 ... 1.2 N·m
  • Wire Stripping Length:
    Main Circuit 9 mm

Certificates and Declarations (Document Number)

Classifications

  • eClass:
    7.0 27370409
  • ETIM 4:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 5:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • Object Classification Code:
    F

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.