Analog extension module with 4 analog current inputs (0/4 mA ... 20 mA), with screw connection, incl. DIN rail connector

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$412.66
2+$404.57
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width17.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 70 °C (>55°C derating)
-40 °F ... 158 °F (>131°F derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
-40 °F ... 185 °F
Permissible humidity (operation)20 % ... 85 %
Permissible humidity (storage/transport)20 % ... 85 %
Altitude2000 m
Vibration (operation)in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz
Shock16g, 11 ms

General

Overvoltage categoryII
Mounting positionany
Assembly instructionson standard DIN rail NS 35 in accordance with EN 60715
Degree of pollution2
Housing materialPA 6.6-FR
Flammability rating according to UL 94V0
MTTF771 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
351 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
136 Years (Telcordia standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))

Supply

Supply voltage range19.2 V DC ... 30.5 V DC (DIN rail connector)
Max. current consumption≤ 120 mA (At 24 V DC, at 25°C)
Transient surge protectionYes

Analog inputs

Number of inputs4
Current input signal0 mA ... 20 mA (can be set via DIP switches)
4 mA ... 20 mA (can be set via DIP switches)
Max. current input signal22 mA
Input resistance current input< 70 Ω
Precision≤ 0.02 % (at 25 °C)
Temperature coefficient, typical0.0025 %/K (at -40 °C ... +70 °C)
Supply voltage≥ 12 V DC (For passive sensors (via terminal PWR1, +I1))
Resolution16 (Bit)
Protective circuitShort-circuit and overload protection

Electrical isolation

Analog I/O50 V (Rated insulation voltage (in each case between the TBUS analog outputs / supply, reinforced insulation according to EN 61010))

Test voltage

Analog I/O1.5 kV AC (50 Hz, 1 min.)

Connection data

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Tightening torque0.6 Nm
Screw threadM3

Status indicator

Status displayGreen LED (supply voltage, PWR)
Green LED (bus communication, DAT)
Red LED (periphery error, ERR)

Approvals and conformance

ConformanceCE-compliant
IECExEx nA IIC T4 Gc
UL, USA / CanadaUL 508 Listed
Standard designationEMC Directive 2004/108/EC
Standards/regulationsEN 61000-6-2
Standard designationEMC Directive 2004/108/EC
Standards/regulationsEN 61000-6-4
Standard designationEx Directive (ATEX)
Standards/regulationsEN 60079-0
Standard designationEx Directive (ATEX)
Standards/regulationsEN-60079-15

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Standard designationEMC Directive 2004/108/EC
Standards/regulationsEN 61000-6-2
Standard designationEMC Directive 2004/108/EC
Standards/regulationsEN 61000-6-4
Standard designationEx Directive (ATEX)
Standards/regulationsEN 60079-0
Standard designationEx Directive (ATEX)
Standards/regulationsEN-60079-15
Shock16g, 11 ms
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2
Flammability rating according to UL 94V0
Vibration (operation)in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
IECExEx nA IIC T4 Gc
UL, USA / CanadaUL 508 Listed
Class I, Div. 2, Groups A, B, C, D T4A
Class I, Zone 2, IIC T4

[email protected]

[email protected] 4.027230207
[email protected] 4.127230207
[email protected] 5.027230207
[email protected] 5.127242208
[email protected] 6.027242208
[email protected] 7.027242208
[email protected] 8.027242601

ETIM

ETIM 3.0EC001423
ETIM 4.0EC000310
ETIM 5.0EC001596

UNSPSC

UNSPSC 6.0130211506
UNSPSC 7.090143223108
UNSPSC 1139121008
UNSPSC 12.0143223108
UNSPSC 13.243223108

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2901537-RAD-AI4-IFSEnglish914 KbytesPHOENIX CONTACT-2901537-RAD-AI4-IFS

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or