Product successfully added to your shopping cart
1SBL236261R2200
ABB
1
Low-voltage industrial components > Power contactor, AC switching
Contactors and overload relays > AF contactors to 38 A
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100220C0201 |
| Instructions and Manuals | 1SBC101027M6801 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 101 mm |
| Product Net Height | 86 mm |
| Product Net Weight | 0.41 kg |
| Technical | |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Control Circuit 50 / 60 Hz |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 45 A |
| (690 V) 60 °C 40 A | |
| (690 V) 70 °C 32 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 21.2 A |
| (440 V) 60 °C 20 A | |
| (500 V) 60 °C 17.6 A | |
| (690 V) 60 °C 10.5 A | |
| (380 / 400 V) 60 °C 22 A | |
| (220 / 230 / 240 V) 60 °C 23.2 A | |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 45 A |
| (110 V) 2 Poles in Series, 60 °C 40 A | |
| (110 V) 2 Poles in Series, 70 °C 32 A | |
| (110 V) 3 Poles in Series, 40 °C 45 A | |
| (110 V) 3 Poles in Series, 60 °C 40 A | |
| (110 V) 3 Poles in Series, 70 °C 32 A | |
| (110 V) 4 Poles in Series, 40 °C 45 A | |
| (110 V) 4 Poles in Series, 60 °C 40 A | |
| (110 V) 4 Poles in Series, 70 °C 32 A | |
| (220 V) 3 Poles in Series, 40 °C 45 A | |
| (220 V) 3 Poles in Series, 60 °C 40 A | |
| (220 V) 3 Poles in Series, 70 °C 32 A | |
| (220 V) 4 Poles in Series, 40 °C 45 A | |
| (220 V) 4 Poles in Series, 60 °C 40 A | |
| (220 V) 4 Poles in Series, 70 °C 32 A | |
| (72 V) 1-Pole, 40 °C 45 A | |
| (72 V) 1-Pole, 60 °C 40 A | |
| (72 V) 1-Pole, 70 °C 32 A | |
| (72 V) 2 Poles in Series, 40 °C 45 A | |
| (72 V) 2 Poles in Series, 60 °C 40 A | |
| (72 V) 2 Poles in Series, 70 °C 32 A | |
| (72 V) 3 Poles in Series, 40 °C 45 A | |
| (72 V) 3 Poles in Series, 60 °C 40 A | |
| (72 V) 3 Poles in Series, 70 °C 32 A | |
| (72 V) 4 Poles in Series, 40 °C 45 A | |
| (72 V) 4 Poles in Series, 60 °C 40 A | |
| (72 V) 4 Poles in Series, 70 °C 32 A | |
| Rated Operational Power AC-3 (Pe) | (400 V) 11 kW |
| (415 V) 11 kW | |
| (440 V) 11 kW | |
| (500 V) 11 kW | |
| (690 V) 9 kW | |
| (220 / 230 / 240 V) 5.5 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 690 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 48 ... 130 V |
| 60 Hz 48 ... 130 V | |
| DC Operation 48 ... 130 V | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1.6 W |
| at Rated Operating Conditions AC-3 per Pole 0.42 W | |
| Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 ms |
| Between Coil De-energization and NO Contact Opening 11 ... 95 ms | |
| Between Coil Energization and NC Contact Opening 38 ... 90 ms | |
| Between Coil Energization and NO Contact Closing 40 ... 95 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1.5 ... 16 mm² |
| Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm² | |
| Rigid Solid 1/2x 1.5 ... 4 mm² | |
| Rigid Stranded 1/2x 1.5 ... 16 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Rigid Solid 1/2x 1 ... 2.5 mm² | |
| Rigid Stranded 1/2x 1 ... 2.5 mm² | |
| Wire Stripping Length | Control Circuit 10 mm |
| Main Circuit 12 mm | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 | |
| Tightening Torque | Control Circuit 1.2 N·m |
| Main Circuit 2.5 N·m | |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 45 A |
| Connecting Capacity Main Circuit UL/CSA | Rigid Solid 1/2x 16-10 AWG |
| Rigid Stranded 1/2x 16-6 AWG | |
| Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Rigid Stranded 1/2x 18-14 AWG | |
| Tightening Torque UL/CSA | Control Circuit 11 in·lb |
| Main Circuit 22 in·lb | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air -40 ... 70 °C | |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Shock and Vibration Withstand acc. to IEC 61373 | Category 1, Class B |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 153a7921-46cc-4abe-9462-ddbee59e21de France |
| Simplified SCIP | 054ae370-0a37-4e58-97ad-5a334c6c9f97 Greece |
| 08590f0e-2416-4755-a39b-bbc6647a3daa Germany | |
| 1233249e-f976-4113-8e75-a70d3815b9e9 Portugal | |
| 24ddc243-0386-4534-a79c-bc02ca310202 Denmark | |
| 2e88c240-2f4e-45d8-a522-7a001d84af50 Finland | |
| 57b1162d-53f6-4611-86d0-1414b18daa77 Netherlands | |
| 584bb967-23d0-431a-bb92-2857fe17e704 Belgium | |
| 5bca1c43-2eb6-480d-aa6c-dc0d1d224a06 Croatia | |
| 863e1a88-6644-4849-9926-e60404615e54 Estonia | |
| 8bc8a301-c2a1-4985-87c7-ce8bcf1b312c France | |
| 8e13c240-bee9-47fd-9c75-024aad22ad9b Czech Republic | |
| 93ccf08b-8281-458e-bd69-265ff706ac30 Hungary | |
| b1b960c5-122a-404a-a1d5-2c1e19e86601 Spain | |
| b4c72340-9ab6-45c8-b822-6b9278190c72 Norway | |
| c125bcc7-f615-407a-a50f-b827c8e9d7ca Sweden | |
| c464cbf4-59bc-4e5f-86a1-f8e98792ea87 Italy | |
| e1075ca1-25ce-455e-9e8b-59f4360decac Poland | |
| ea6c20c3-3014-43c7-b8fb-0abbb0e18bc9 Bulgaria | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| End Of Life Disassembling Instructions | 1SBC101080M6801 |
| Environmental Product Declaration - EPD | 1SBD250584E4000 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 94.3 % |
| Certificates and Declarations | |
| A2L Certificate – UL | 9AKK108469A4875 |
| 9AKK108469A4879 | |
| CB Certificate | CB_SE-96553 |
| CCC Certificate | CCC_2024010304656668 |
| CQC Certificate | CQC2010010304445623 |
| Declaration of Conformity - CCC | 2020980304001254 |
| Declaration of Conformity - CE | 1SBD250002U1000 |
| Declaration of Conformity - UKCA | 1SBD250033U1000 |
| GOST Certificate | GOST_POCCFR.ME77.B07175.pdf |
| KC Certificate | KC_HW02016-15002C |
| UL Certificate | UL-US-L319322-13-72119002-5 |
| UL-CA-L319322-43-72119002-6 | |
| UL Listing Card | UL_E319322 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 87 mm |
| Package Level 1 Depth / Length | 103 mm |
| Package Level 1 Height | 47 mm |
| Package Level 1 Gross Weight | 0.41 kg |
| Package Level 1 EAN | 3471523124622 |
| Package Level 2 Units | box 18 piece |
| Package Level 2 Width | 250 mm |
| Package Level 2 Depth / Length | 300 mm |
| Package Level 2 Height | 315 mm |
| Package Level 2 Gross Weight | 14.76 kg |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.