1SBL411074R8000 ABB AX80-30-00-80 220-230V50Hz 230-240V60Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBL411074R8000 ABB AX80-30-00-80 220-230V50Hz 230-240V60Hz

1SBL411074R8000

ABB

AX80-30-00-80 220-230V50Hz 230-240V60Hz

AX80-30-00-80 220-230V50Hz/230-240V60Hz Contactor

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
EPLAN Data9AAC177932_EPLAN
Data Sheet, Technical Information1SBC100187L0203
Instructions and Manuals9AKK107492A7059
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width70 mm
Product Net Depth / Length110 mm
Product Net Height108 mm
Product Net Weight1.01 kg
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)(220 / 240 V) 55 °C 105 A
(690 V) 40 °C 125 A
(690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 80 A
(440 V) 55 °C 70 A
(500 V) 55 °C 65 A
(690 V) 55 °C 46 A
(380 / 400 V) 55 °C 80 A
(220 / 230 / 240 V) 55 °C 80 A
Rated Operational Power AC-3 (Pe)(415 V) 40 kW
(440 V) 40 kW
(500 V) 45 kW
(690 V) 40 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
(AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Power Lossat Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2 W
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 14 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening TorqueControl Circuit 1 N·m
Main Circuit 4 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor
Technical UL/CSA
General Use Rating UL/CSA(600 V AC) 105 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 7-1/2 hp
(200 ... 208 V AC) Three Phase 25 hp
(220 ... 240 V AC) Three Phase 30 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 60 hp
(550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use(120 V AC) Single Phase 80 A
(200 ... 208 V AC) Three Phase 78.2 A
(220 ... 240 V AC) Three Phase 80 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandaccording to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Simplified SCIP03ac81d5-ab0e-4e9c-bc9b-0a62217000e0 France
1503823e-7ac0-46e5-8f9f-3cd961c1b2de Spain
1bb7ccbc-3977-4e94-8616-2591c33058d8 Portugal
2469f5e3-bfb1-44b2-ada7-a8e91de92352 Netherlands
2a46c045-8482-4c4c-a928-f70ec5d7794f Italy
42b5d1f8-75f0-4553-ad4e-b0529842e474 Poland
4c152294-ddaa-4030-b506-ae25abda3d06 Sweden
4e549b51-fc8c-4fe1-a782-c5be3ec74710 Denmark
4ee34593-11b5-4308-a65b-a8fbacb1c7a2 Hungary
553312ad-bdf1-4b44-a5df-b9acadce6cbc Estonia
5ab7da20-daf2-4700-a22f-e502d7c4cfc1 Croatia
5b2e8ead-17d9-4316-9256-51109c8de892 Finland
6e347705-bbd0-4146-89be-47477ed0026c Germany
7a4d8417-6428-471d-a23a-a21ea12a6517 Belgium
87d4b879-765c-4e4f-8a62-ca2e9d2c598c Czech Republic
c626d9b7-a83a-42e9-8646-02ad1480f306 Norway
efca0723-7031-4466-9230-ff84a2ca5110 Greece
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
CB Certificate9AKK107492A7074
CCC Certificate9AKK107492A7091
CCS CertificateGZ23PTB00147
CQC CertificateCQC2013010304646607
Declaration of Conformity - CCC2020980304001064
Declaration of Conformity - CE1SBD250011U1000
UL CertificateUL_20140702-E312527-10-7
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width102 mm
Package Level 1 Depth / Length143 mm
Package Level 1 Height152 mm
Package Level 1 Gross Weight1.12 kg
Package Level 1 EAN3471522407801
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Finland)3707366

ETIM for 1SBL411074R8000 Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 220 V
Rated control supply voltage AC 60 Hz (EF003979) 230 V
Voltage type for actuating (EF008242) AC
Rated operation current Ie at AC-1, 400 V (EF001393) 125 A
Rated operation current Ie at AC-3, 400 V (EF001392) 80 A
Rated operation power at AC-3, 400 V (EF001364) 37 kW
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as normally closed contact (EF001377) 0
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 3

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE MOTOR PROTECTION EN.pdf 240 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.