Product successfully added to your shopping cart
SK827041-DF
SK827041DF
ABB
1
Low-voltage industrial components > Power contactor, AC switching
Contactors and overload relays
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 5309660-30 |
| Dimensions | |
| Product Net Width | 296 mm |
| Product Net Depth / Length | 225.5 mm |
| Product Net Height | 272 mm |
| Product Net Weight | 15.5 kg |
| Technical | |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 2 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 4P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 800 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 800 A |
| (1000 V) 60 °C 650 A | |
| (1000 V) 70 °C 575 A | |
| (690 V) 40 °C 800 A | |
| (690 V) 55 °C 650 A | |
| (690 V) 60 °C 650 A | |
| (690 V) 70 °C 575 A | |
| Rated Operational Current AC-3 (Ie) | (440 V) 55 °C 550 A |
| (500 V) 55 °C 550 A | |
| (690 V) 55 °C 550 A | |
| (1000 V) 55 °C 175 A | |
| (380 / 400 V) 55 °C 550 A | |
| (220 / 230 / 240 V) 55 °C 550 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 315 kW |
| (440 V) 315 kW | |
| (500 V) 400 kW | |
| (690 V) 500 kW | |
| (1000 V) 35 kW | |
| (380 / 400 V) 280 kW | |
| (220 / 230 / 240 V) 160 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 1.5 ... 1.8 In A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 5300 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 5500 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3700 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-2 / AC-4) 120 cycles per hour | |
| (AC-3) 300 cycles per hour | |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | DC Operation 220 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 125 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 140 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 60 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 10 ... 20 ms |
| Between Coil De-energization and NO Contact Opening 13 ... 23 ms | |
| Between Coil Energization and NC Contact Opening 25 ... 55 ms | |
| Between Coil Energization and NO Contact Closing 30 ... 60 ms | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Connecting Terminals (delivered in open position) Main Poles | Flat type c/w screws and bolts |
| Terminal Type | Main Circuit: Bars |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| General Use Rating UL/CSA | (600 V AC) 540 A |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -50 ... 70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| SCIP | d5ead741-b942-4645-b4db-5c0f7be52273 Bulgaria |
| Simplified SCIP | add6f9ad-cbdb-4660-8f70-216bd339b105 Germany |
| f81b80ba-648e-41e3-9792-bd5a6d8b9236 Germany | |
| 8dd7e4d0-16a9-47dd-932e-b0e712171e59 France | |
| 898bc35b-e427-477d-8873-3d258f91bc44 Spain | |
| d4544449-002c-41e2-9f89-0c94ae61195c Belgium | |
| 87ad9099-c0f1-4e55-b055-dab591c263c0 Sweden | |
| 069afc4e-2de5-4022-955a-d687972e8f97 Denmark | |
| 0112bccf-0bc2-409a-812b-70bde300cf9e Croatia | |
| 771edfc6-1012-4232-a34f-bc8f5d828062 Estonia | |
| 185c27d6-b62d-4bda-b10c-3593d63ec6dc Sweden | |
| ea533f34-9166-4b7c-8ac8-550b861e0dda Poland | |
| 3ccae9f7-88fd-4d31-b788-a8a27f319a96 Hungary | |
| 3e73d05f-d5b3-477e-a6f0-36f91a6b8127 Portugal | |
| 3bce118c-980e-425c-b1b0-fc3e2520311e Germany | |
| 2fe28e60-a673-4070-b31d-e2ec579fb35b France | |
| 263d842b-68ee-4d74-8c4c-29612d5b0c84 Czech Republic | |
| 39265d5a-9a9a-4eb3-9504-dc160c3cff4c Netherlands | |
| b9fc1c38-89ca-4cd7-bbfa-2615578d30be Hungary | |
| 688c572d-2234-4945-bdf0-e8db2f86fcb3 Greece | |
| db8a37d9-6538-441f-b759-9db1329ab0b9 Poland | |
| d632040a-ac41-4a00-b885-bc293f0186a4 Finland | |
| 616e5093-577e-41d5-8320-b314edcb211f Belgium | |
| 42daa28a-065d-4c45-8b98-8bfa36c97ae0 Italy | |
| a8e9d99f-02a1-4d43-bb47-7ea3df800525 Germany | |
| 4e426955-e872-4d12-90fd-8185d6f5c0d9 Norway | |
| 9f145b62-e146-4ac3-ac47-5f563706c4b1 Germany | |
| a834d528-8dc8-462e-8273-7355b46ec9d5 Poland | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| CQC Certificate | CQC2003010304094982 |
| Declaration of Conformity - CCC | 2020980304001264 |
| Declaration of Conformity - CE | 2CMT2015-005442 |
| UL Certificate | 20161201-E36588 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 317 mm |
| Package Level 1 Depth / Length | 317 mm |
| Package Level 1 Height | 373 mm |
| Package Level 1 Gross Weight | 17.2 kg |
| Package Level 1 EAN | 7320500039557 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage DC (EF003980) | 220 V |
| Voltage type for actuating (EF008242) | DC |
| Rated operation current Ie at AC-1, 400 V (EF001393) | 800 A |
| Rated operation current Ie at AC-3, 400 V (EF001392) | 550 A |
| Rated operation power at AC-3, 400 V (EF001364) | 280 kW |
| Modular version (EF001126) | No |
| Number of auxiliary contacts as normally open contact (EF001376) | 2 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 1 |
| Type of electrical connection of main circuit (EF006819) | Rail connection |
| Number of normally closed contacts as main contact (EF001375) | 0 |
| Number of normally open contacts as main contact (EF001374) | 4 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.