Product successfully added to your shopping cart
1SDA101669R1
ABB
1
XT7S M 1600 Ekip Touch LSI In1600A 4p FF
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2358 |
| Environmental Product Declaration - EPD | 9AKK108468A1896 |
| 9AKK108468A4411 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 790dbd17-14b1-45fa-9c79-648df13a7208 Italy |
| Simplified SCIP | e44a5f0c-eec2-4d26-b431-2b390c648e2c Czech Republic |
| f1deaee8-a054-4bad-ba66-38e84efaf2e0 Hungary | |
| 5db61fdc-e828-4aa8-825e-9209d10b6dcc Bulgaria | |
| e44a5f0c-eec2-4d26-b431-2b390c648e2c Czech Republic | |
| e2c5669b-c304-4ed5-a13a-22ec6f8b7e2d Netherlands | |
| 3352c0f5-cd2c-49c7-b7be-7ab7be290872 Croatia | |
| 8fa20e8f-2e30-4654-80d6-f3ce37b1a67c Portugal | |
| bdb34083-175a-4240-9586-400c401b1a03 Germany | |
| 03a07972-d64e-497b-bec9-6f0c40a9b6f0 France | |
| 3cfe7d09-cfb5-42f2-9b34-fe7df221a5c7 Poland | |
| 7b6ac1fe-1888-44dd-b124-74042cd3463f Estonia | |
| 77aecd9e-fa30-4662-bf7b-36002a07167d Hungary | |
| f1deaee8-a054-4bad-ba66-38e84efaf2e0 Hungary | |
| 7b6ac1fe-1888-44dd-b124-74042cd3463f Estonia | |
| ca62b12b-0808-4930-b43e-089fe27faf8e Sweden | |
| dba483c8-e490-486b-bd2c-4712be4b475f Germany | |
| d125ea2f-9d19-4bc2-8a46-0db7a69231ce Poland | |
| 64110f0b-13a4-4226-ba98-2daa848ea119 France | |
| 18792fe1-803a-42b3-af02-a183a11fa385 Sweden | |
| 5e66ee19-bedf-4e03-bf27-e03bacf35b30 Belgium | |
| 77aecd9e-fa30-4662-bf7b-36002a07167d Hungary | |
| bdb34083-175a-4240-9586-400c401b1a03 Germany | |
| 03a07972-d64e-497b-bec9-6f0c40a9b6f0 France | |
| caf5b272-deb8-4dac-8c75-49397fea149a Spain | |
| 2f4048ee-915b-4c1d-8f7c-261d36ee5730 Poland | |
| caf5b272-deb8-4dac-8c75-49397fea149a Spain | |
| 8896365b-a656-48cc-b3ac-7206b201cb5e Finland | |
| 8d1b0666-6100-4d5a-9866-415d99614de3 Belgium | |
| 5e66ee19-bedf-4e03-bf27-e03bacf35b30 Belgium | |
| c23d95a5-90fc-4310-b54b-56ee705da517 Norway | |
| 3e52ecaf-129d-47be-b6b1-53a37bafc67b Germany | |
| 8819f3f6-632e-4b0b-9bd2-966879fe1300 Denmark | |
| 64110f0b-13a4-4226-ba98-2daa848ea119 France | |
| c23d95a5-90fc-4310-b54b-56ee705da517 Norway | |
| 8fa20e8f-2e30-4654-80d6-f3ce37b1a67c Portugal | |
| 01060d3d-fa6e-41ac-bf32-72336ec8bbad Greece | |
| 3cfe7d09-cfb5-42f2-9b34-fe7df221a5c7 Poland | |
| ebd770b8-1841-474f-8b6c-544b6834c78f Germany | |
| 5db61fdc-e828-4aa8-825e-9209d10b6dcc Bulgaria | |
| 1efab6d8-ae5d-4425-bdb9-6a5e12330c0d Germany | |
| 8896365b-a656-48cc-b3ac-7206b201cb5e Finland | |
| 8d1b0666-6100-4d5a-9866-415d99614de3 Belgium | |
| 3e52ecaf-129d-47be-b6b1-53a37bafc67b Germany | |
| ebd770b8-1841-474f-8b6c-544b6834c78f Germany | |
| 18792fe1-803a-42b3-af02-a183a11fa385 Sweden | |
| ca62b12b-0808-4930-b43e-089fe27faf8e Sweden | |
| e2c5669b-c304-4ed5-a13a-22ec6f8b7e2d Netherlands | |
| 1efab6d8-ae5d-4425-bdb9-6a5e12330c0d Germany | |
| dba483c8-e490-486b-bd2c-4712be4b475f Germany | |
| d125ea2f-9d19-4bc2-8a46-0db7a69231ce Poland | |
| 2f4048ee-915b-4c1d-8f7c-261d36ee5730 Poland | |
| 8819f3f6-632e-4b0b-9bd2-966879fe1300 Denmark | |
| 3352c0f5-cd2c-49c7-b7be-7ab7be290872 Croatia | |
| 01060d3d-fa6e-41ac-bf32-72336ec8bbad Greece | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XSEMEFAZZAAAA00000 |
| E-Number (Norway) | 4380900 |
| EAN | 8056221017138 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 178 mm |
| Product Net Weight | 12.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 360 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 14 kg |
| Package Level 1 EAN | 8056221017138 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1437 |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 94 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT7M |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1102 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| 1SDH001821A1001 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1600 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 1600 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 16000 A |
| Adjustment range undelayed short-circuit release (EF007131) | 2400.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| 1SDA101669R1 1SDA101669R1 EN_1SDA101669R1.pdf | 605 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.