5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: IB IL 24 PSDOR 4-PAC
Code: 2985864
Manufacturer: PHOENIX CONTACT
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT
LAST VIEWED
The safety module is an output module from the Inline product range, designed for use in an INTERBUS-Safety or PROFIsafe system. The safety module can be used as part of an Inline station at any point within an INTERBUS-Safety or PROFIsafe Inline system.
The transmission speed of the safety module can be set to 500 kbaud or 2 Mbaud using a switch. Only one transmission speed must be used uniformly within a station. The module has four safe digital relay outputs, each with two relay contacts. The outputs can be parameterized according to the application and enable the integration of actuators in the safe INTERBUS system (INTERBUS-Safety) and in the PROFIsafe system.
The safety-related segment circuit can be switched on or off using suitable wiring.
When the output is switched off, the supply to the subsequent modules is disconnected safely.
The module also has two clock outputs with assigned alarm inputs for monitoring external contact extensions.
Depending on the installation and parameterization, in these systems the safety module can achieve the following safety integrity:
– Up to category 4 according to standard EN 954-1
– Up to SIL 3 according to standards EN 61508 and EN 62061
– Up to PL e according to standard EN ISO 13849-1
| Width | 73.2 mm |
|---|---|
| Height | 119.8 mm |
| Depth | 71.5 mm |
| Note on dimensions | Housing dimensions |
| Ambient temperature (operation) | -25 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
| Permissible humidity (operation) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
| Permissible humidity (storage/transport) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
| Air pressure (operation) | 80 kPa ... 108 kPa (up to 2000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above mean sea level) |
| Degree of protection | IP20 |
| Fieldbus system | INTERBUS |
|---|---|
| Designation | Inline local bus |
| Connection method | Inline data jumper |
| Transmission speed | 500 kBit/ / 2 MBit/s (can be switched) |
| Output name | Relay output |
|---|---|
| Connection method | Spring-cage connection |
| 2-wire | |
| Number of outputs | 4 (Safety relays) |
| Output voltage | 24 V DC (US- 1 V) |
| Nominal output voltage | 24 V DC (Inline connector) |
| Output current | max. 4 A (Inline connector, pro contact, observe derating) |
| max. 6 A (COMBICON connector, pro contact, observe derating) | |
| Maximum output current per channel | 4 A |
| Supply voltage | 24 V DC (via voltage jumper) |
|---|---|
| Supply voltage range | 19.2 V DC ... 30 V DC |
| Communications power UL | 7.5 V (via voltage jumper) |
| Current consumption | max. 360 mA (from the local bus) |
| Net weight | 386 g |
|---|---|
| Note on weight specifications | with connectors |
| Mounting type | DIN rail |
| Category according to EN 13849-1 | 4 |
| Communications power UL | 7.5 V DC (see safety data) |
|---|---|
| Current consumption from UL | max. 360 mA |
| Main circuit supply UM | 24 V DC |
| Supply voltage range UM | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption from UM | typ. 30 mA (all outputs set including actuator current) |
| max. 0.03 A | |
| Segment supply voltage US | 24 V |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP