Axioline digital output terminal, 8 outputs, 24 V DC, 2 A, 2-wier connection method (including bus base module and plugs)

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$110.44
2+$107.22
4+$104.61
6+$103.31
8+$102.63
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.16
Stripping length8 mm

General

Mounting typeDIN rail
Net weight136 g
Note on weight specificationswith connectors and bus base module
Diagnostics messagesShort-circuit / overload of the digital outputs Yes

Interfaces

Fieldbus systemLokalbus
DesignationAxioline F local bus
Connection methodBus base module
Transmission speed100 MBit/s

Axioline potentials

Communications power UBus5 V DC (via bus base module)
Current consumption from UBusmax. 150 mA
Supply of digital output modules UO24 V DC
Current consumption from UOmax. 16 A (Provide external protection; if the total current of 8 A is exceeded, connect the supply at the power connector parallel via both terminal points.)

Digital outputs

Output nameDigital outputs
Connection methodPush-in connection
2-wire
Number of outputs8
Protective circuitShort-circuit protection, overload protection of the outputs Electronic
Output voltage24 V
Nominal output voltage24 V DC
Maximum output current per channel2 A
Maximum output current per module16 A (external fuse)
Nominal load, inductivemax. 48 VA (1.2 H, 12 Ω, at nominal load)
Nominal load, lampmax. 48 W (at nominal voltage)
Nominal load, ohmicmax. 48 W (12 Ω, at nominal load)

Standards and Regulations

Conformity with EMC directivesNoise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B
Test section5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

[email protected]

[email protected] 4.027240404
[email protected] 4.127240404
[email protected] 5.027242204
[email protected] 5.127242604
[email protected] 6.027242604
[email protected] 7.027242604
[email protected] 8.027242604
[email protected] 9.027242604

ETIM

ETIM 3.0EC001599
ETIM 4.0EC001599
ETIM 5.0EC001599

UNSPSC

UNSPSC 6.0143172015
UNSPSC 7.090143201404
UNSPSC 1139121311
UNSPSC 12.0139121311
UNSPSC 13.239121311

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2688381-AXL F DO8/2 2A 1HEnglish188 KbytesPHOENIX CONTACT-2688381-AXL F DO8/2 2A 1H