Product successfully added to your shopping cart
1SBL397501R1300
ABB
1
Low-voltage industrial components > Power contactor, AC switching
Contactors and overload relays > AF contactors 40A to 100A
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC175975_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 1SBC101047M6801 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 90 mm |
| Product Net Depth / Length | 116 mm |
| Product Net Height | 125.5 mm |
| Product Net Weight | 1.44 kg |
| Technical | |
| Number of Main Contacts NO | 2 |
| Number of Main Contacts NC | 2 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22 |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Control Circuit 50 / 60 Hz |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 125 A |
| (690 V) 60 °C 105 A | |
| (690 V) 70 °C 90 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 80 A |
| (440 V) 60 °C 80 A | |
| (500 V) 60 °C 65 A | |
| (690 V) 60 °C 49 A | |
| (1000 V) 60 °C 25 A | |
| (380 / 400 V) 60 °C 80 A | |
| (220 / 230 / 240 V) 60 °C 80 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 45 kW |
| (440 V) 45 kW | |
| (500 V) 45 kW | |
| (690 V) 45 kW | |
| (1000 V) 35 kW | |
| (380 / 400 V) 37 kW | |
| (220 / 230 / 240 V) 22 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V |
| 60 Hz 100 ... 250 V | |
| DC Operation 100 ... 250 V | |
| Coil Consumption | Average Holding Value 50 / 60 Hz 4 V·A |
| Average Holding Value 50 Hz 4 V·A | |
| Average Holding Value 60 Hz 4 V·A | |
| Average Holding Value DC 2 W | |
| Average Holding Value, from Warm State 2 W | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 8 W |
| at Rated Operating Conditions AC-3 per Pole 3.2 W | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 6 ... 50 mm² |
| Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | |
| Rigid Stranded 1x 6 ... 70 mm² | |
| Rigid Stranded 2x 6 ... 50 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Rigid Solid 1/2x 1 ... 2.5 mm² | |
| Rigid Stranded 1/2x 1 ... 2.5 mm² | |
| Wire Stripping Length | Control Circuit 10 mm |
| Main Circuit 17 mm | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Recommended Screw Driver | Pozidriv PZ |
| Tightening Torque | Control Circuit 1.2 N·m |
| Main Circuit 6 N·m | |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 105 A |
| Connecting Capacity Main Circuit UL/CSA | Rigid Stranded 1/2x 6-1 AWG |
| Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Rigid Stranded 1/2x 18-14 AWG | |
| Tightening Torque UL/CSA | Control Circuit 11 in·lb |
| Main Circuit 53 in·lb | |
| Full Load Amps Motor Use | (120 V AC) Single Phase 7-1/2 A |
| (200 ... 208 V AC) Three Phase 25 A | |
| (220 ... 240 V AC) Three Phase 30 A | |
| (240 V AC) Single Phase 15 A | |
| (440 ... 480 V AC) Three Phase 60 A | |
| (550 ... 600 V AC) Three Phase 75 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air -40 ... 70 °C | |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Vibrations | 3g Closed Position & 2g Open Position 5 ... 300 Hz |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 121eed37-c21f-4f21-937c-7afbce05b43f China |
| Simplified SCIP | c859f8eb-8725-448d-b75f-0f13efce2a30 Hungary |
| e45b771e-6e1c-4c8c-a99c-4a2fceada812 Belgium | |
| 7c12f92d-dd64-4af4-82c3-7bad29f52045 France | |
| b655c814-54e1-452f-af55-6cf7318c87d4 Sweden | |
| b9d9b17b-660c-4688-b066-91806a3bdefe Denmark | |
| 0e36537b-f701-4fa7-95be-86ae0b26e8b8 Germany | |
| 033b691a-9d97-41d6-b39f-f81fb2fc758b Germany | |
| cc2b5a9e-b6b0-4c1a-a86d-4c0b13cad9a8 Spain | |
| 72ce3e01-6b5a-4f3d-8b07-50e2c4775f50 Norway | |
| 56f336d0-7840-4d31-9b67-d4c7b4ac1df3 Finland | |
| 42ef1f2c-a382-4ff0-bd7a-9b4f2a1be19f Poland | |
| 56fce833-09cd-42cc-821c-a7f4ba17eb3b Germany | |
| 1ac17399-0900-40c6-997e-3a331d87acdf Czech Republic | |
| 184fdb6c-b273-4148-8dc4-1a38051462ad Belgium | |
| 66c1a783-1500-45e5-b675-a0010439bf51 Croatia | |
| 98a2e327-4505-44c4-822c-886348f3ab26 Germany | |
| 30b9e440-b0a4-44ae-80b4-ef3c0cac6971 Germany | |
| 31983542-46ac-4251-8a65-764c1bc2213e France | |
| 1d1490bb-c89e-4d6f-a26a-bc51a7ed993f Poland | |
| 3dd1c1e1-103c-4c60-97b9-e448c443cfce Portugal | |
| 18be2448-6403-4d3b-acc1-6ec8fc7e670f Bulgaria | |
| 62d8c2e4-3bbd-4924-bece-1a7af94d3e23 Sweden | |
| 1a7f6704-2979-4161-988c-f66374b48a2c Poland | |
| 54465519-481a-45f9-82b3-eb4a3a7957ef Hungary | |
| 9bafda22-b4e5-473c-915d-60fd4c6c53c8 Estonia | |
| 442d0289-f38d-48cc-8987-ed41293ba78c Netherlands | |
| 5874aad1-457a-4d77-8426-d99881b0cb6e Greece | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| End Of Life Disassembling Instructions | 1SBC101081M6801 |
| Environmental Product Declaration - EPD | 1SBD250584E2000 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 91.9 % |
| Certificates and Declarations | |
| A2L Certificate – UL | 9AKK108469A4890 |
| 9AKK108469A4892 | |
| ABS Certificate | ABS_20-2060694-PDA |
| BV Certificate | BV_2634H36994B2 |
| CB Certificate | CB_SE-116522 |
| CCC Certificate | CCC_2024010304656667 |
| Declaration of Conformity - CCC | 2020980304001255 |
| Declaration of Conformity - CE | 1SBD250001U1000 |
| Declaration of Conformity - UKCA | 1SBD250032U1000 |
| DNV Certificate | DNV_TAE00001AF-4 |
| KC Certificate | KC_HW02016-15013C |
| UL Certificate | UL-US-L312527-1142-02114102-12 |
| UL-CA-L312527-4142-02114102-12 | |
| UL Listing Card | UL_E312527 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 150 mm |
| Package Level 1 Depth / Length | 150 mm |
| Package Level 1 Height | 103 mm |
| Package Level 1 Gross Weight | 1.57 kg |
| Package Level 1 EAN | 3471523133938 |
| Package Level 2 Units | box 8 piece |
| Package Level 2 Width | 250 mm |
| Package Level 2 Depth / Length | 300 mm |
| Package Level 2 Height | 300 mm |
| Package Level 2 Gross Weight | 12.56 kg |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3707455 |
| E-Number (Sweden) | 3210352 |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage AC 50 Hz (EF003978) | 100 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 100 V |
| Rated control supply voltage DC (EF003980) | 100 V |
| Voltage type for actuating (EF008242) | AC/DC |
| Rated operation current Ie at AC-1, 400 V (EF001393) | 125 A |
| Rated operation current Ie at AC-3, 400 V (EF001392) | 80 A |
| Rated operation power at AC-3, 400 V (EF001364) | 37 kW |
| Modular version (EF001126) | No |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Number of normally closed contacts as main contact (EF001375) | 2 |
| Number of normally open contacts as main contact (EF001374) | 2 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
| AF80-22-00-13 100-250V50/60HZ-DC Contactor - ABB - AF80-22-00-13 - 1SBL397501R1300 | 93 Kbytes |
![]() |
| AF80-22-00-13 1SBL397501R1300 ABB AF80-22-00-13 100-250V50/60HZ-DC Contactor | 75 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.