AXL F DO8/2 2A 1H 2688381 PHOENIX CONTACT Axioline digital output terminal, 8 outputs, 24 V DC, 2 A, 2-wier .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXL F DO8/2 2A 1H 2688381 PHOENIX CONTACT Axioline digital output terminal, 8 outputs, 24 V DC, 2 A, 2-wier ..

AXL F DO8/2 2A 1H

2688381

PHOENIX_CONTACT

Available

Ship on today

Axioline digital output terminal, 8 outputs, 24 V DC, 2 A, 2-wier connection method (including bus base module and plugs)

More details


Programmable Logic Controllers Plcs

AUTOMATION Industrial Automation - PHOENIX CONTACT

I/O systems. Connectors - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+133,56 €
2+129,67 €
4+126,51 €
6+124,95 €
8+124,12 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.16
Stripping length8 mm

General

Mounting typeDIN rail
Net weight136 g
Note on weight specificationswith connectors and bus base module
Diagnostics messagesShort-circuit / overload of the digital outputs Yes

Interfaces

Fieldbus systemLokalbus
DesignationAxioline F local bus
Connection methodBus base module
Transmission speed100 MBit/s

Axioline potentials

Communications power UBus5 V DC (via bus base module)
Current consumption from UBusmax. 150 mA
Supply of digital output modules UO24 V DC
Current consumption from UOmax. 16 A (Provide external protection; if the total current of 8 A is exceeded, connect the supply at the power connector parallel via both terminal points.)

Digital outputs

Output nameDigital outputs
Connection methodPush-in connection
2-wire
Number of outputs8
Protective circuitShort-circuit protection, overload protection of the outputs Electronic
Output voltage24 V
Nominal output voltage24 V DC
Maximum output current per channel2 A
Maximum output current per module16 A (external fuse)
Nominal load, inductivemax. 48 VA (1.2 H, 12 Ω, at nominal load)
Nominal load, lampmax. 48 W (at nominal voltage)
Nominal load, ohmicmax. 48 W (12 Ω, at nominal load)

Standards and Regulations

Conformity with EMC directivesNoise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B
Test section5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

[email protected]

[email protected] 4.027240404
[email protected] 4.127240404
[email protected] 5.027242204
[email protected] 5.127242604
[email protected] 6.027242604
[email protected] 7.027242604
[email protected] 8.027242604
[email protected] 9.027242604

ETIM

ETIM 3.0EC001599
ETIM 4.0EC001599
ETIM 5.0EC001599

UNSPSC

UNSPSC 6.0143172015
UNSPSC 7.090143201404
UNSPSC 1139121311
UNSPSC 12.0139121311
UNSPSC 13.239121311

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2688381-AXL F DO8/2 2A 1HEnglish188 KbytesPHOENIX CONTACT-2688381-AXL F DO8/2 2A 1H

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review