CP1W-32ET1 274643 OMRON Control System, Expansion Module 32 outputs PNP View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CP1W-32ET1 274643 OMRON Control System, Expansion Module 32 outputs PNP

CP1W-32ET1

274643

OMRON

Available

Ship on today

Control System, Expansion Module 32 outputs PNP

More details


Programmable Logic Controllers Plcs

Programmable logic controllers - Compact PLC - OMRON

Programmable logic controllers - Compact PLC - CP1W/CPM1A expansion units - OMRON

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

QuantityPrice
1+$331.81
2+$324.45
3+$321.86
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



G9SP-N_ Programmable safety system
Standalone safety controller
The G9SP safety controller provides all local safety based in- and outputs and controls the safety application.
• Three CPU-types to suit different applications
• Clear diagnosis and monitring via Ethernet or serial connection
• Memory cassette for easy duplication of configuration
• Unique programming software to support easy design, verfication, standardization and reusage of the program.
• Certified according to PLe (EN ISO 13849-1) and SIL 3 (IEC 61508)
Ordering information
Appearance Appearance description Order code
G9SP configuration
Standalone
10 PNP safety inputs
G9SP-N10S
 Safety controller G9SP
safety controller 4 PNP safety outputs
4 test outputs
4 PNP standard outputs
10 PNP safety inputs
16 PNP safety outputs
6 test outputs
20 PNP safety inputs
8 PNP safety outputs
6 test outputs
Software
G9SP-N10D G9SP-N20S
 Expansion I/O Units
 Memory cassette
 Ethernet option board
 RS-232C option board
 Compact non-contact door switch
 Safety mats
 CJ1/PLC
 Relays with forcibly guided contacts
 Configurator

Appearance Media Applicable OS Order code 
G9SP
Setup disk 1 license Windows 2000
WS02-G9SP01-V1
configurator
Setup disk 10 licenses
Setup disk 50 licenses
Windows XP Windows Vista Windows 7
WS02-G9SP10-V1  

WS02-G9SP50-V1
Setup disk Site license WS02-G9SPXX-V1
Expansion units (standard I/O) 
Appearance Type Number of I/O Model 
In Out
Expansion I/O
unit
Sinking 12 8 (solid state) CP1W-20EDT Sourcing 12 8 (solid state) CP1W-20EDT1
Sinking – 32 (solid state) CP1W-32ET
Sourcing – 32 (solid state) CP1W-32ET1 
I/O Connecting cable, 80 cm long CP1W-CN811 
Option units
Appearance Order code
RS-232 option board CP1W-CIF01
Ethernet option board (Ver. 2.0 or later) CP1W-CIF41
Memory cassette CP1W-ME05M
G9SP Status Display Touchscreen with 1.8 m cable 82614-0010 H-T40M-P
G9SP-N10S Display Kit (G9SP, Touchscreen, cable, CP1W-CIF01) 82612-0010 G9SP-N10S-SDK G9SP-N10D Display Kit (G9SP, Touchscreen, cable, CP1W-CIF01) 82612-0020 G9SP-N10D-SDK G9SP-N20S Display Kit (G9SP, Touchscreen, cable, CP1W-CIF01) 82612-0030 G9SP-N20S-SDK G9SP-N10S kit with EtherNet/IP module 82608-0010 G9SP-N10S-EIP G9SP-N10D kit with EtherNet/IP module 82608-0020 G9SP-N10D-EIP G9SP-N20S kit with EtherNet/IP module 82608-0030 G9SP-N20S-EIP
507
G9SP-N_ Programmable safety system
Specifications
General specifications
Power supply voltage 20.4 to 26.4 VDC
Safety output specifications
Output type Sourcing outputs (PNP)
Consumption
(24 VDC -15% +10%)
G9SP-N10S 400 mA
Rated output current
0.8 A max. per output*
current
(V1: 300 mA, V2: 100 mA)
G9SP-N10D 500 mA
(V1: 300 mA, V2: 200 mA)
G9SP-N20S 500 mA
Residual voltage 1.2 V max. between each output terminal and V2
Test output specifications
Output type Sourcing outputs (PNP)
(V1: 400 mA, V2: 100 mA)
Mounting method 35-mm DIN track
Rated output current
0.3 A max. per output*
Ambient operating temperature 0°C to 55°C Ambient storage temperature –20°C to 75°C Degree of protection IP20 (IEC 60529)
Safety input specifications
Residual voltage 1.2 V max. between each output terminal and V1
Standard output specifications (G9SP-N10S)
Output type Sourcing outputs (PNP)
ON Residual voltage 1.5 V max. (between each output terminal and V2)
Input type Sinking inputs (PNP)
ON voltage 11 VDC min. between each input terminal and G1
Rated output current
100 mA max.*
OFF voltage 5 VDC max. between each input terminal and G1
OFF current 1 mA max.
Input current 6 mA
*For details on the rated output current, please refer to the user manual of G9SP.
Control system integration
Safety - I/O-status becomes transparent
The standalone safety controller offers diagnosis information in 3 ways:
1) via parallel wiring
2) via serial RS232C interface (option)
3) via Ethernet interface (option).
Information of all safety in- and outputs on the standard control system ensure minimum downtime of the machine.
Machine control Safety control
CP1L PLC
I/O wiring
G9SP
Standalone safety controller
Serial RS232C
Ethernet
Safety door switch
Safety light curtain
Contactor
Emergency stop
Contactor
508
G9SP-N_ Programmable safety system
G9SP configuration tool
Easy setup and configuration is provided by a setup wizard supporting the hardware selection.
Designing Reusing
Simulating Packaging
User-defined function blocks
Approved configuration elements such as a tested door monitoring solution can be easily stored as a user defined function block and re-used in future projects. This minimises the time it takes to create a new system configuration.
Integrated Simulator
All functions can be tested and simulated in the Configuration Tool, so there’s no unnecessary additional workload for the engineer. In addition, on-line diagnosis reduces debug time
to a minimum during implementation in the machine control system.
Knowledge-building
Existing configurations are the basis for new projects. The G9SP Configuration Tool supports re-use of existing and proven know-how in safety control, as well as user-defined function blocks. Which means no more repetition of effort, instead a growing library of safety solutions.
509

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643English368 Kbytespdf1-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643
pdf1-CP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643English7 Mbytespdf1-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643
pdf2-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643English2 Mbytespdf1-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643
pdf2-CP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643English4 Mbytespdf1-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643
pdf3-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643English2 Mbytespdf1-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643
pdf3-CP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643English0 bytespdf1-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643
pdf4-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643English2 Mbytespdf1-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643
pdf4-CP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643English0 bytespdf1-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643
pdf5-CP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643English12 Mbytespdf1-mostradoCP1 Expansion unit, 32x PNP outputs 0.3A - OMRON - CP1W-32ET1 - 274643

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or