Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: 1SDA104457R1
Manufacturer: ABB
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
LAST VIEWED
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 1289d643-2259-45f9-b3bc-a0717851dbb6 Italy |
| Simplified SCIP | d9561dea-e031-4732-ae9e-94a2d813435b Netherlands |
| 724c7057-ca35-49f8-b43e-aea2dc00e669 Poland | |
| 27c97ce5-7fbf-4d91-bcf5-a5ae7608bdba France | |
| 9ba3a301-500a-40be-bbdb-c24adac26e03 Hungary | |
| b05003be-1e59-468b-a85e-bdf0fcb78d5f Sweden | |
| 78a1add3-586a-495c-841b-b67e2b295b20 Germany | |
| 303e3ca5-7c9d-4930-b93d-59f126cbd995 Germany | |
| b97fdc45-ff27-42d9-89c3-1fbb0d3bcb5d Poland | |
| a6d2ae0a-c13d-475d-93f4-6bd30cd26169 Germany | |
| 52a23916-898c-474a-ab79-556d9b86b8a3 Norway | |
| de73c4ad-a1dd-4879-9589-ebb5881fc845 Poland | |
| cd25e52e-3756-44ba-90b1-b5a217fe9c87 Belgium | |
| 04b99d34-3c1a-4c66-9a96-782fae23c812 Spain | |
| ec9fa878-0d29-4ea2-9755-e765d3338bde France | |
| f67e1f76-47da-45b5-91c8-f1a51d7f72d8 Sweden | |
| 753061d8-2f62-44c7-a831-a80cff5d925e Finland | |
| 1d586d8d-3182-4051-9bc0-40ea8ad15902 Belgium | |
| 35cbb3fd-a64b-4709-8d70-d824b0a7c4d3 Denmark | |
| 6b88df7f-f149-4ca9-9379-cdf25dd8a67c Germany | |
| 782c9a69-82f2-4998-8186-bfab31182195 Germany | |
| 817fae3c-2687-443c-92d3-d106afdced12 Bulgaria | |
| 8e9644c3-9583-49c0-91d3-7ac9661708f4 Portugal | |
| 02e36c43-b506-4927-bd4c-910355da328a Greece | |
| 8f0315b8-0ee0-4a67-80e3-7bf3a7b93215 Croatia | |
| 901eb151-ff2a-442c-8611-20e4ca77d46e Czech Republic | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | 9BSTEKAB000A000000XX |
| EAN | 8015644065379 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 407 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 55 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 59 kg |
| Package Level 1 EAN | 8015644065379 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 900 V 2000 cycle |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 450 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 900 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (800 V AC) 50 kA |
| (900 V AC) 50 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (800 V AC) 50 kA |
| (900 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 900 V |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Remarks | E9 |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 900V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK107680A4888 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP