MACX MCR-SL-RPSSI-I 2865955 PHOENIX CONTACT Repeater power supply and input isolating amplifier, HART. Trans.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-SL-RPSSI-I 2865955 PHOENIX CONTACT Repeater power supply and input isolating amplifier, HART. Trans..

MACX MCR-SL-RPSSI-I

2865955

PHOENIX_CONTACT

Available

Ship on today

Repeater power supply and input isolating amplifier, HART. Transfers supplied or active 0/4 - 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 according to IEC 61508.

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$207.97
2+$202.84
3+$200.30
4+$198.73
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width12.5 mm
Height112.5 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Degree of protectionIP20

Input data

Signal inputActive current input
Current input signal4 mA ... 20 mA
Transmitter supply voltage> 21.5 V (20 mA)
> 20.8 V (24 mA)
Signal inputPassive current input
Current input signal0 mA ... 20 mA
4 mA ... 20 mA
Voltage drop< 3.5 V

Output data

Signal outputCurrent output (active and passive)
Current output signal4 mA ... 20 mA (active)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior1:1 to input signal
Load/output load current output< 1000 Ω (20 mA)
< 825 Ω (24 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
≥ 22.5 mA (Cable short-circuit in the input)
Signal outputCurrent output (active and passive)
Current output signal0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
0 mA ... 20 mA (14 ... 26 V ext. source voltage)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior1:1 to input signal
Load/output load current output< 1000 Ω (20 mA)
< 825 Ω (24 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)

Power supply

DesignationRepeater power supply operation
Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%))
Max. current consumption< 76 mA (24 V DC / 20 mA / 1000 )
Power consumption< 1.1 W (24 V DC/ 20 mA)
< 1.8 W (20 mA / 1000 )

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Connection methodScrew connection
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

General

No. of channels1
Maximum transmission error< 0.1 % (of final value)
Transmission error, typical< 0.05 % (of final value)
Maximum temperature coefficient< 0.01 %/K
Step response (10-90%)< 200 µs (for jump 4 mA ... 20 mA, load 600)
< 600 µs (for jump 0 mA ... 20 mA, load 600)
Status displayGreen LED (supply voltage)
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryII
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Housing materialPA 66-FR
Colorgreen
DesignationInput/output/power supply
Electrical isolation300 Vrms (Rated insulation voltage (overvoltage category II; pollution degree 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
ConformanceCE-compliant, additionally EN 61326
ATEXEx II 3 G Ex nA II T4 Gc X
UL, USA / CanadaUL 61010 Listed
UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
Functional Safety (SIL)SIL 2

Data communication (bypass)

HART functionYes
Protocols supportedHART

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2865955-MACX MCR-SL-RPSSI-IEnglish159 KbytesPHOENIX CONTACT-2865955-MACX MCR-SL-RPSSI-I