MCR-SLP-1-5-UI-0 2814359 PHOENIX CONTACT MCR passive current measuring transducer, for sinusoidal alternatin.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MCR-SLP-1-5-UI-0 2814359 PHOENIX CONTACT MCR passive current measuring transducer, for sinusoidal alternatin..

MCR-SLP-1-5-UI-0

2814359

PHOENIX_CONTACT

Available

Ship on today

MCR passive current measuring transducer, for sinusoidal alternating currents 0..1 A AC/0..5 A AC, without switching output, output signal 0..10 V/0..20 mA

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$150.46
2+$146.42
3+$144.42
4+$143.14
6+$141.86
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Degree of protectionIP20

Input data

InputCurrent measuring input 1 A
Input current range0 A AC ... 1 A AC
Impulse formSine
Overload capacity2 x IN (5 min. at 60°C ambient temperature)
Surge strength50 A (1 s)
Permissible output range1.2 x IN
Nominal frequency fN50 Hz
Frequency measuring range45 Hz ... 60 Hz
Power loss1.6 VA (at IA = 20 mA)
Connection methodScrew connection
InputCurrent measuring input 5 A
Input current range0 A AC ... 5 A AC
Impulse formSine
Overload capacity2 x IN (5 min. at 60°C ambient temperature)
Surge strength100 A (1 s)
Permissible output range1.2 x IN
Nominal frequency fN50 Hz
Frequency measuring range45 Hz ... 60 Hz
Power loss2.2 VA (I = 20 mA)
Connection methodScrew connection

Output data

Output nameVoltage output
Voltage output signal0 V ... 10 V
Max. output voltage20 V
Load/output load voltage output> 100 kΩ
Output nameCurrent output
Current output signal0 mA ... 20 mA
Max. output current30 mA
Load/output load current output< 750 Ω
Residual ripple, in reference to the measured value0.5 % (pp of measured value)

Switching output

Output nameNo switching output

Connection data

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length8 mm
Screw threadM3

General

Maximum transmission error< 0.5 % (of final value)
Maximum temperature coefficient< 0.015 %/K
Step response (10-90%)< 200 ms
Protective circuitTransient protection in the output Suppressor diode
Overvoltage categoryIII
Pollution degree2
Rated insulation voltage300 V AC (to earth)
Test voltage input/output4 kV (50 Hz, 1 min.)
Colorgreen
Housing materialPolyamide PA non-reinforced
Mounting position< 50°C: Any; > 50°C: Vertical (installation on horizontal DIN rail)
ConformanceCE-compliant

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2814359-MCR-SLP-1-5-UI-0English122 KbytesPHOENIX CONTACT-2814359-MCR-SLP-1-5-UI-0

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or