CU30X10 051211 EATON MOELLER 30x10 placa Cu Ver maior
As imagens são só a título ilustrativo. Por favor, consulte a ficha técnica.

CU30X10 051211 EATON MOELLER 30x10 placa Cu

CU30X10

051211

EATON - MOELLER

Disponível

Envio hoje

30x10 placa Cu

Mais detalhes


Armários Distribuição Caixas Involucros Quadros

Enclosures up to 4000 A - EATON - MOELLER

Enclosures accessories - EATON - MOELLER

* Produto novo em sua embalagem original com todas as garantias e certificações de EATON - MOELLER

QuantidadePreço
1+$84.86
3+$81.10
5+$79.73
7+$78.93
9+$78.60
*Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Produtos relacionados

Mais informação



Delivery programme
Product range
  60 mm system
Accessories
  Flat copper bars
Single unit/Complete unit
  Modular system
Description
  Flat copper busbars
Surface finish
  Untreated
Rated operational current
IeCSA630
Length
 mm1500
For use with
  SH1005/4
Cu factor
 kg4,02
Copper busbars
   
Width
 mm30
Height
 mm10
Interval between busbar centres
 mm60
Material
  Copper, non-insulated
Notes 

Calculating material allowance → General information chapter

Selecting the busbar cross-section and the device to be used → Engineering chapter

Technical data
General
Standards
  EN 13061, UL 508
Ambient temperature
   
Operating ambient temperature max.
 °C+35
Interval between busbar centres
 mm60
Contacts
Interval between busbar centres
 mm60
Rated uninterrupted current
  With temperature deviations, DIN 43671 stipulates that a correction factor k2 must be taken into account
Rated uninterrupted current
IuA 
Tu = 35 °C and Ts = 65 °C
   
with 12 x 5 mm bar
IuA200
with 20 x 5 mm busbar
IuA320
with 30 x 5 mm bar
IuA450
with 12 x 10 mm bar
IuA360
with 20 x 10 mm busbar
IuA520
with 30 x 10 mm busbar
IuA630
Electrical data
Rated operational current
IeA630
Material characteristics
Material
  Copper, non-insulated
Surface finish
  Untreated
Notes


For rated uninterrupted current lu of the contact the following applies: according to DIN 43671 correction factor k2 must be taken into account in case of different temperatures.

Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Operating ambient temperature max.
 °C35

Datasheet - PDF

Title:Language:Size:Type:
pdf- Copper busbar, 30x10x1500mm, untreated - EATON - CU30X10 - 51211English103 Kbytespdf- Copper busbar, 30x10x1500mm, untreated - EATON - CU30X10 - 51211