Product successfully added to your shopping cart
1SDA101465R1
ABB
1
XT7H M 1600 Ekip Hi-Touch LSIG 1600 3pFF
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2358 |
| Environmental Product Declaration - EPD | 9AKK108468A1896 |
| 9AKK108468A4411 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 5ba9d956-90a9-4f4f-991d-5e32e51cac17 Italy |
| Simplified SCIP | addebe28-c3ae-4abe-b4a9-aeb4b4382296 Belgium |
| 27d2769f-ae93-4167-97db-4b16d2620906 Sweden | |
| ef3fe358-972f-4f0a-87e8-7cd927e94c0e Poland | |
| 0120ba40-92d9-4fa5-9cfa-056c46e9b53d France | |
| 163b3ea3-d467-48a3-899e-535379a3c6b5 Sweden | |
| 191e38df-cb69-459f-99b9-03bce1427710 Germany | |
| addebe28-c3ae-4abe-b4a9-aeb4b4382296 Belgium | |
| a648e1fe-782f-4fc2-9ee2-3f5fc92dd274 Spain | |
| 09100df8-c6f9-4d51-8923-8b104589f9f5 Estonia | |
| 453798f9-8757-4bb4-a43c-e9c189cb78f2 Hungary | |
| d962b027-3e8b-4711-87ba-3dd331d71154 Poland | |
| a9b3191b-da57-4cb3-b0f9-2481ebf33b0e France | |
| 09100df8-c6f9-4d51-8923-8b104589f9f5 Estonia | |
| 217abefd-582b-4c9a-bd9f-2be393aa5e75 Hungary | |
| 0b2be19d-5033-4e67-a4db-88d48bf1a888 Germany | |
| a9b3191b-da57-4cb3-b0f9-2481ebf33b0e France | |
| 453798f9-8757-4bb4-a43c-e9c189cb78f2 Hungary | |
| a648e1fe-782f-4fc2-9ee2-3f5fc92dd274 Spain | |
| 797eea0a-96f9-4fe1-84bb-a7c946510d22 Denmark | |
| c3b0ec81-a3a3-4cce-a174-6508d49e089f Bulgaria | |
| 396d4862-84a2-4178-9321-9d8aaa1c7e1e Germany | |
| 02fc545d-cd72-4a8e-9424-5370239b0a1a Germany | |
| add8d35e-c44a-4884-bce0-0c2d221bdc63 Belgium | |
| 9a866678-bce4-4ca4-8570-ee1a2d69fc3e Norway | |
| add8d35e-c44a-4884-bce0-0c2d221bdc63 Belgium | |
| 02fc545d-cd72-4a8e-9424-5370239b0a1a Germany | |
| ae8f9f72-b85a-431a-8ae0-e8f738b73793 Finland | |
| 797eea0a-96f9-4fe1-84bb-a7c946510d22 Denmark | |
| ee8026f8-b3bf-4405-b5b6-748094ef6594 Poland | |
| 185e806d-86d3-4005-8e38-e0ceacf4c302 Czech Republic | |
| 09d954a8-dfcd-4e0b-9719-ad1c8393432b Germany | |
| ef3fe358-972f-4f0a-87e8-7cd927e94c0e Poland | |
| 27d2769f-ae93-4167-97db-4b16d2620906 Sweden | |
| 5e40c1ee-3224-4da4-84b1-233dceaa9114 Netherlands | |
| ae8f9f72-b85a-431a-8ae0-e8f738b73793 Finland | |
| 396d4862-84a2-4178-9321-9d8aaa1c7e1e Germany | |
| d3bcd028-b082-4d92-9abf-64d3ba1b866b Greece | |
| 9a866678-bce4-4ca4-8570-ee1a2d69fc3e Norway | |
| 5521c9bb-586a-4962-af3c-3cdc8075ff7b Croatia | |
| 0120ba40-92d9-4fa5-9cfa-056c46e9b53d France | |
| e81f6f5b-cadb-4d5d-b550-0d58ef242a83 Portugal | |
| 5521c9bb-586a-4962-af3c-3cdc8075ff7b Croatia | |
| 0b2be19d-5033-4e67-a4db-88d48bf1a888 Germany | |
| 185e806d-86d3-4005-8e38-e0ceacf4c302 Czech Republic | |
| 5e40c1ee-3224-4da4-84b1-233dceaa9114 Netherlands | |
| c3b0ec81-a3a3-4cce-a174-6508d49e089f Bulgaria | |
| 163b3ea3-d467-48a3-899e-535379a3c6b5 Sweden | |
| 191e38df-cb69-459f-99b9-03bce1427710 Germany | |
| 217abefd-582b-4c9a-bd9f-2be393aa5e75 Hungary | |
| e81f6f5b-cadb-4d5d-b550-0d58ef242a83 Portugal | |
| d3bcd028-b082-4d92-9abf-64d3ba1b866b Greece | |
| 09d954a8-dfcd-4e0b-9719-ad1c8393432b Germany | |
| ee8026f8-b3bf-4405-b5b6-748094ef6594 Poland | |
| d962b027-3e8b-4711-87ba-3dd331d71154 Poland | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XHELLFAZZAAAA00000 |
| EAN | 8056221012799 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 178 mm |
| Product Net Weight | 9.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 11.2 kg |
| Package Level 1 EAN | 8056221012799 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1337 |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 94 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 42 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT7M |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1102 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| 1SDH001821A1001 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1600 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 1600 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 16000 A |
| Adjustment range undelayed short-circuit release (EF007131) | 2400.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.