Product successfully added to your shopping cart
1SDA101226R1
ABB
1
XT7L 800 Ekip Dip LS/I In=800A 4p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | bd22b9c8-c715-481f-8c07-f7ff29a919e4 Italy |
| Simplified SCIP | 3f5f74d7-4d65-459d-ba40-6dd09e9ba6ff Poland |
| c940bbf1-ee6a-434f-a06a-227d366bfa0c Hungary | |
| 2e51ec90-637c-477c-86b3-5181cdb2a5ff Finland | |
| dd3d8cc4-d12e-446f-9e09-1dc5df70004a France | |
| cd8b0d49-e590-43fc-87bf-7094d8c46b57 Germany | |
| d9322576-2c54-4e5d-b969-881d01cae732 Croatia | |
| ec88d46d-3ddd-4ab2-9af0-5999ccc36762 Estonia | |
| cc8a5d5e-4768-457d-8c5c-2afee6563e36 Czech Republic | |
| e7b73761-b5b1-49ad-b24b-e962122bbe26 Germany | |
| 342afc31-e626-45c2-b714-dd57e369fb7e Germany | |
| 5983712b-10a8-4619-8036-1d085d37ed7d Belgium | |
| 545e022f-1e1c-4866-95b7-d64c71dc47c2 Spain | |
| 9fd91ed2-f74a-4181-ab31-d12d0b39eb4d Hungary | |
| 888ee27d-c7e5-4a11-a363-64ba614ba607 Poland | |
| 8d469a29-04fa-4fd2-8aa3-fcce58977bf9 Sweden | |
| 59554a97-05d1-4a98-9415-6c79b8aeb97b Norway | |
| 10f56257-9959-426c-9245-3c7b2271b910 Poland | |
| d37d7df8-80dd-44e3-9516-2d7efad6286d Bulgaria | |
| d8ef98f9-2b9a-4ce9-b9d9-4e9bafcb56f2 Netherlands | |
| 2510d393-78f9-4bf8-b994-91b9f43e290f Germany | |
| c1dd57ef-377b-4748-af6d-6a977068ebf5 Greece | |
| e0f328cc-e763-49e2-81cb-e79befb65782 Germany | |
| 496e64e8-e762-4cba-9a47-bda870bdbccb Denmark | |
| b8ae83f6-8cb6-4d24-bfff-403b84b58b94 Sweden | |
| c157bf03-5b71-423c-8fd2-1708ca0258c2 Portugal | |
| 57f477d1-4434-468a-b383-1ed098299d72 France | |
| d334a6dc-a5e7-4fdc-8383-e7870279ef3a Belgium | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7LE480CEFF000XXX |
| E-Number (Norway) | 4380861 |
| EAN | 8056221015295 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 12.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 360 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 14 kg |
| Package Level 1 EAN | 8056221015295 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1390 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 24 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (240 V AC) 200 kA | |
| (380 V AC) 120 kA | |
| (415 V AC) 120 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 65 kA | |
| (690 V AC) 50 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (240 V AC) 200 kA | |
| (380 V AC) 120 kA | |
| (415 V AC) 120 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 65 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | L |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 800 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 320.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 800 A |
| Adjustment range undelayed short-circuit release (EF007131) | 800 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| 1SDA101226R1 1SDA101226R1 EN_1SDA101226R1.pdf | 658 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.