1SBL921074R8001 ABB AX18-30-01-80 220-230V50Hz 230-240V60Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBL921074R8001 ABB AX18-30-01-80 220-230V50Hz 230-240V60Hz

1SBL921074R8001

ABB

AX18-30-01-80 220-230V50Hz 230-240V60Hz

AX18-30-01-80 220-230V50Hz/230-240V60Hz Contactor

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
EPLAN Data9AAC177926_EPLAN
Data Sheet, Technical Information1SBC100187L0203
Instructions and Manuals9AKK107492A7057
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width44 mm
Product Net Depth / Length74 mm
Product Net Height74 mm
Product Net Weight0.326 kg
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC1
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 28 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(220 / 240 V) 55 °C 25 A
(690 V) 40 °C 27 A
(690 V) 70 °C 20 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 18 A
(440 V) 55 °C 12 A
(500 V) 55 °C 12 A
(690 V) 55 °C 9 A
(380 / 400 V) 55 °C 18 A
(220 / 230 / 240 V) 55 °C 18 A
Rated Operational Current AC-15 (Ie)(500 V) NC 2
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
(400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(110 V) 1.1 A / 121 W
(125 V) 1.1 A / 138 W
(220 V) 0.55 A / 121 W
(250 V) 0.55 A / 138 W
(400 V) 2.8 A / 134 W
(500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)(415 V) 9 kW
(440 V) 5.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(380 / 400 V) 7.5 kW
(220 / 230 / 240 V) 4 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Power Lossat Rated Operating Conditions AC-1 per Pole 1 W
at Rated Operating Conditions AC-3 per Pole 0.2 W
Operate TimeBetween Coil De-energization and NC Contact Closing 9 ... 16 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 21 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening TorqueAuxiliary Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor
Technical UL/CSA
General Use Rating UL/CSA(600 V AC) 30 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 1 hp
(200 ... 208 V AC) Three Phase 5 hp
(220 ... 240 V AC) Three Phase 5 hp
(240 V AC) Single Phase 3 hp
(440 ... 480 V AC) Three Phase 10 hp
(550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use(120 V AC) Single Phase 16 A
(200 ... 208 V AC) Three Phase 17.5 A
(220 ... 240 V AC) Three Phase 15.2 A
(240 V AC) Single Phase 17 A
(440 ... 480 V AC) Three Phase 14 A
(550 ... 600 V AC) Three Phase 17 A
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandaccording to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Simplified SCIP0466a7af-771c-4bff-991e-0c4b675ae92f Croatia
324f14eb-6797-44b1-bd6c-fb77d59f6e61 Sweden
4f958f63-d2f5-452e-afcf-33770ebda302 Spain
62095838-e9aa-4588-a8ef-f2ec9c819233 Germany
62217642-e539-49da-8490-b3cf838d4dba Finland
6bb809a4-87d3-4b5e-961c-ea1d3190037c Estonia
7debf7cc-5344-4082-803f-6b78e4976bcf Denmark
86727e11-fe66-4336-85ea-3264fd0ebd3c Poland
87e60098-4fca-41c4-85bc-4128af98fb58 France
8ce535af-aa08-468b-96e7-4692ed251731 Czech Republic
9cf1dbac-0566-43ea-bb6c-055e607deb39 Netherlands
aacd0a06-c476-41aa-b31e-19683e8a7423 Norway
b0abf0b0-feb4-4169-9f16-d11dc9ed07f7 Portugal
bcff6a2c-c583-4f99-bfe1-716d192b407a Hungary
d2325dc6-c9ed-4dff-bfb9-7245d1a384a1 Greece
d262c641-fc89-4ea0-acac-c729b165954b Belgium
f8f0073b-98dc-441c-9e9f-fbc29cf7b54e Italy
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
CB Certificate9AKK107492A7072
CCC Certificate9AKK107492A7089
CCS CertificateGZ23PTB00147
CQC CertificateCQC2013010304646608
Declaration of Conformity - CCC2020980304001066
Declaration of Conformity - CE1SBD250011U1000
UL CertificateUL_20140702-E312527-10-5
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width48 mm
Package Level 1 Depth / Length78 mm
Package Level 1 Height79 mm
Package Level 1 Gross Weight0.34 kg
Package Level 1 EAN3471522396808
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Finland)3707320

ETIM for 1SBL921074R8001 Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 220 V
Rated control supply voltage AC 60 Hz (EF003979) 230 V
Voltage type for actuating (EF008242) AC
Rated operation current Ie at AC-1, 400 V (EF001393) 27 A
Rated operation current Ie at AC-3, 400 V (EF001392) 18 A
Rated operation power at AC-3, 400 V (EF001364) 7.5 kW
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as normally closed contact (EF001377) 1
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 3

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE MOTOR PROTECTION EN.pdf 240 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.