SIEMENS

A Siemens é uma gigante global em automação industrial e eletrificação, presente em mais de 190 países. Seu catálogo de produtos é o mais extenso do mercado, cobrindo desde distribuição de energia e controle até soluções de fábrica digital. Para o engenheiro eletricista, a Siemens oferece uma gama completa de componentes de controle industrial: ...

7ME6810-2YJ31-3PB2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PB2
Referência: 7ME6810-2YJ31-3PB2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e montagem do transmissor: Versão avançada separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 pinos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ31-3PB3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PB3
Referência: 7ME6810-2YJ31-3PB3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e Montagem do Transmissor: Versão Avançada Separada, Cabo Fixo Do - 30 m (98,4) no Sensor com Conectores IP68/NEMA6P de 6 Pólos Interface de Transferência: Padrão RS 485 com MODBUS RTU (com Terminação de Linha) Alimentação: 12/24 V AC/DC Alimentação com Bateria Reserva e Cabo de Alimentação de 3m (9,8 pés) para Conexão Externa (sem Bateria)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PB4
Referência: 7ME6810-2YJ31-3PB4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e Montagem do Transmissor: Versão Avançada Separada, Cabo Fixo Do - 30 m (98,4) no Sensor com Conectores IP68/NEMA6P de 6 Pólos Interface de Transferência: Padrão RS 485 com MODBUS RTU (com Terminação de Linha) Alimentação: 115 - 230 V AC Alimentação com Bateria de Reserva e Cabo de Alimentação de 3m (9,8 pés) para Conexão Externa (sem Bateria)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PC0
Referência: 7ME6810-2YJ31-3PC0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo de transmissor e montagem: Versão avançada separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Porta serial RS 232 com MODBUS RTU Alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PC1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PC1
Referência: 7ME6810-2YJ31-3PC1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e Montagem do Transmissor: Versão Avançada Separada, Cabo Fixo Do - 30 m (98,4) no Sensor com Conectores IP68/NEMA6P de 6 Pólos Interface de Transferência: Porta Serial RS 232 com MODBUS RTU Alimentação: Bateria Interna Embutida
Envio: Ver disponibilidad
7ME6810-2YJ31-3PC2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PC2
Referência: 7ME6810-2YJ31-3PC2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e montagem do transmissor: Versão avançada separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Porta serial RS 232 com MODBUS RTU Alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ31-3PC3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PC3
Referência: 7ME6810-2YJ31-3PC3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e Montagem do Transmissor: Versão Avançada Separada, Cabo Fixo - 30 m (98,4) no Sensor com Conectores IP68/NEMA6P de 6 Pólos Interface de Transferência: Porta Serial RS 232 com MODBUS RTU Alimentação: Alimentação de 12/24 V AC/DC com bateria de reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PC4
Referência: 7ME6810-2YJ31-3PC4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e Montagem do Transmissor: Versão Avançada Separada, Cabo Fixo Do - 30 m (98,4) no Sensor com Conectores IP68/NEMA6P de 6 Pólos Interface de Transferência: Porta Serial RS 232 com MODBUS RTU Alimentação: 115 - 230 V AC Alimentação com Bateria Reserva e Cabo de Alimentação de 3m (9,8 pés) para Conexão Externa (sem Bateria)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PD0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PD0
Referência: 7ME6810-2YJ31-3PD0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e montagem do transmissor: Versão avançada separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com protocolo Sensus Potência: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PD1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PD1
Referência: 7ME6810-2YJ31-3PD1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e montagem do transmissor: Versão Advanced separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com protocolo Sensus Alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ31-3PD2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PD2
Referência: 7ME6810-2YJ31-3PD2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e montagem do transmissor: Versão Advanced separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com protocolo Sensus Alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ31-3PD3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PD3
Referência: 7ME6810-2YJ31-3PD3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e montagem do transmissor: Versão Advanced separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com protocolo Sensus Alimentação: fonte de alimentação de 12/24 V AC/DC com bateria reserva e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PD4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PD4
Referência: 7ME6810-2YJ31-3PD4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo de Transmissor e Montagem: Versão Avançada Separada, Cabo Fixo Do - 30 m (98,4) no Sensor com Conectores IP68/NEMA6P de 6 Pólos Interface de Transferência: Módulo de Interface do Transmissor para Rádio ITRON 200WP com Protocolo Sensus Potência: 115 - 230 V AC Alimentação com Bateria Reserva e Cabo de Alimentação de 3m (9,8 pés) para Conexão Externa (sem Bateria)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PS0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PS0
Referência: 7ME6810-2YJ31-3PS0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo de transmissor e montagem: Versão avançada separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G / UMTS para MAG8000 com cabo de antena (5m) Alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PS1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PS1
Referência: 7ME6810-2YJ31-3PS1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e montagem do transmissor: Versão avançada separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ31-3PS2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PS2
Referência: 7ME6810-2YJ31-3PS2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo de transmissor e montagem: Versão avançada separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) Alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ31-3PS3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PS3
Referência: 7ME6810-2YJ31-3PS3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e Montagem do Transmissor: Versão Avançada Separada, Cabo Fixo - 30 m (98.4) no Sensor com Conectores IP68/NEMA6P de 6 Polos Módulo MAG8000 3G/UMTS com Cabo de Antena (5m) Alimentação: 12/24V AC/DC Power com Backup de Bateria e Cabo de Alimentação de 3m (9.8 ft) para Conexão Externa (Sem Bateria)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PS4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PS4
Referência: 7ME6810-2YJ31-3PS4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e Montagem do Transmissor: Versão Avançada Separada, Cabo Fixo - 30 m (98.4) no Sensor com Conectores IP68/NEMA6P de 6 Polos Módulo 3G/UMTS para MAG8000 com Cabo de Antena(5m) Alimentação: 115 - 230V AC Power com Bateria de Backup e Cabo de Alimentação de 3m (9.8ft) para Conexão Externa (sem Bateria)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PT0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PT0
Referência: 7ME6810-2YJ31-3PT0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo e montagem do transmissor: Versão Advanced separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PT1
Referência: 7ME6810-2YJ31-3PT1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo de transmissor e montagem: Versão avançada separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ31-3PT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PT2
Referência: 7ME6810-2YJ31-3PT2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo de transmissor e montagem: Versão Advanced separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ31-3PT3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PT3
Referência: 7ME6810-2YJ31-3PT3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo de transmissor e montagem: Versão avançada separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Alimentação: fonte de alimentação de 12/24 V AC/DC com bateria reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ31-3PT4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ31-3PT4
Referência: 7ME6810-2YJ31-3PT4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro Nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 Polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Flange Padrão e Pressão Nominal: ANSI B16.5: Revestimento EPDM Classe 150 e Eléctrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Padrão +/- 0,4% do Valor Medido +/- 2 mm/s Versão Específica Regional: Austrália (ML, l/h, 50 Hz) Tipo de transmissor e montagem: Versão avançada separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Fonte de alimentação: 115 - 230 V AC com bateria reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1AA0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AA0
Referência: 7ME6810-2YJ32-1AA0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2 % dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Em sensores integrados da versão básica Interface de transferência: Nenhum módulo de comunicação adicional instalado Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1AA1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AA1
Referência: 7ME6810-2YJ32-1AA1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2 % dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Em sensores integrados da versão básica Interface de transferência: Nenhum módulo de comunicação adicional instalado Fonte de alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1AA2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AA2
Referência: 7ME6810-2YJ32-1AA2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: Europa (m3, m3/h, 50 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Sensores Interface de Transferência: Nenhum módulo de comunicação adicional instalado Alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1AA3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AA3
Referência: 7ME6810-2YJ32-1AA3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: Europa (m3, m3/h, 50 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Sem módulos de comunicação adicionais instalados Alimentação: Fonte de alimentação de 12/24 V AC/DC com bateria de reserva e cabo de alimentação de 3m (9,8 pés) para ligação externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1AA4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AA4
Referência: 7ME6810-2YJ32-1AA4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: Europa (m3, m3/h, 50 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Sem Módulo de Comunicação Adicional Instalado Fonte de Alimentação: 115 - 230 V AC Alimentação com Bateria de Reserva e Cabo de Alimentação de 3m (9,8 pés) para Ligação Externa (Sem Bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1AS0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AS0
Referência: 7ME6810-2YJ32-1AS0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2 % dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Nos sensores da versão básica integrada Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1AS1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AS1
Referência: 7ME6810-2YJ32-1AS1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2 % dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Em sensores de versão básica integrados Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Fonte de alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1AS2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AS2
Referência: 7ME6810-2YJ32-1AS2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Em sensores de versão básica integrados Módulo 3G / UMTS para MAG8000 com cabo de antena (5m) Alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1AS3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AS3
Referência: 7ME6810-2YJ32-1AS3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Em sensores de versão básica integrados Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Alimentação: fonte de alimentação de 12/24 V AC/DC com bateria reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1AS4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AS4
Referência: 7ME6810-2YJ32-1AS4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Em sensores de versão básica integrados Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Alimentação: 115 - 230 V AC com bateria reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1AT0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AT0
Referência: 7ME6810-2YJ32-1AT0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2 % dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Em sensores da versão básica integrada Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1AT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AT1
Referência: 7ME6810-2YJ32-1AT1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2 % dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Em sensores da versão básica integrada do módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1AT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AT2
Referência: 7ME6810-2YJ32-1AT2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Nos sensores de versão básica integrados Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Fonte de alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1AT3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AT3
Referência: 7ME6810-2YJ32-1AT3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Em sensores de versão básica integrados Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Fonte de alimentação: fonte de alimentação de 12/24 V AC/DC com bateria de reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1AT4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1AT4
Referência: 7ME6810-2YJ32-1AT4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Nos sensores da versão básica integrada Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Fonte de alimentação: alimentação de 115 - 230 V AC com bateria de reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BA0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BA0
Referência: 7ME6810-2YJ32-1BA0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Nenhum módulo de comunicação adicional instalado Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BA1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BA1
Referência: 7ME6810-2YJ32-1BA1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Nenhum módulo de comunicação adicional instalado Fonte de alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1BA2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BA2
Referência: 7ME6810-2YJ32-1BA2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Nenhum módulo de comunicação adicional instalado Fonte de alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1BA3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BA3
Referência: 7ME6810-2YJ32-1BA3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Nenhum módulo de comunicação adicional instalado Fonte de alimentação: Alimentação de 12/24 V CA/CC com backup de bateria e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BA4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BA4
Referência: 7ME6810-2YJ32-1BA4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Nenhum módulo de comunicação adicional instalado Fonte de alimentação: Alimentação de 115 a 230 V CA com bateria reserva e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BB0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BB0
Referência: 7ME6810-2YJ32-1BB0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão regional específica: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BB1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BB1
Referência: 7ME6810-2YJ32-1BB1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão regional específica: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Fonte de alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1BB2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BB2
Referência: 7ME6810-2YJ32-1BB2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão regional específica: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Fonte de alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1BB3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BB3
Referência: 7ME6810-2YJ32-1BB3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão regional específica: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Fonte de alimentação: Alimentação de 12/24 V CA/CC com backup de bateria e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BB4
Referência: 7ME6810-2YJ32-1BB4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão regional específica: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Fonte de alimentação: Alimentação de 115 a 230 V CA com bateria reserva e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BC0
Referência: 7ME6810-2YJ32-1BC0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pinos Interface de transferência: Porta serial RS 232 com MODBUS RTU Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BC1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BC1
Referência: 7ME6810-2YJ32-1BC1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pinos Interface de transferência: Porta serial RS 232 com MODBUS RTU Fonte de alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1BC2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BC2
Referência: 7ME6810-2YJ32-1BC2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pinos Interface de transferência: Porta serial RS 232 com MODBUS RTU Fonte de alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1BC3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BC3
Referência: 7ME6810-2YJ32-1BC3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pinos Interface de transferência: Porta serial RS 232 com MODBUS RTU Fonte de alimentação: Alimentação de 12/24 V CA/CC com backup de bateria e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BC4
Referência: 7ME6810-2YJ32-1BC4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pinos Interface de transferência: Porta serial RS 232 com MODBUS RTU Fonte de alimentação: Alimentação de 115 a 230 V CA com bateria reserva e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BD0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BD0
Referência: 7ME6810-2YJ32-1BD0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com Sensus Protocol Power: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BD1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BD1
Referência: 7ME6810-2YJ32-1BD1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com Sensus Protocol Power: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1BD2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BD2
Referência: 7ME6810-2YJ32-1BD2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com Sensus Protocol Power: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1BD3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BD3
Referência: 7ME6810-2YJ32-1BD3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com Sensus Protocol Power: Alimentação de 12/24 V CA/CC com backup de bateria e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BD4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BD4
Referência: 7ME6810-2YJ32-1BD4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com Sensus Protocol Power: Alimentação de 115 a 230 V CA com bateria reserva e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BS0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BS0
Referência: 7ME6810-2YJ32-1BS0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BS1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BS1
Referência: 7ME6810-2YJ32-1BS1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Fonte de alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1BS2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BS2
Referência: 7ME6810-2YJ32-1BS2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Fonte de alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1BS3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BS3
Referência: 7ME6810-2YJ32-1BS3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Fonte de alimentação: Alimentação de 12/24 V CA/CC com backup de bateria e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BS4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BS4
Referência: 7ME6810-2YJ32-1BS4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Fonte de alimentação: Alimentação de 115 a 230 V CA com bateria reserva e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BT0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BT0
Referência: 7ME6810-2YJ32-1BT0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BT1
Referência: 7ME6810-2YJ32-1BT1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Fonte de alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1BT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BT2
Referência: 7ME6810-2YJ32-1BT2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Fonte de alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1BT3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BT3
Referência: 7ME6810-2YJ32-1BT3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Fonte de alimentação: Alimentação de 12/24 V CA/CC com backup de bateria e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1BT4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1BT4
Referência: 7ME6810-2YJ32-1BT4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo de 5m (16,4 pés) no sensor com conectores IP68/NEMA6P de 6 polos Módulo 3G/UMTS para MAG8000 com cabo de antena (5m) e cabo analógico (2,5m) Fonte de alimentação: Alimentação de 115 a 230 V CA com bateria reserva e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1EB0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1EB0
Referência: 7ME6810-2YJ32-1EB0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1EB1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1EB1
Referência: 7ME6810-2YJ32-1EB1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Fonte de alimentação: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1EB2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1EB2
Referência: 7ME6810-2YJ32-1EB2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Fonte de alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1EB3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1EB3
Referência: 7ME6810-2YJ32-1EB3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Fonte de alimentação: Alimentação de 12/24 V CA/CC com backup de bateria e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1EB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1EB4
Referência: 7ME6810-2YJ32-1EB4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Padrão RS 485 com MODBUS RTU (com terminação de linha) Fonte de alimentação: Alimentação de 115 a 230 V CA com bateria reserva e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1ED0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1ED0
Referência: 7ME6810-2YJ32-1ED0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com Sensus Protocol Power: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-1ED1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1ED1
Referência: 7ME6810-2YJ32-1ED1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com Sensus Protocol Power: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-1ED2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1ED2
Referência: 7ME6810-2YJ32-1ED2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com Sensus Protocol Power: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-1ED3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1ED3
Referência: 7ME6810-2YJ32-1ED3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com Sensus Protocol Power: Alimentação de 12/24 V CA/CC com backup de bateria e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-1ED4 SIEMENS Medidor de água SITRANS FM MAG 8000 DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-1ED4
Referência: 7ME6810-2YJ32-1ED4
Número de catálogo: -
Medidor de água SITRANS FM MAG 8000 DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) Norma de flange e pressão nominal: ANSI B16.5: Classe 150 Revestimento de EPDM e eletrodos Hastelloy, com Revestimento resistente à corrosão da categoria C4 Calibração: Amp. +/- 0,2 % de valores de medida de +/- 2 mm/s DN 50 - 300 (2" - 12") Versão regional específica: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Jo - 30 m (98.4) no sensor com conectores IP68/NEMA6P de 6 pólos Interface de transferência: Módulo de intrfaz de emissor para ITRON 200WP Rádio com Protocolo Sensus Alimentação: 115 - 230 V AC alimentação com backup de bateria e cabo de energia de 3m (9.8 ft) para a conexão externa (sem bateria)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: Europa (m3, m3/h, 50 Hz) Tipo de transmissor e montagem: Versão básica separada, cabo fixo Do - 30 m (98,4) no sensor com conectores IP68/NEMA6P de 6 polos Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com Sensus Protocol Power: Alimentação de 115 a 230 V CA com bateria reserva e cabo de alimentação de 3 m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AA0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AA0
Referência: 7ME6810-2YJ32-2AA0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Nenhum módulo de comunicação adicional instalado Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AA1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AA1
Referência: 7ME6810-2YJ32-2AA1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Sem Módulo de Comunicação Adicional Potência Instalada: Bateria Interna Embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-2AA2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AA2
Referência: 7ME6810-2YJ32-2AA2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Nenhum módulo de comunicação adicional instalado Alimentação: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-2AA3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AA3
Referência: 7ME6810-2YJ32-2AA3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Nenhum módulo de comunicação adicional instalado Alimentação: Fonte de alimentação CA/CC de 12/24 V com bateria reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AA4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AA4
Referência: 7ME6810-2YJ32-2AA4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Nenhum módulo de comunicação adicional instalado Alimentação: 115 - 230 V AC com bateria de reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AB0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AB0
Referência: 7ME6810-2YJ32-2AB0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Padrão RS 485 com MODBUS RTU (com Terminação de Linha) Fonte de Alimentação: Bateria Interna (Bateria Não Incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AB1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AB1
Referência: 7ME6810-2YJ32-2AB1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: RS 485 Padrão com MODBUS RTU (com Terminação de Linha) Fonte de Alimentação: Bateria Interna Embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-2AB2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AB2
Referência: 7ME6810-2YJ32-2AB2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: US (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: RS 485 Padrão com MODBUS RTU (com Terminação de Linha) Alimentação: Bateria externa com patch cord de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-2AB3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AB3
Referência: 7ME6810-2YJ32-2AB3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Padrão RS 485 com MODBUS RTU (com terminação de linha) Alimentação: fonte de alimentação de 12/24 V AC/DC com bateria de reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AB4
Referência: 7ME6810-2YJ32-2AB4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Padrão RS 485 com MODBUS RTU (com Terminação de Linha) Fonte de Alimentação: 115 - 230 V AC Alimentação com Bateria Reserva e Cabo de Alimentação de 3m (9,8 pés) para Ligação Externa (sem Bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AC0
Referência: 7ME6810-2YJ32-2AC0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: EUA (galões, GPM, 60 Hz) Tipo de transmissor e montagem: Em sensores integrados da versão básica Interface de transferência: Porta serial RS 232 com MODBUS RTU Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AC1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AC1
Referência: 7ME6810-2YJ32-2AC1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Porta Serial RS 232 com MODBUS RTU Fonte de Alimentação: Bateria Interna Embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-2AC2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AC2
Referência: 7ME6810-2YJ32-2AC2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: RS 232 Porta Serial com MODBUS RTU Alimentação: Bateria Externa com Cabo de Conexão de 1,5 m (4,9 pés) com Conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-2AC3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AC3
Referência: 7ME6810-2YJ32-2AC3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: EUA (galões, GPM, 60 Hz) Tipo de transmissor e montagem: Em sensores integrados da versão básica Interface de transferência: Porta serial RS 232 com MODBUS RTU Alimentação: fonte de alimentação de 12/24 V AC/DC com bateria reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AC4
Referência: 7ME6810-2YJ32-2AC4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo e Montagem do Transmissor: Na Versão Básica Integrada Interface de Transferência de Sensores: Porta Serial RS 232 com MODBUS RTU Fonte de Alimentação: 115 - 230 V AC Alimentação com Bateria Reserva e Cabo de Alimentação de 3m (9,8 pés) para Conexão Externa (sem Bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AD0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AD0
Referência: 7ME6810-2YJ32-2AD0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: EUA (galões, GPM, 60 Hz) Tipo de transmissor e montagem: Em sensores integrados da versão básica Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com protocolo Sensus Fonte de alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AD1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AD1
Referência: 7ME6810-2YJ32-2AD1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: EUA (galões, GPM, 60 Hz) Tipo de transmissor e montagem: Em sensores integrados da versão básica Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com protocolo Sensus Potência: Bateria interna embutida
Envio: Ver disponibilidad
7ME6810-2YJ32-2AD2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AD2
Referência: 7ME6810-2YJ32-2AD2
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica regional: EUA (galões, GPM, 60 Hz) Tipo de transmissor e montagem: Em sensores integrados da versão básica Interface de transferência: Módulo de interface do transmissor para rádio ITRON 200WP com protocolo Sensus Potência: Bateria externa com cabo de conexão de 1,5 m (4,9 pés) com conectores IP68/NEMA 6P, Bateria não incluída
Envio: Ver disponibilidad
7ME6810-2YJ32-2AD3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AD3
Referência: 7ME6810-2YJ32-2AD3
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Módulo de Interface do Transmissor para Rádio ITRON 200WP com Protocolo Sensus Potência: Fonte de alimentação de 12/24 V AC/DC com bateria de reserva e cabo de alimentação de 3m (9,8 pés) para conexão externa (sem bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AD4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AD4
Referência: 7ME6810-2YJ32-2AD4
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão Específica Regional: EUA (galões, GPM, 60 Hz) Tipo de Transmissor e Montagem: Na Versão Básica Integrada Interface de Transferência de Sensores: Módulo de Interface do Transmissor para Rádio ITRON 200WP com Protocolo Sensus Potência: 115 - 230 V AC Alimentação com Bateria de Reserva e Cabo de Alimentação de 3m (9,8 pés) para Ligação Externa (sem Bateria)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AS0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AS0
Referência: 7ME6810-2YJ32-2AS0
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: EUA (galões, GPM, 60 Hz) Tipo de transmissor e montagem: Nos sensores da versão básica integrada Módulo 3G / UMTS para MAG8000 com cabo de antena (5m) Alimentação: Bateria interna (bateria não incluída)
Envio: Ver disponibilidad
7ME6810-2YJ32-2AS1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Código do fabricante: 7ME6810-2YJ32-2AS1
Referência: 7ME6810-2YJ32-2AS1
Número de catálogo: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN50 / Qmx 63 m3/h(m3), 2 Inch / Qmx 277 GPM(G), DN50 / Qmx 1.512 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Sensor de fluxo eletromagnético operado por bateria, com flange, diâmetro de DN 25 a DN 1200 (de 1" a 48"). Adequado para medição contínua do fluxo volumétrico de líquidos (condutores) para aplicações de água nos setores de coleta, distribuição, faturamento e irrigação. . Diâmetro nominal: DN 50 (2") DN50 / Qmx 63 m3/h(m3), 2 polegadas / Qmx 277 GPM(G), DN50 / Qmx 1.512 ml/d(Ml) Flange Padrão e Classificação de Pressão: ANSI B16.5: Revestimento EPDM Classe 150 e Eletrodos Hastelloy, Revestimento Resistente à Corrosão Categoria C4 Calibração: Amp. +/- 0,2% dos valores medidos +/- 2 mm/s DN 50 - 300 (2" - 12") Versão específica da região: EUA (galões, GPM, 60 Hz) Tipo e montagem do transmissor: Em sensores de versão básica integrados Módulo 3G / UMTS para MAG8000 com cabo de antena(5m) Alimentação: Bateria interna embutida
Envio: Ver disponibilidad

products sitemap

Últimas opiniões dos nossos clientes

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.