EK370-40-11 SK827040-AG ABB EK370-40-11 127V 50Hz Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EK370-40-11 SK827040-AG ABB EK370-40-11 127V 50Hz Contactor

EK370-40-11

SK827040-AG

ABB

EK370-40-11 127V 50Hz Contactor

More details


Service Breakers

* Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



A 4-pole Contactor suitable for Distribution and Rail way applications AC and DC switching. Operated with control voltage, versions from 24….690 AC, 50/60 Hz and 24-220 V DC

Ordering

  • EAN:
    7320500012772
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Dimensions

  • Product Net Width:
    300mm
  • Product Net Depth:
    270mm
  • Product Net Height:
    225mm
  • Product Net Weight:
    17.5kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    355 mm
  • Package Level 1 Length:
    340 mm
  • Package Level 1 Height:
    240 mm
  • Package Level 1 Gross Weight:
    19.2 kg

Technical

  • Number of Main Contacts NO:
    4
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    1
  • Rated Operational Voltage:
    Main Circuit 1000 V
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 550 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 55 °C 470 A
    (690 V) 40 °C 550 A
    (690 V) 70 °C 400 A
  • Rated Operational Current AC-3 (Ie):
    (1000 V) 55 °C 155 A
    (690 V) 55 °C 370 A
    (220 / 230 / 240 V) 55 °C 400 A
    (440 V) 55 °C Q55C415V:370 A
    (440 V) 55 °C 400 A
    (380 / 400 V) 55 °C 400 A
    (500 V) 55 °C 370 A
  • Rated Operational Power AC-3 (Pe):
    (500 V) 250 kW
    (1000 V) 220 kW
    (220 / 230 / 240 V) 110 kW
    (690 V) 355 kW
    (380 / 400 V) 200 kW
    (440 V) 220 kW
    (415 V) 220 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Short-Circuit Protective Devices:
    gG Type Fuses 630 A
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1000 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 5300 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3700 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 5500 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3000 A
  • Maximum Electrical Switching Frequency:
    AC-3 300 cycles per hour
    AC-1 300 cycles per hour
    AC-2 / AC-4 120 cycles per hour
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Mechanical Durability:
    5 million
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1)Uc (at θ ≤ 70 °C) °C
  • Rated Control Circuit Voltage (Uc):
    50 Hz 127 V
  • Coil Consumption:
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V·A
    Holding at Max. Rated Control Circuit Voltage 50 Hz 140 V·A
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 125 V·A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 30…60 ms
    Between Coil De-energization and NO Contact Opening 13…23 ms
    Between Coil De-energization and NC Contact Closing 10…20 ms
    Between Coil Energization and NC Contact Opening 25…55 ms
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles:
    Flat type c/w screws and bolts
  • Terminal Type:
    Screw Terminals

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+55 °C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
    Close to Contactor for Storage -50…+70 °C
  • Maximum Operating Altitude Permissible:
    3000 m
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

  • General Use Rating UL/CSA:
    (600 V AC) 420 A

Certificates and Declarations (Document Number)

Classifications

  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.