Product successfully added to your shopping cart
1SDA100925R1
ABB
1
XT7H 1600 Ekip Hi-Touch LSIG 1600A 3p FF
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 9f66f13b-ab7e-44d6-aa9a-e87cd15eb62f Italy |
| Simplified SCIP | 614f39e5-5fa4-47c8-9081-c6345fa03602 Croatia |
| 80c8a959-be50-47cd-ba22-bf53a8ca6bf6 Germany | |
| cf989be6-12ba-475b-b2bc-57380a5422e2 Hungary | |
| 889ca38d-eccc-4079-b449-b5aa8d021426 Germany | |
| 1eabc1df-6b3d-44d8-8053-ab6f11c5f734 Portugal | |
| b897bd4f-ad10-4d1d-bc7e-c3dd95c2d362 Sweden | |
| 7fe95369-69e0-4fce-8973-af90d5ed148b Netherlands | |
| e40349db-3d52-4bc3-b9db-f13a0a6b39e0 Finland | |
| 595bf6b5-ffe9-4e0d-905c-77ecca65f626 Germany | |
| 9acc951b-5b8b-45cd-8274-8bd384067297 Greece | |
| c03a78cf-635f-47a6-a0f2-c2c09a3285f5 Norway | |
| fa7359d2-9340-43f3-9cf2-38fb52057732 France | |
| 614f39e5-5fa4-47c8-9081-c6345fa03602 Croatia | |
| 01e339d4-d278-4122-9575-06a4e8d0bcff Poland | |
| 1886b309-4074-4674-9114-d750282acb05 Germany | |
| 6b2e5ccf-b935-4497-9de4-2d3b8d1be08e Poland | |
| 1eabc1df-6b3d-44d8-8053-ab6f11c5f734 Portugal | |
| 9acc951b-5b8b-45cd-8274-8bd384067297 Greece | |
| 168df824-2531-4e6b-b51a-f5a5f60eeb06 Spain | |
| 9f98bcd8-c00b-4cfd-9a72-9f1124b75095 Hungary | |
| 889ca38d-eccc-4079-b449-b5aa8d021426 Germany | |
| 5c90cc1d-3d86-4be2-af2d-6bc8e4dedb5c France | |
| 168df824-2531-4e6b-b51a-f5a5f60eeb06 Spain | |
| 4b20724b-ff81-4414-ba9e-1abbbb0908df Poland | |
| 921e3871-2767-4b5f-9b85-f754f93d7408 Sweden | |
| 80c8a959-be50-47cd-ba22-bf53a8ca6bf6 Germany | |
| fa7359d2-9340-43f3-9cf2-38fb52057732 France | |
| b897bd4f-ad10-4d1d-bc7e-c3dd95c2d362 Sweden | |
| dc199672-4894-4976-8ceb-1b0ac5fa3972 Czech Republic | |
| 7fe95369-69e0-4fce-8973-af90d5ed148b Netherlands | |
| da20ea82-bb3c-47fb-8db7-87300db5d538 Bulgaria | |
| cf989be6-12ba-475b-b2bc-57380a5422e2 Hungary | |
| 97f0a4ac-297c-4eba-ab11-2937ce5a5978 Estonia | |
| 9f98bcd8-c00b-4cfd-9a72-9f1124b75095 Hungary | |
| 01e339d4-d278-4122-9575-06a4e8d0bcff Poland | |
| 5c90cc1d-3d86-4be2-af2d-6bc8e4dedb5c France | |
| 97f0a4ac-297c-4eba-ab11-2937ce5a5978 Estonia | |
| 677d41c2-2876-443d-acc2-84d670c9409e Belgium | |
| b8483351-bd98-4111-855d-3359ef5ea11d Belgium | |
| e40349db-3d52-4bc3-b9db-f13a0a6b39e0 Finland | |
| 1886b309-4074-4674-9114-d750282acb05 Germany | |
| 2e17999f-2d39-422d-b34f-3574844657c4 Germany | |
| 921e3871-2767-4b5f-9b85-f754f93d7408 Sweden | |
| 6b2e5ccf-b935-4497-9de4-2d3b8d1be08e Poland | |
| 4b20724b-ff81-4414-ba9e-1abbbb0908df Poland | |
| dc199672-4894-4976-8ceb-1b0ac5fa3972 Czech Republic | |
| da37a55f-f3b4-4fc2-939f-a1193acfead7 Denmark | |
| da37a55f-f3b4-4fc2-939f-a1193acfead7 Denmark | |
| 595bf6b5-ffe9-4e0d-905c-77ecca65f626 Germany | |
| da20ea82-bb3c-47fb-8db7-87300db5d538 Bulgaria | |
| 2e17999f-2d39-422d-b34f-3574844657c4 Germany | |
| c03a78cf-635f-47a6-a0f2-c2c09a3285f5 Norway | |
| b8483351-bd98-4111-855d-3359ef5ea11d Belgium | |
| 677d41c2-2876-443d-acc2-84d670c9409e Belgium | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7HE316FUFF000XXX |
| EAN | 8056221009799 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 9.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 11.2 kg |
| Package Level 1 EAN | 8056221009799 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1336 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 94 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 42 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| 1SDH001821A1001 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1600 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 1600 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 16000 A |
| Adjustment range undelayed short-circuit release (EF007131) | 2400.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| 1SDA100925R1 1SDA100925R1 EN_1SDA100925R1.pdf | 541 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.