1SBL281074R8010 ABB AX32-30-10-80 220-230V50Hz 230-240V60Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBL281074R8010 ABB AX32-30-10-80 220-230V50Hz 230-240V60Hz

1SBL281074R8010

ABB

AX32-30-10-80 220-230V50Hz 230-240V60Hz

AX32-30-10-80 220-230V50Hz/230-240V60Hz Contactor

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
EPLAN Data9AAC177928_EPLAN
Data Sheet, Technical Information1SBC100187L0203
Instructions and Manuals9AKK107492A7057
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width54 mm
Product Net Depth / Length90 mm
Product Net Height108.3 mm
Product Net Weight0.667 kg
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC0
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(220 / 240 V) 55 °C 55 A
(690 V) 40 °C 55 A
(690 V) 70 °C 39 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 32 A
(440 V) 55 °C 32 A
(500 V) 55 °C 28 A
(690 V) 55 °C 21 A
(380 / 400 V) 55 °C 32 A
(220 / 230 / 240 V) 55 °C 32 A
Rated Operational Current AC-15 (Ie)(500 V) NC 2
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
(400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(110 V) 0.55 A / 60 W
(125 V) 1.1 A / 138 W
(220 V) 0.55 A / 121 W
(250 V) 0.55 A / 138 W
(400 V) 2.8 A / 134 W
(500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)(415 V) 15 kW
(440 V) 18.5 kW
(500 V) 18.5 kW
(690 V) 18.5 kW
(380 / 400 V) 15 kW
(220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Power Lossat Rated Operating Conditions AC-1 per Pole 2.5 W
at Rated Operating Conditions AC-3 per Pole 0.9 W
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 14 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 6 ... 18 ms
Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening TorqueAuxiliary Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 2.3 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor
Technical UL/CSA
General Use Rating UL/CSA(600 V AC) 50 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 10 hp
(220 ... 240 V AC) Three Phase 10 hp
(240 V AC) Single Phase 7.5 hp
(440 ... 480 V AC) Three Phase 25 hp
(550 ... 600 V AC) Three Phase 30 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 20 in·lb
Full Load Amps Motor Use(120 V AC) Single Phase 34 A
(200 ... 208 V AC) Three Phase 32.2 A
(220 ... 240 V AC) Three Phase 28 A
(240 V AC) Single Phase 40 A
(440 ... 480 V AC) Three Phase 34 A
(550 ... 600 V AC) Three Phase 32 A
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandaccording to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Simplified SCIP1fa2bf05-8d82-4696-9d67-8ca45d1f6807 Finland
21b2866a-c103-4bcc-b13e-9a79ef47fd9a Hungary
2258c81c-5dba-48dc-92a4-f3345f0dd577 Germany
2874ad5b-104f-4107-b8ac-a4ec89dedb51 Croatia
3f1df392-9ace-44a0-ad36-6f2d094de224 Germany
467c33ce-a571-4ab7-90e3-9ea49ecaa8f9 Poland
572fba3c-0d3d-411a-84e3-0785ab7e7f66 Czech Republic
5a4626c5-d1f8-4c48-9150-a32264a0c112 Denmark
86869519-50f8-41a1-ab4c-02efbc42c380 Estonia
8e1d6f30-eb59-4784-8dc1-a2ac2a56ecd0 Hungary
912ab3a7-3917-4348-8dcb-609b2b6fc350 Sweden
9f6699ed-0aa3-4438-acee-b6e1d8516714 Greece
a5589388-3e31-4a69-b85b-33e11bd8075a Portugal
a7c35f59-a5ee-41e8-9fbf-5c1d616d2518 Belgium
afc1e8c5-35f8-4f9e-a138-9e94dee59fad Belgium
b19d1189-110c-4361-a0c0-e9669be74c1f Italy
b86a8ffe-903d-4d9f-8725-e0eeab4aff5b Norway
dd1e0116-108d-45d9-8c88-77b3f0825240 Spain
f9a0001b-b41a-4f9d-8d76-4b948e94ea91 France
fd766c33-9e6f-490b-aaa0-5a3a783c42a1 Netherlands
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
CB Certificate9AKK107492A7073
CCC Certificate9AKK107492A7090
CCS CertificateGZ23PTB00147
CQC CertificateCQC2013010304647116
Declaration of Conformity - CCC2020980304001065
Declaration of Conformity - CE1SBD250011U1000
UL CertificateUL_20140702-E312527-10-6
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width65 mm
Package Level 1 Depth / Length101 mm
Package Level 1 Height115 mm
Package Level 1 Gross Weight0.71 kg
Package Level 1 EAN3471522399809
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Finland)3707341

ETIM for 1SBL281074R8010 Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 220 V
Rated control supply voltage AC 60 Hz (EF003979) 230 V
Voltage type for actuating (EF008242) AC
Rated operation current Ie at AC-1, 400 V (EF001393) 55 A
Rated operation current Ie at AC-3, 400 V (EF001392) 32 A
Rated operation power at AC-3, 400 V (EF001364) 15 kW
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 0
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 3

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE MOTOR PROTECTION EN.pdf 240 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.