MACX MCR-EX-SL-RPSSI-2I 2865366 PHOENIX CONTACT Repeater power supply View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-EX-SL-RPSSI-2I 2865366 PHOENIX CONTACT Repeater power supply

MACX MCR-EX-SL-RPSSI-2I

2865366

PHOENIX_CONTACT

Repeater power supply

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $476.97
Unit price: $476.97

Quantity Price
1+$476.97
2+$442.14
3+$441.12
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2865366
Packing unit1 pc
Catalog pagePage 141 (C-5-2017)
GTIN4046356160384
Weight per Piece (excluding packing)170.700 g
Custom tariff number85437090
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width12.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.

Input data

Signal inputRepeater power supply operation
Current input signal4 mA ... 20 mA
Transmitter supply voltage> 16 V (20 mA)
> 15.1 V (23 mA)
Underload/overload signal range0 mA ... 24 mA (Extended transmission range for diagnostics)
Polarization and surge protectionYes
Signal inputSignal conditioner operation
Current input signal0 mA ... 20 mA
4 mA ... 20 mA
Voltage dropapprox. 3.9 V (in input isolating amplifier operation)
Underload/overload signal range0 mA ... 24 mA (Extended transmission range for diagnostics)

Output data

Signal outputRepeater power supply operation
Current output signal4 mA ... 20 mA (Output 1 and output 2 active)
Load/output load current output< 450 Ω (20 mA)
< 380 Ω (23 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
≥ 23 mA (Cable short-circuit in the input)
Signal outputSignal conditioner operation
Current output signal0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
Load/output load current output< 450 Ω (20 mA)
< 380 Ω (23 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)

Power supply

Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Max. current consumption< 75 mA (24 V DC / 20 mA)
Power dissipation< 1.45 W (24 V DC/ 20 mA)
Nominal supply voltage range19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Max. current consumption< 46 mA (24 V DC / 20 mA)
Power dissipation< 1.1 W (24 V DC/ 20 mA)

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Connection methodScrew connection
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

General

No. of channels1
Maximum transmission error< 0.1 % (of final value)
Transmission error, typical< 0.05 % (of final value)
Maximum temperature coefficient< 0.01 %/K
Step response (10-90%)1.3 ms (for jump 4 mA ... 20 mA, typical)
Status displayGreen LED (PWR supply voltage)
Flammability rating according to UL 94V0
Electromagnetic compatibilityConformance with EMC directive
Interference emissionEN 61000-6-4
Housing materialPA 6.6-FR
Colorgray
DesignationInput/output/power supply
Electrical isolation300 Vrms(Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationOutput 1/output 2
Electrical isolation1.5 kV AC (50 Hz, 1 min., test voltage)
ConformanceCE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
IECEx[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC T4 Gc
UL, USA/CanadaClass I Div 2; IS for Class I, II, III Div 1
SIL2

Data communication (bypass)

HART functionYes
Protocols supportedHART

Safety data

OperationRepeater power supply operation
Max. output voltage Uo25.2 V
Max. output current Io93 mA
Max. output power Po587 mW
GroupIIC
Max. external inductivity Lo2 mH
Max. external capacity Co107 nF
GroupIIB
Max. external inductivity Lo4 mH
Max. external capacity Co820 nF
Safety-related maximum voltage Um253 V AC (125 V DC)
OperationSignal conditioner operation
Input voltage Ui≤ 30 V
Input current Ii≤ 150 mA
Max. internal inductance Linegligible
Max. internal capacitance Cinegligible

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Flammability rating according to UL 94V0
ConformanceCE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
IECEx[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC T4 Gc
UL, USA/CanadaClass I Div 2; IS for Class I, II, III Div 1
DNV GL-TemperatureB
DNV GL-HumidityB
DNV GL-VibrationA
DNV GL-EMCA
DNV GL-EnclosureRequired protection according to the Rules shall be provided upon installation on board
GroupIIC
IIB

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.