Product successfully added to your shopping cart
AF26-30-00-41
1SBL237001R4100
ABB
1
Low-voltage industrial components > Power contactor, AC switching
Contactors and overload relays > AF contactors to 38 A
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC159659_EPLAN |
| Instructions and Manuals | 1SBC101027M6801 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| Dimensions | |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 86 mm |
| Product Net Height | 86 mm |
| Product Net Weight | 0.31 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Standards | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-16, UL 60947-4-1, CSA C22.2 No. 60947-4-1 |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Control Circuit 50 / 60 Hz |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 45 A |
| (690 V) 60 °C 40 A | |
| (690 V) 70 °C 32 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 26 A |
| (440 V) 60 °C 26 A | |
| (500 V) 60 °C 23 A | |
| (690 V) 60 °C 17 A | |
| (380 / 400 V) 60 °C 26 A | |
| (220 / 230 / 240 V) 60 °C 26 A | |
| Rated Operational Current AC-3e (Ie) | (415 V) 60 °C 26 A |
| (440 V) 60 °C 26 A | |
| (500 V) 60 °C 23 A | |
| (690 V) 60 °C 17 A | |
| (380 / 400 V) 60 °C 26 A | |
| (220 / 230 / 240 V) 60 °C 26 A | |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 45 A |
| (110 V) 2 Poles in Series, 60 °C 40 A | |
| (110 V) 2 Poles in Series, 70 °C 32 A | |
| (110 V) 3 Poles in Series, 40 °C 45 A | |
| (110 V) 3 Poles in Series, 60 °C 40 A | |
| (110 V) 3 Poles in Series, 70 °C 32 A | |
| (220 V) 3 Poles in Series, 40 °C 45 A | |
| (220 V) 3 Poles in Series, 60 °C 40 A | |
| (220 V) 3 Poles in Series, 70 °C 32 A | |
| (72 V) 1-Pole, 40 °C 45 A | |
| (72 V) 1-Pole, 60 °C 40 A | |
| (72 V) 1-Pole, 70 °C 32 A | |
| (72 V) 2 Poles in Series, 40 °C 45 A | |
| (72 V) 2 Poles in Series, 60 °C 40 A | |
| (72 V) 2 Poles in Series, 70 °C 32 A | |
| (72 V) 3 Poles in Series, 40 °C 45 A | |
| (72 V) 3 Poles in Series, 60 °C 40 A | |
| (72 V) 3 Poles in Series, 70 °C 32 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 45 A |
| (110 V) 2 Poles in Series, 60 °C 40 A | |
| (110 V) 2 Poles in Series, 70 °C 32 A | |
| (110 V) 3 Poles in Series, 40 °C 45 A | |
| (110 V) 3 Poles in Series, 60 °C 40 A | |
| (110 V) 3 Poles in Series, 70 °C 32 A | |
| (220 V) 3 Poles in Series, 40 °C 45 A | |
| (220 V) 3 Poles in Series, 60 °C 40 A | |
| (220 V) 3 Poles in Series, 70 °C 32 A | |
| (72 V) 1-Pole, 40 °C 45 A | |
| (72 V) 1-Pole, 60 °C 40 A | |
| (72 V) 1-Pole, 70 °C 32 A | |
| (72 V) 2 Poles in Series, 40 °C 45 A | |
| (72 V) 2 Poles in Series, 60 °C 40 A | |
| (72 V) 2 Poles in Series, 70 °C 32 A | |
| (72 V) 3 Poles in Series, 40 °C 45 A | |
| (72 V) 3 Poles in Series, 60 °C 40 A | |
| (72 V) 3 Poles in Series, 70 °C 32 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 45 A |
| (110 V) 2 Poles in Series, 60 °C 40 A | |
| (110 V) 2 Poles in Series, 70 °C 32 A | |
| (110 V) 3 Poles in Series, 40 °C 45 A | |
| (110 V) 3 Poles in Series, 60 °C 40 A | |
| (110 V) 3 Poles in Series, 70 °C 32 A | |
| (220 V) 3 Poles in Series, 40 °C 20 A | |
| (220 V) 3 Poles in Series, 60 °C 20 A | |
| (220 V) 3 Poles in Series, 70 °C 20 A | |
| (72 V) 1-Pole, 40 °C 20 A | |
| (72 V) 1-Pole, 60 °C 20 A | |
| (72 V) 1-Pole, 70 °C 20 A | |
| (72 V) 2 Poles in Series, 40 °C 45 A | |
| (72 V) 2 Poles in Series, 60 °C 40 A | |
| (72 V) 2 Poles in Series, 70 °C 32 A | |
| (72 V) 3 Poles in Series, 40 °C 45 A | |
| (72 V) 3 Poles in Series, 60 °C 40 A | |
| (72 V) 3 Poles in Series, 70 °C 32 A | |
| Rated Operational Power AC-3 (Pe) | (400 V) 11 kW |
| (415 V) 11 kW | |
| (440 V) 15 kW | |
| (500 V) 15 kW | |
| (690 V) 15 kW | |
| (380 / 400 V) 11 kW | |
| (220 / 230 / 240 V) 6.5 kW | |
| Rated Operational Power AC-3e (Pe) | (415 V) 11 kW |
| (440 V) 15 kW | |
| (500 V) 15 kW | |
| (690 V) 15 kW | |
| (380 / 400 V) 11 kW | |
| (220 / 230 / 240 V) 6.5 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 690 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| (AC-2 / AC-4) 150 cycles per hour | |
| (AC-3) 1200 cycles per hour | |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 24 ... 60 V |
| 60 Hz 24 ... 60 V | |
| DC Operation - | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1.8 W |
| at Rated Operating Conditions AC-3 per Pole 0.6 W | |
| Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 ms |
| Between Coil De-energization and NO Contact Opening 11 ... 95 ms | |
| Between Coil Energization and NC Contact Opening 38 ... 90 ms | |
| Between Coil Energization and NO Contact Closing 40 ... 95 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1.5 ... 10 mm² |
| Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² | |
| Flexible with Insulated Ferrule 2x 1.5 ... 4 mm² | |
| Rigid Solid 1/2x 2.5 ... 4 mm² | |
| Rigid Stranded 1/2x 2.5 ... 10 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Rigid Solid 1/2x 1 ... 2.5 mm² | |
| Rigid Stranded 1/2x 1 ... 2.5 mm² | |
| Wire Stripping Length | Control Circuit 10 mm |
| Main Circuit 14 mm | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 | |
| Tightening Torque | Control Circuit 1.2 N·m |
| Main Circuit 2.5 N·m | |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| NEMA Size | 1 |
| Continuous Current Rating NEMA | 27 A |
| Horsepower Rating NEMA | (115 V AC) Single Phase 2 Hp |
| (200 V AC) Three Phase 7-1/2 Hp | |
| (230 V AC) Single Phase 3 Hp | |
| (230 V AC) Three Phase 7-1/2 Hp | |
| (460 V AC) Three Phase 10 Hp | |
| (575 V AC) Three Phase 10 Hp | |
| General Use Rating UL/CSA | (600 V AC) 45 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 2 hp |
| (200 ... 208 V AC) Three Phase 7-1/2 hp | |
| (220 ... 240 V AC) Three Phase 7-1/2 hp | |
| (240 V AC) Single Phase 3 hp | |
| (440 ... 480 V AC) Three Phase 15 hp | |
| (550 ... 600 V AC) Three Phase 20 hp | |
| Connecting Capacity Main Circuit UL/CSA | Rigid Solid 1/2x 14-10 AWG |
| Rigid Stranded 1/2x 14-8 AWG | |
| Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Rigid Stranded 1/2x 18-14 AWG | |
| Tightening Torque UL/CSA | Control Circuit 11 in·lb |
| Main Circuit 22 in·lb | |
| Full Load Amps Motor Use | (120 V AC) Single Phase 24 A |
| (200 ... 208 V AC) Three Phase 25.3 A | |
| (220 ... 240 V AC) Three Phase 22 A | |
| (240 V AC) Single Phase 17 A | |
| (440 ... 480 V AC) Three Phase 21 A | |
| (550 ... 600 V AC) Three Phase 22 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C |
| Close to Contactor without Thermal O/L Relay -40 ... 70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: B1 25 g |
| Open, Shock Direction: B1 5 g | |
| Shock Direction: A 30 g | |
| Shock Direction: B2 15 g | |
| Shock Direction: C1 25 g | |
| Shock Direction: C2 25 g | |
| Resistance to Vibrations | 4g Closed Position & 2g Open position 5 ... 300 Hz |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| End Of Life Disassembling Instructions | 1SBC101080M6801 |
| Environmental Product Declaration - EPD | 1SBD250584E4000 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 94.3 % |
| Certificates and Declarations | |
| ABS Certificate | ABS_20-2060694-PDA |
| BV Certificate | BV_2634H24898C0 |
| CB Certificate | CB_SE-116364 |
| CCC Certificate | CCC_2024010304656668 |
| CQC Certificate | CQC2010010304445623 |
| CQC2020010304294316 | |
| Declaration of Conformity - CCC | 2020980304001254 |
| 2020980304001052 | |
| Declaration of Conformity - CE | 1SBD250000U1000 |
| Declaration of Conformity - UKCA | 1SBD250031U1000 |
| DNV Certificate | DNV_TAE00001AF-4 |
| GOST Certificate | GOST_POCCFR.ME77.B07175.pdf |
| KC Certificate | KC_HW02016-15001C |
| LR Certificate | LRS_LR23403517TA-02 |
| RINA Certificate | RINA_ELE142224XG |
| RMRS Certificate | RMRS_1802705280 |
| UL Certificate | UL-US-2150887-5 |
| UL-CA-2142658-5 | |
| UL Listing Card | UL_E312527 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 87 mm |
| Package Level 1 Depth / Length | 87 mm |
| Package Level 1 Height | 47 mm |
| Package Level 1 Gross Weight | 0.31 kg |
| Package Level 1 EAN | 3471523110908 |
| Package Level 2 Units | box 21 piece |
| Package Level 2 Width | 250 mm |
| Package Level 2 Depth / Length | 300 mm |
| Package Level 2 Height | 315 mm |
| Package Level 2 Gross Weight | 13.95 kg |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
| AF26-30-00-41 24-60V50/60HZ Contactor - ABB - AF26-30-00-41 - 1SBL237001R4100 | 99 Kbytes |
![]() |
| AF26-30-00-41 1SBL237001R4100 ABB AF26-30-00-41 24-60V50/60HZ Contactor | 79 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.