1SBL236261R2200 ABB AF26ZB-40-00CONT.TRAC.BOB.48-130VAC-DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBL236261R2200 ABB AF26ZB-40-00CONT.TRAC.BOB.48-130VAC-DC

1SBL236261R2200

ABB

AF26ZB-40-00CONT.TRAC.BOB.48-130VAC-DC

AF26ZB-40-00-22 48-130V50/60HZ-DC Contactor

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays > AF contactors to 38 A

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100220C0201
Instructions and Manuals1SBC101027M6801
Instructions and Manuals (Part 2)1SAC200017M0002
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width45 mm
Product Net Depth / Length101 mm
Product Net Height86 mm
Product Net Weight0.41 kg
Technical
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles4P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 45 A
(690 V) 60 °C 40 A
(690 V) 70 °C 32 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 21.2 A
(440 V) 60 °C 20 A
(500 V) 60 °C 17.6 A
(690 V) 60 °C 10.5 A
(380 / 400 V) 60 °C 22 A
(220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 45 A
(110 V) 2 Poles in Series, 60 °C 40 A
(110 V) 2 Poles in Series, 70 °C 32 A
(110 V) 3 Poles in Series, 40 °C 45 A
(110 V) 3 Poles in Series, 60 °C 40 A
(110 V) 3 Poles in Series, 70 °C 32 A
(110 V) 4 Poles in Series, 40 °C 45 A
(110 V) 4 Poles in Series, 60 °C 40 A
(110 V) 4 Poles in Series, 70 °C 32 A
(220 V) 3 Poles in Series, 40 °C 45 A
(220 V) 3 Poles in Series, 60 °C 40 A
(220 V) 3 Poles in Series, 70 °C 32 A
(220 V) 4 Poles in Series, 40 °C 45 A
(220 V) 4 Poles in Series, 60 °C 40 A
(220 V) 4 Poles in Series, 70 °C 32 A
(72 V) 1-Pole, 40 °C 45 A
(72 V) 1-Pole, 60 °C 40 A
(72 V) 1-Pole, 70 °C 32 A
(72 V) 2 Poles in Series, 40 °C 45 A
(72 V) 2 Poles in Series, 60 °C 40 A
(72 V) 2 Poles in Series, 70 °C 32 A
(72 V) 3 Poles in Series, 40 °C 45 A
(72 V) 3 Poles in Series, 60 °C 40 A
(72 V) 3 Poles in Series, 70 °C 32 A
(72 V) 4 Poles in Series, 40 °C 45 A
(72 V) 4 Poles in Series, 60 °C 40 A
(72 V) 4 Poles in Series, 70 °C 32 A
Rated Operational Power AC-3 (Pe)(400 V) 11 kW
(415 V) 11 kW
(440 V) 11 kW
(500 V) 11 kW
(690 V) 9 kW
(220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
Power Lossat Rated Operating Conditions AC-1 per Pole 1.6 W
at Rated Operating Conditions AC-3 per Pole 0.42 W
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm²
Rigid Solid 1/2x 1.5 ... 4 mm²
Rigid Stranded 1/2x 1.5 ... 16 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 10 mm
Main Circuit 12 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening TorqueControl Circuit 1.2 N·m
Main Circuit 2.5 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 45 A
Connecting Capacity Main Circuit UL/CSARigid Solid 1/2x 16-10 AWG
Rigid Stranded 1/2x 16-6 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAControl Circuit 11 in·lb
Main Circuit 22 in·lb
Environmental
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Shock and Vibration Withstand acc. to IEC 61373Category 1, Class B
Pollution Degree3
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP153a7921-46cc-4abe-9462-ddbee59e21de France
Simplified SCIP054ae370-0a37-4e58-97ad-5a334c6c9f97 Greece
08590f0e-2416-4755-a39b-bbc6647a3daa Germany
1233249e-f976-4113-8e75-a70d3815b9e9 Portugal
24ddc243-0386-4534-a79c-bc02ca310202 Denmark
2e88c240-2f4e-45d8-a522-7a001d84af50 Finland
57b1162d-53f6-4611-86d0-1414b18daa77 Netherlands
584bb967-23d0-431a-bb92-2857fe17e704 Belgium
5bca1c43-2eb6-480d-aa6c-dc0d1d224a06 Croatia
863e1a88-6644-4849-9926-e60404615e54 Estonia
8bc8a301-c2a1-4985-87c7-ce8bcf1b312c France
8e13c240-bee9-47fd-9c75-024aad22ad9b Czech Republic
93ccf08b-8281-458e-bd69-265ff706ac30 Hungary
b1b960c5-122a-404a-a1d5-2c1e19e86601 Spain
b4c72340-9ab6-45c8-b822-6b9278190c72 Norway
c125bcc7-f615-407a-a50f-b827c8e9d7ca Sweden
c464cbf4-59bc-4e5f-86a1-f8e98792ea87 Italy
e1075ca1-25ce-455e-9e8b-59f4360decac Poland
ea6c20c3-3014-43c7-b8fb-0abbb0e18bc9 Bulgaria
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
End Of Life Disassembling Instructions1SBC101080M6801
Environmental Product Declaration - EPD1SBD250584E4000
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 94.3 %
Certificates and Declarations
A2L Certificate – UL9AKK108469A4875
9AKK108469A4879
CB CertificateCB_SE-96553
CCC CertificateCCC_2024010304656668
CQC CertificateCQC2010010304445623
Declaration of Conformity - CCC2020980304001254
Declaration of Conformity - CE1SBD250002U1000
Declaration of Conformity - UKCA1SBD250033U1000
GOST CertificateGOST_POCCFR.ME77.B07175.pdf
KC CertificateKC_HW02016-15002C
UL CertificateUL-US-L319322-13-72119002-5
UL-CA-L319322-43-72119002-6
UL Listing CardUL_E319322
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width87 mm
Package Level 1 Depth / Length103 mm
Package Level 1 Height47 mm
Package Level 1 Gross Weight0.41 kg
Package Level 1 EAN3471523124622
Package Level 2 Unitsbox 18 piece
Package Level 2 Width250 mm
Package Level 2 Depth / Length300 mm
Package Level 2 Height315 mm
Package Level 2 Gross Weight14.76 kg
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE MOTOR PROTECTION EN.pdf 240 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.