S-PT-1X2-24DC-1/2" 2882569 PHOENIX CONTACT Surge protection in the IP67 screw-on module for measuring sensor.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

S-PT-1X2-24DC-1/2" 2882569 PHOENIX CONTACT Surge protection in the IP67 screw-on module for measuring sensor..

S-PT-1X2-24DC-1/2"

2882569

PHOENIX_CONTACT

Available

Ship on today

Surge protection in the IP67 screw-on module for measuring sensors, direct mounting with 1/2" NPT outer thread, cable gland for the signal cable, two-stage protective circuit. HART-compatible.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$143.59
2+$139.69
3+$137.76
4+$136.53
6+$135.11
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height34 mm
Width34 mm
Depth148 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP67

General

Housing materialZinc die-cast, surface bronzed and nickel-plated
Colorsilver
Standards for cearances and creepage distancesIEC 60664-1
VDE 0110-1
Mounting typect screw connection
TypeScrew-in module
Number of positions3
Direction of actionLine-Line & Line-Earth Ground

Protective circuit

IEC test classificationC1
C2
C3
D1
Nominal voltage UN24 V DC
Maximum continuous voltage UC40 V DC
28 V AC
Maximum continuous voltage UC (wire-wire)40 V DC
28 V AC
Nominal current IN450 mA (55°C)
Operating effective current IC at UC≤ 10 µA
Residual current IPE≤ 2 µA
Nominal discharge current In (8/20) µs (Core-Core)10 kA
Nominal discharge current In (8/20) µs (Core-Earth)10 kA
Nominal discharge current In (8/20) µs (Shield-Earth)10 kA (optional)
Total surge current (8/20) µs20 kA
Total surge current (10/350) µs2 kA
Max. discharge current Imax (8/20) µs maximum (Core-Core)10 kA
Max. discharge current Imax (8/20) µs maximum (Core-Earth)10 kA
Max. discharge current Imax (8/20) µs maximum (Shield-Earth)10 kA
Nominal pulse current Ian (10/1000) µs (Core-Core)23 A
Nominal pulse current Ian (10/1000) µs (Core-Earth)100 A
Nominal pulse current Ian (10/1000) µs (Shield-Earth)100 A
Impulse discharge current (10/350)˽µs, peak value limp1 kA
Output voltage limitation at 1 kV/µs (Core-Core) spike≤ 55 V
Output voltage limitation at 1 kV/µs (Core-Earth) spike≤ 450 V (Direct grounding)
Output voltage limitation at 1 kV/µs (Shield-Earth) spike≤ 600 V (optional)
Output voltage limitation at 1 kV/µs (Core-Core) static≤ 55 V
Output voltage limitation at 1 kV/µs (Core-Earth) static≤ 450 V (Direct grounding)
Residual voltage at In (conductor-conductor)≤ 55 V
Residual voltage with Ian (10/1000)µs (conductor-conductor)≤ 65 V
Voltage protection level Up (core-core)≤ 80 V (C2 -5 kA)
Voltage protection level Up (core-ground)≤ 450 V (C2 -5 kA, direct grounding)
Voltage protection level Up (shield-ground)≤ 600 V (C2 -5 kA optional)
Response time tA (Core-Core)≤ 1 ns
Response time tA (Core-Earth)≤ 100 ns
Response time tA (Shield-Earth)≤ 100 ns
Input attenuation aE, sym.typ. 0.5 dB (≤ 1.5 MHz / 50 Ω)
typ. 0.2 dB (≤ 300 kHz / 150 Ω)
Cut-off frequency fg (3 dB), sym. in 50 Ohm systemtyp. 6 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ohm systemtyp. 2 MHz
Resistance in series2.2 Ω
Surge protection fault messageNone
Max. required back-up fuse500 mA (e.g. T in acc. with IEC 127-2/III)
Impulse durability (conductor-conductor)C2 - 10 kV/5 kA
Impulse durability (conductor-ground)C2 - 10 kV/5 kA
Impulse durability (shield-ground)C2 - 10 kV / 5 kA

Connection data

Connection nameInput/output
Connection methodScrew connection
Connection type INScrew terminal blocks
Connection type OUTConnection line
Connection methodScrew connection
Screw threadM3
Tightening torque0.6 Nm
Stripping length6 mm
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section solid min.0.14 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.16

Standards and Regulations

Standards/regulationsIEC 61643-21

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2882569-S-PT-1X2-24DC-1/2"English118 KbytesPHOENIX CONTACT-2882569-S-PT-1X2-24DC-1/2

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or