Product successfully added to your shopping cart
1SDA067772R1
ABB
1
XT2H160 MF R4 Im56 3P F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2348 |
| Environmental Product Declaration - EPD | 9AKK108469A1856 |
| 9AKK108468A1891 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 55.70 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 1dc6a310-6934-476b-ae7a-01b553ee10d7 Italy |
| Simplified SCIP | 16648667-86fa-452e-bbaa-2cce5d4c0503 Germany |
| 3cd79016-6880-4817-b905-22b27da51a7b Norway | |
| ce5c0b30-b450-41f7-9e3c-f797fbcc4e0f Finland | |
| 8138b894-2275-4f75-aea0-788692633ae4 Netherlands | |
| 167fbffc-d583-4678-80fb-f2a3f561bb55 Germany | |
| 7e27380c-1124-4757-b1ca-3dc6ee0e0167 Denmark | |
| 0d83fee6-422d-4f7d-aab7-a270475a6133 Netherlands | |
| 5074dc7d-a027-4bf1-ab29-79cdad30e2ba Estonia | |
| 3048c939-bebd-4f89-b699-405f936911b6 Greece | |
| 50ae6e64-aba8-43ff-9b0c-012c6c825b45 Portugal | |
| 3767c8b5-41e3-4344-9088-63cd289d917d Germany | |
| 3d89592a-4b88-44b7-bd10-b42d18bdf22b Croatia | |
| 9f3ae016-d11f-4123-9fcf-947a068b61e8 Czech Republic | |
| 02f02af5-313a-47d7-ad3a-969e3a297b73 Poland | |
| d5d65095-176f-4371-a94d-70965c023fa0 Netherlands | |
| fe926dee-797c-4de9-93f9-35eaf8cdbe1b Germany | |
| 7fbfff19-137f-4d24-a55c-9dec628964e2 Germany | |
| e759723d-3556-44b3-97f5-a710ad318838 France | |
| 9f058dfd-37cf-4f41-ac3b-a7ae82ff9608 Netherlands | |
| c920c74b-4e01-4252-892e-d792ad087a04 Spain | |
| efea1de7-c2e5-4722-b76e-34c1b59020ee Netherlands | |
| f7262375-560e-4dd3-ab4f-c18e65fc8701 Bulgaria | |
| 1fb7e3d4-acea-4ca2-bdfd-e196e300615a Sweden | |
| af855937-55e1-4436-84bd-87d3ead6da3f Poland | |
| e979ace9-8c22-4611-9f6b-a6030833163c France | |
| e64c283b-002a-458b-95dc-fc12ca10ec9a Sweden | |
| 35783688-f423-4221-9dd6-59acceded38f Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT2HE3004IFF000XXX |
| E-Number (Norway) | 4379384 |
| EAN | 8015644016685 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 90 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 131 mm |
| Package Level 1 Height | 212 mm |
| Package Level 1 Depth / Length | 147 mm |
| Package Level 1 Gross Weight | 1.2 kg |
| Package Level 1 EAN | 8015644016685 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Motor Protection |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1001 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 32.5..100 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 2.47 W |
| Rated Current (In) | 4 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 56 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M6 |
| Release | MF |
| Release Type | M |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT2 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5901 |
| GL Certificate | 1SDL000163R0093 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000721R0100 |
| Mechanical Drawings | 1SDH000721R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000721R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers |
| Object Classification Code | Q |
| UNSPSC | 39121616 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG MOLDED CASE ISOMAX-TMAX 2024 EN.pdf | 71 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.