Sistemas de pesagem SIWAREX

Os sistemas de pesagem SIWAREX são módulos de alta precisão projetados para integração em ambientes de automação Siemens, como SIMATIC S7-1200, S7-1500 e ET 200SP. Esses sistemas fornecem medição precisa de massa, força e processamento de sinal de células de carga para aplicações industriais exigentes. As principais características técnicas incl...

7MH7115-3AB12-0 SIEMENS Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, de..

SIEMENS

Código do fabricante: 7MH7115-3AB12-0
Referência: 7MH7115-3AB12-0
Número de catálogo: -
Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, densities and fluidity. Aerated style is designed for air slide gravity conveyors. All models come complete with sensing plate. An integrator is required to complete the system. Model: WF250- Aerated style, 500 t/h maximum design capacity Construction: Painted mild steel Sensing plate liner: Polyurethane for model options 500 tph Load cell: 50 Ib Approvals: CE, RCM, CSA/FM Class II, Div. 1, Groups E, F, G and Class III ATEX II 2D, Ex tD A21 IP65 T70 C, CE, RCM, IECEx, Ex tD A21 IP65 T70 C, EAC Ex ATEX II 2D, Ex tD A21 IP65 T70 C, CE, IECEx, Ex tD A21 IP65 T70, EAC Ex 0:Reserve
Medidor de vazão de sólidos a granel SITRANS WF200: Medidor de vazão de impacto para aplicações de baixa ou média capacidade. Precisão mínima ± 1%, capacidade de até 900 t/h (990 STPH). Versão/Modelo: WF250, capacidade nominal 500 t/h máx. Características de construção: Aço macio pintado Revestimento da placa do sensor: para versões de 500 t/h Poliuretano Célula de carga: 50 Ib Aprovações: CSA/FM Classe II, Div. 1, Grupos E, F, G; Classe III; ATEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... + 65 °C; UKEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; IECEx Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; EAC Ex, 0Ex tb IIIC T80 °C Db X; CE, UKCA, RCM.
Envio: Ver disponibilidad
7MH7112-2JD10 SIEMENS SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for u..

SIEMENS

Código do fabricante: 7MH7112-2JD10
Referência: 7MH7112-2JD10
Número de catálogo: -
SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for use with WF330, WF340 and WF350 flowmeters. A flowguide, sensing plate and integrator are required to complete the system. Classification: hazardous CSA, FM Class I Div. 1 Groups C & D;Class II, Gr. E, F & G, Ex nA IIC T6 Gc, ATEX II 2D - Ex tb IIIC T70 C Db IP64,IECEx FMG 13.0016X,Ex nA IIC T6 Gc, Ex TB IIIC T70 C Db IP64,EAC Ex Range (Range spring size/viscosity of damping fluid): D3/3000 Position 3 Gaskets: PTFE Coating, process side only: Epoxy - white/aluminum, external castings only Sensing Head Mounted LVDT Conditioner: not required
Cabeça de detecção SITRANS WFS320: Medidor de vazão de sólidos a granel adequado para aplicações de baixa a média capacidade. Precisão mínima ± 1%, capacidade de até 300 t/h (330 STPH). Classificação: CSA/FM Classe I, Div. 1, Grupos C, D, Classe II, Div. 1, Grupos E, F, G; ATEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; UKEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; ATEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; UKEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; IECEx Ex tb IIIC T70°C Db, Ta = -40°C a +60°C, IP64; IECEx Ex ec IIC T6 Gc, Ta = -40°C a +60°C; EAC Ex Ex tb IIIC T70°C Db X; EAC Ex Ex nA IIC T6 Gc X Faixa: (tamanho da mola/viscosidade do amortecedor líquido) D3/3.000, posição 3. Juntas de vedação: Revestimento de PTFE: (Lado de contato de processo único) Epóxi - branco/alumínio, peças fundidas externas apenas cartão LVDT na cabeça do sensor: Nenhum
Envio: Ver disponibilidad
7MH7115-1AC02-0 SIEMENS Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, de..

SIEMENS

Código do fabricante: 7MH7115-1AC02-0
Referência: 7MH7115-1AC02-0
Número de catálogo: -
Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, densities and fluidity. Aerated style is designed for air slide gravity conveyors. All models come complete with sensing plate. An integrator is required to complete the system. Model: WF200- 500 t/h maximum design capacity Construction: Painted mild steel Sensing plate liner: Polyurethane for model options 900 tph Load cell: Not specified Approvals: CE, RCM, CSA/FM Class II, Div. 1, Groups E, F, G and Class III ATEX II 2D, Ex tD A21 IP65 T70 C, CE, RCM, IECEx, Ex tD A21 IP65 T70 C, EAC Ex ATEX II 2D, Ex tD A21 IP65 T70 C, CE, IECEx, Ex tD A21 IP65 T70, EAC Ex 0:Reserve
Medidor de vazão de sólidos a granel SITRANS WF200: Medidor de vazão de impacto para aplicações de baixa ou média capacidade. Precisão mínima ± 1%, capacidade de até 900 t/h (990 STPH). Versão/Modelo: WF200, capacidade nominal de 500 t/h máx. Características de construção: Aço macio pintado Revestimento da placa do sensor: para versões de 900 t/h Poliuretano Célula de carga: Não especificado (apenas para cotações, pedido impossível) Aprovações: CSA/FM Classe II, Div. 1, Grupos E, F, G; Classe III; ATEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... + 65 °C; UKEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; IECEx Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; EAC Ex, 0Ex tb IIIC T80 °C Db X; CE, UKCA, RCM.
Envio: Ver disponibilidad
7MH7112-2KA10 SIEMENS SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for u..

SIEMENS

Código do fabricante: 7MH7112-2KA10
Referência: 7MH7112-2KA10
Número de catálogo: -
SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for use with WF330, WF340 and WF350 flowmeters. A flowguide, sensing plate and integrator are required to complete the system. Classification: hazardous CSA, FM Class I Div. 1 Groups C & D;Class II, Gr. E, F & G, Ex nA IIC T6 Gc, ATEX II 2D - Ex tb IIIC T70 C Db IP64,IECEx FMG 13.0016X,Ex nA IIC T6 Gc, Ex TB IIIC T70 C Db IP64,EAC Ex Range (Range spring size/viscosity of damping fluid): D4/5000 Position 1 Gaskets: silicone Coating, process side only: Epoxy - white/aluminum, external castings only Sensing Head Mounted LVDT Conditioner: not required
Cabeça de detecção SITRANS WFS320: Medidor de vazão de sólidos a granel adequado para aplicações de baixa a média capacidade. Precisão mínima ± 1%, capacidade de até 300 t/h (330 STPH). Classificação: CSA/FM Classe I, Div. 1, Grupos C, D, Classe II, Div. 1, Grupos E, F, G; ATEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; UKEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; ATEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; UKEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; IECEx Ex tb IIIC T70°C Db, Ta = -40°C a +60°C, IP64; IECEx Ex ec IIC T6 Gc, Ta = -40°C a +60°C; EAC Ex Ex tb IIIC T70°C Db X; EAC Ex Ex nA IIC T6 Gc X Faixa: (tamanho da mola/viscosidade do líquido tampão) D4/5.000, posição 1. Juntas de vedação: Revestimento de silicone: (lado em contato com o processo único.) Epóxi - branco/alumínio, peças fundidas externas apenas cartão LVDT na cabeça do sensor: Nenhum
Envio: Ver disponibilidad
7MH7115-3AB22-0 SIEMENS Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, de..

SIEMENS

Código do fabricante: 7MH7115-3AB22-0
Referência: 7MH7115-3AB22-0
Número de catálogo: -
Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, densities and fluidity. Aerated style is designed for air slide gravity conveyors. All models come complete with sensing plate. An integrator is required to complete the system. Model: WF250- Aerated style, 500 t/h maximum design capacity Construction: Painted mild steel Sensing plate liner: Polyurethane for model options 500 tph Load cell: 100 Ib Approvals: CE, RCM, CSA/FM Class II, Div. 1, Groups E, F, G and Class III ATEX II 2D, Ex tD A21 IP65 T70 C, CE, RCM, IECEx, Ex tD A21 IP65 T70 C, EAC Ex ATEX II 2D, Ex tD A21 IP65 T70 C, CE, IECEx, Ex tD A21 IP65 T70, EAC Ex 0:Reserve
Medidor de vazão de sólidos a granel SITRANS WF200: Medidor de vazão de impacto para aplicações de baixa ou média capacidade. Precisão mínima ± 1%, capacidade de até 900 t/h (990 STPH). Versão/Modelo: WF250, capacidade nominal 500 t/h máx. Características de construção: Aço macio pintado Revestimento da placa do sensor: para versões de 500 t/h Poliuretano Célula de carga: 100 Ib Aprovações: CSA/FM Classe II, Div. 1, Grupos E, F, G; Classe III; ATEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... + 65 °C; UKEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; IECEx Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; EAC Ex, 0Ex tb IIIC T80 °C Db X; CE, UKCA, RCM.
Envio: Ver disponibilidad
7MH7112-2KD10 SIEMENS SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for u..

SIEMENS

Código do fabricante: 7MH7112-2KD10
Referência: 7MH7112-2KD10
Número de catálogo: -
SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for use with WF330, WF340 and WF350 flowmeters. A flowguide, sensing plate and integrator are required to complete the system. Classification: hazardous CSA, FM Class I Div. 1 Groups C & D;Class II, Gr. E, F & G, Ex nA IIC T6 Gc, ATEX II 2D - Ex tb IIIC T70 C Db IP64,IECEx FMG 13.0016X,Ex nA IIC T6 Gc, Ex TB IIIC T70 C Db IP64,EAC Ex Range (Range spring size/viscosity of damping fluid): D4/5000 Position 1 Gaskets: PTFE Coating, process side only: Epoxy - white/aluminum, external castings only Sensing Head Mounted LVDT Conditioner: not required
Cabeça de detecção SITRANS WFS320: Medidor de vazão de sólidos a granel adequado para aplicações de baixa a média capacidade. Precisão mínima ± 1%, capacidade de até 300 t/h (330 STPH). Classificação: CSA/FM Classe I, Div. 1, Grupos C, D, Classe II, Div. 1, Grupos E, F, G; ATEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; UKEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; ATEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; UKEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; IECEx Ex tb IIIC T70°C Db, Ta = -40°C a +60°C, IP64; IECEx Ex ec IIC T6 Gc, Ta = -40°C a +60°C; EAC Ex Ex tb IIIC T70°C Db X; EAC Ex Ex nA IIC T6 Gc X Faixa: (tamanho da mola/viscosidade do líquido tampão) D4/5.000, posição 1. Juntas de vedação: Revestimento de PTFE: (Lado de contato de processo único) Epóxi - branco/alumínio, peças fundidas externas apenas cartão LVDT na cabeça do sensor: Nenhum
Envio: Ver disponibilidad
7MH7115-1AC12-0 SIEMENS Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, de..

SIEMENS

Código do fabricante: 7MH7115-1AC12-0
Referência: 7MH7115-1AC12-0
Número de catálogo: -
Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, densities and fluidity. Aerated style is designed for air slide gravity conveyors. All models come complete with sensing plate. An integrator is required to complete the system. Model: WF200- 500 t/h maximum design capacity Construction: Painted mild steel Sensing plate liner: Polyurethane for model options 900 tph Load cell: 50 Ib Approvals: CE, RCM, CSA/FM Class II, Div. 1, Groups E, F, G and Class III ATEX II 2D, Ex tD A21 IP65 T70 C, CE, RCM, IECEx, Ex tD A21 IP65 T70 C, EAC Ex ATEX II 2D, Ex tD A21 IP65 T70 C, CE, IECEx, Ex tD A21 IP65 T70, EAC Ex 0:Reserve
Medidor de vazão de sólidos a granel SITRANS WF200: Medidor de vazão de impacto para aplicações de baixa ou média capacidade. Precisão mínima ± 1%, capacidade de até 900 t/h (990 STPH). Versão/Modelo: WF200, capacidade nominal de 500 t/h máx. Características de construção: Aço macio pintado Revestimento da placa do sensor: para versões de 900 t/h Poliuretano Célula de carga: 50 Ib Aprovações: CSA/FM Classe II, Div. 1, Grupos E, F, G; Classe III; ATEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... + 65 °C; UKEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; IECEx Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; EAC Ex, 0Ex tb IIIC T80 °C Db X; CE, UKCA, RCM.
Envio: Ver disponibilidad
7MH7112-2LA10 SIEMENS SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for u..

SIEMENS

Código do fabricante: 7MH7112-2LA10
Referência: 7MH7112-2LA10
Número de catálogo: -
SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for use with WF330, WF340 and WF350 flowmeters. A flowguide, sensing plate and integrator are required to complete the system. Classification: hazardous CSA, FM Class I Div. 1 Groups C & D;Class II, Gr. E, F & G, Ex nA IIC T6 Gc, ATEX II 2D - Ex tb IIIC T70 C Db IP64,IECEx FMG 13.0016X,Ex nA IIC T6 Gc, Ex TB IIIC T70 C Db IP64,EAC Ex Range (Range spring size/viscosity of damping fluid): D4/5000 Position 2 Gaskets: silicone Coating, process side only: Epoxy - white/aluminum, external castings only Sensing Head Mounted LVDT Conditioner: not required
Cabeça de detecção SITRANS WFS320: Medidor de vazão de sólidos a granel adequado para aplicações de baixa a média capacidade. Precisão mínima ± 1%, capacidade de até 300 t/h (330 STPH). Classificação: CSA/FM Classe I, Div. 1, Grupos C, D, Classe II, Div. 1, Grupos E, F, G; ATEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; UKEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; ATEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; UKEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; IECEx Ex tb IIIC T70°C Db, Ta = -40°C a +60°C, IP64; IECEx Ex ec IIC T6 Gc, Ta = -40°C a +60°C; EAC Ex Ex tb IIIC T70°C Db X; EAC Ex Ex nA IIC T6 Gc X Faixa: (tamanho da mola/amortecedor de viscosidade líquida) D4/5.000, posição 2. Juntas de vedação: Revestimento de silicone: (lado em contato com o processo único.) Epóxi - branco/alumínio, peças fundidas externas apenas cartão LVDT na cabeça do sensor: Nenhum
Envio: Ver disponibilidad
7MH7115-3AC02-0 SIEMENS Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, de..

SIEMENS

Código do fabricante: 7MH7115-3AC02-0
Referência: 7MH7115-3AC02-0
Número de catálogo: -
Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, densities and fluidity. Aerated style is designed for air slide gravity conveyors. All models come complete with sensing plate. An integrator is required to complete the system. Model: WF250- Aerated style, 500 t/h maximum design capacity Construction: Painted mild steel Sensing plate liner: Polyurethane for model options 900 tph Load cell: Not specified Approvals: CE, RCM, CSA/FM Class II, Div. 1, Groups E, F, G and Class III ATEX II 2D, Ex tD A21 IP65 T70 C, CE, RCM, IECEx, Ex tD A21 IP65 T70 C, EAC Ex ATEX II 2D, Ex tD A21 IP65 T70 C, CE, IECEx, Ex tD A21 IP65 T70, EAC Ex 0:Reserve
Medidor de vazão de sólidos a granel SITRANS WF200: Medidor de vazão de impacto para aplicações de baixa ou média capacidade. Precisão mínima ± 1%, capacidade de até 900 t/h (990 STPH). Versão/Modelo: WF250, capacidade nominal 500 t/h máx. Características de construção: Aço macio pintado Revestimento da placa do sensor: para versões de 900 t/h Poliuretano Célula de carga: Não especificado (apenas para cotações, pedido impossível) Aprovações: CSA/FM Classe II, Div. 1, Grupos E, F, G; Classe III; ATEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... + 65 °C; UKEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; IECEx Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; EAC Ex, 0Ex tb IIIC T80 °C Db X; CE, UKCA, RCM.
Envio: Ver disponibilidad
7MH7112-2LD10 SIEMENS SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for u..

SIEMENS

Código do fabricante: 7MH7112-2LD10
Referência: 7MH7112-2LD10
Número de catálogo: -
SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for use with WF330, WF340 and WF350 flowmeters. A flowguide, sensing plate and integrator are required to complete the system. Classification: hazardous CSA, FM Class I Div. 1 Groups C & D;Class II, Gr. E, F & G, Ex nA IIC T6 Gc, ATEX II 2D - Ex tb IIIC T70 C Db IP64,IECEx FMG 13.0016X,Ex nA IIC T6 Gc, Ex TB IIIC T70 C Db IP64,EAC Ex Range (Range spring size/viscosity of damping fluid): D4/5000 Position 2 Gaskets: PTFE Coating, process side only: Epoxy - white/aluminum, external castings only Sensing Head Mounted LVDT Conditioner: not required
Cabeça de detecção SITRANS WFS320: Medidor de vazão de sólidos a granel adequado para aplicações de baixa a média capacidade. Precisão mínima ± 1%, capacidade de até 300 t/h (330 STPH). Classificação: CSA/FM Classe I, Div. 1, Grupos C, D, Classe II, Div. 1, Grupos E, F, G; ATEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; UKEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; ATEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; UKEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; IECEx Ex tb IIIC T70°C Db, Ta = -40°C a +60°C, IP64; IECEx Ex ec IIC T6 Gc, Ta = -40°C a +60°C; EAC Ex Ex tb IIIC T70°C Db X; EAC Ex Ex nA IIC T6 Gc X Faixa: (tamanho da mola/amortecedor de viscosidade líquida) D4/5.000, posição 2. Juntas de vedação: Revestimento de PTFE: (Lado de contato de processo único) Epóxi - branco/alumínio, peças fundidas externas apenas cartão LVDT na cabeça do sensor: Nenhum
Envio: Ver disponibilidad
7MH7115-1AC22-0 SIEMENS Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, de..

SIEMENS

Código do fabricante: 7MH7115-1AC22-0
Referência: 7MH7115-1AC22-0
Número de catálogo: -
Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, densities and fluidity. Aerated style is designed for air slide gravity conveyors. All models come complete with sensing plate. An integrator is required to complete the system. Model: WF200- 500 t/h maximum design capacity Construction: Painted mild steel Sensing plate liner: Polyurethane for model options 900 tph Load cell: 100 Ib Approvals: CE, RCM, CSA/FM Class II, Div. 1, Groups E, F, G and Class III ATEX II 2D, Ex tD A21 IP65 T70 C, CE, RCM, IECEx, Ex tD A21 IP65 T70 C, EAC Ex ATEX II 2D, Ex tD A21 IP65 T70 C, CE, IECEx, Ex tD A21 IP65 T70, EAC Ex 0:Reserve
Medidor de vazão de sólidos a granel SITRANS WF200: Medidor de vazão de impacto para aplicações de baixa ou média capacidade. Precisão mínima ± 1%, capacidade de até 900 t/h (990 STPH). Versão/Modelo: WF200, capacidade nominal de 500 t/h máx. Características de construção: Aço macio pintado Revestimento da placa do sensor: para versões de 900 t/h Poliuretano Célula de carga: 100 Ib Aprovações: CSA/FM Classe II, Div. 1, Grupos E, F, G; Classe III; ATEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... + 65 °C; UKEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; IECEx Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; EAC Ex, 0Ex tb IIIC T80 °C Db X; CE, UKCA, RCM.
Envio: Ver disponibilidad
7MH7112-2MA10 SIEMENS SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for u..

SIEMENS

Código do fabricante: 7MH7112-2MA10
Referência: 7MH7112-2MA10
Número de catálogo: -
SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for use with WF330, WF340 and WF350 flowmeters. A flowguide, sensing plate and integrator are required to complete the system. Classification: hazardous CSA, FM Class I Div. 1 Groups C & D;Class II, Gr. E, F & G, Ex nA IIC T6 Gc, ATEX II 2D - Ex tb IIIC T70 C Db IP64,IECEx FMG 13.0016X,Ex nA IIC T6 Gc, Ex TB IIIC T70 C Db IP64,EAC Ex Range (Range spring size/viscosity of damping fluid): D4/5000 Position 3 Gaskets: silicone Coating, process side only: Epoxy - white/aluminum, external castings only Sensing Head Mounted LVDT Conditioner: not required
Cabeça de detecção SITRANS WFS320: Medidor de vazão de sólidos a granel adequado para aplicações de baixa a média capacidade. Precisão mínima ± 1%, capacidade de até 300 t/h (330 STPH). Classificação: CSA/FM Classe I, Div. 1, Grupos C, D, Classe II, Div. 1, Grupos E, F, G; ATEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; UKEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; ATEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; UKEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; IECEx Ex tb IIIC T70°C Db, Ta = -40°C a +60°C, IP64; IECEx Ex ec IIC T6 Gc, Ta = -40°C a +60°C; EAC Ex Ex tb IIIC T70°C Db X; EAC Ex Ex nA IIC T6 Gc X Faixa: (tamanho da mola/viscosidade do líquido tampão) D4/5.000, posição 3. Juntas de vedação: Revestimento de silicone: (lado em contato com o processo único.) Epóxi - branco/alumínio, peças fundidas externas apenas cartão LVDT na cabeça do sensor: Nenhum
Envio: Ver disponibilidad
7MH7115-3AC12-0 SIEMENS Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, de..

SIEMENS

Código do fabricante: 7MH7115-3AC12-0
Referência: 7MH7115-3AC12-0
Número de catálogo: -
Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, densities and fluidity. Aerated style is designed for air slide gravity conveyors. All models come complete with sensing plate. An integrator is required to complete the system. Model: WF250- Aerated style, 500 t/h maximum design capacity Construction: Painted mild steel Sensing plate liner: Polyurethane for model options 900 tph Load cell: 50 Ib Approvals: CE, RCM, CSA/FM Class II, Div. 1, Groups E, F, G and Class III ATEX II 2D, Ex tD A21 IP65 T70 C, CE, RCM, IECEx, Ex tD A21 IP65 T70 C, EAC Ex ATEX II 2D, Ex tD A21 IP65 T70 C, CE, IECEx, Ex tD A21 IP65 T70, EAC Ex 0:Reserve
Medidor de vazão de sólidos a granel SITRANS WF200: Medidor de vazão de impacto para aplicações de baixa ou média capacidade. Precisão mínima ± 1%, capacidade de até 900 t/h (990 STPH). Versão/Modelo: WF250, capacidade nominal 500 t/h máx. Características de construção: Aço macio pintado Revestimento da placa do sensor: para versões de 900 t/h Poliuretano Célula de carga: 50 Ib Aprovações: CSA/FM Classe II, Div. 1, Grupos E, F, G; Classe III; ATEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... + 65 °C; UKEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; IECEx Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; EAC Ex, 0Ex tb IIIC T80 °C Db X; CE, UKCA, RCM.
Envio: Ver disponibilidad
7MH7112-2MD10 SIEMENS SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for u..

SIEMENS

Código do fabricante: 7MH7112-2MD10
Referência: 7MH7112-2MD10
Número de catálogo: -
SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for use with WF330, WF340 and WF350 flowmeters. A flowguide, sensing plate and integrator are required to complete the system. Classification: hazardous CSA, FM Class I Div. 1 Groups C & D;Class II, Gr. E, F & G, Ex nA IIC T6 Gc, ATEX II 2D - Ex tb IIIC T70 C Db IP64,IECEx FMG 13.0016X,Ex nA IIC T6 Gc, Ex TB IIIC T70 C Db IP64,EAC Ex Range (Range spring size/viscosity of damping fluid): D4/5000 Position 3 Gaskets: PTFE Coating, process side only: Epoxy - white/aluminum, external castings only Sensing Head Mounted LVDT Conditioner: not required
Cabeça de detecção SITRANS WFS320: Medidor de vazão de sólidos a granel adequado para aplicações de baixa a média capacidade. Precisão mínima ± 1%, capacidade de até 300 t/h (330 STPH). Classificação: CSA/FM Classe I, Div. 1, Grupos C, D, Classe II, Div. 1, Grupos E, F, G; ATEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; UKEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; ATEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; UKEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; IECEx Ex tb IIIC T70°C Db, Ta = -40°C a +60°C, IP64; IECEx Ex ec IIC T6 Gc, Ta = -40°C a +60°C; EAC Ex Ex tb IIIC T70°C Db X; EAC Ex Ex nA IIC T6 Gc X Faixa: (tamanho da mola/viscosidade do líquido tampão) D4/5.000, posição 3. Juntas de vedação: Revestimento de PTFE: (Lado de contato de processo único) Epóxi - branco/alumínio, peças fundidas externas apenas cartão LVDT na cabeça do sensor: Nenhum
Envio: Ver disponibilidad
7MH7115-1AD02-0 SIEMENS Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, de..

SIEMENS

Código do fabricante: 7MH7115-1AD02-0
Referência: 7MH7115-1AD02-0
Número de catálogo: -
Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, densities and fluidity. Aerated style is designed for air slide gravity conveyors. All models come complete with sensing plate. An integrator is required to complete the system. Model: WF200- 500 t/h maximum design capacity Construction: Painted mild steel Sensing plate liner: Alumina ceramic tiles for model options 500 tph Load cell: Not specified Approvals: CE, RCM, CSA/FM Class II, Div. 1, Groups E, F, G and Class III ATEX II 2D, Ex tD A21 IP65 T70 C, CE, RCM, IECEx, Ex tD A21 IP65 T70 C, EAC Ex ATEX II 2D, Ex tD A21 IP65 T70 C, CE, IECEx, Ex tD A21 IP65 T70, EAC Ex 0:Reserve
Medidor de vazão de sólidos a granel SITRANS WF200: Medidor de vazão de impacto para aplicações de baixa ou média capacidade. Precisão mínima ± 1%, capacidade de até 900 t/h (990 STPH). Versão/Modelo: WF200, capacidade nominal de 500 t/h máx. Características de construção: Aço macio pintado Revestimento da placa do sensor: para versões de 500 t/h Ladrilhos cerâmicos de alumina Célula de carga: Não especificado (apenas para cotações, encomenda impossível) Aprovações: CSA/FM Classe II, Div. 1, Grupos E, F, G; Classe III; ATEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... + 65 °C; UKEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; IECEx Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; EAC Ex, 0Ex tb IIIC T80 °C Db X; CE, UKCA, RCM.
Envio: Ver disponibilidad
7MH7112-2NA10 SIEMENS SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for u..

SIEMENS

Código do fabricante: 7MH7112-2NA10
Referência: 7MH7112-2NA10
Número de catálogo: -
SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for use with WF330, WF340 and WF350 flowmeters. A flowguide, sensing plate and integrator are required to complete the system. Classification: hazardous CSA, FM Class I Div. 1 Groups C & D;Class II, Gr. E, F & G, Ex nA IIC T6 Gc, ATEX II 2D - Ex tb IIIC T70 C Db IP64,IECEx FMG 13.0016X,Ex nA IIC T6 Gc, Ex TB IIIC T70 C Db IP64,EAC Ex Range (Range spring size/viscosity of damping fluid): D5/5000 Position 1 Gaskets: silicone Coating, process side only: Epoxy - white/aluminum, external castings only Sensing Head Mounted LVDT Conditioner: not required
Cabeça de detecção SITRANS WFS320: Medidor de vazão de sólidos a granel adequado para aplicações de baixa a média capacidade. Precisão mínima ± 1%, capacidade de até 300 t/h (330 STPH). Classificação: CSA/FM Classe I, Div. 1, Grupos C, D, Classe II, Div. 1, Grupos E, F, G; ATEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; UKEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; ATEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; UKEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; IECEx Ex tb IIIC T70°C Db, Ta = -40°C a +60°C, IP64; IECEx Ex ec IIC T6 Gc, Ta = -40°C a +60°C; EAC Ex Ex tb IIIC T70°C Db X; EAC Ex Ex nA IIC T6 Gc X Faixa: (tamanho da mola/amortecedor de viscosidade líquida) D5/5.000, posição 1. Juntas de vedação: Revestimento de silicone: (lado em contato com o processo único.) Epóxi - branco/alumínio, peças fundidas externas apenas cartão LVDT na cabeça do sensor: Nenhum
Envio: Ver disponibilidad
7MH7115-3AC22-0 SIEMENS Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, de..

SIEMENS

Código do fabricante: 7MH7115-3AC22-0
Referência: 7MH7115-3AC22-0
Número de catálogo: -
Sitrans WF200/WF250 solids flowmeter, Solids flowmeter for various product sizes, densities and fluidity. Aerated style is designed for air slide gravity conveyors. All models come complete with sensing plate. An integrator is required to complete the system. Model: WF250- Aerated style, 500 t/h maximum design capacity Construction: Painted mild steel Sensing plate liner: Polyurethane for model options 900 tph Load cell: 100 Ib Approvals: CE, RCM, CSA/FM Class II, Div. 1, Groups E, F, G and Class III ATEX II 2D, Ex tD A21 IP65 T70 C, CE, RCM, IECEx, Ex tD A21 IP65 T70 C, EAC Ex ATEX II 2D, Ex tD A21 IP65 T70 C, CE, IECEx, Ex tD A21 IP65 T70, EAC Ex 0:Reserve
Medidor de vazão de sólidos a granel SITRANS WF200: Medidor de vazão de impacto para aplicações de baixa ou média capacidade. Precisão mínima ± 1%, capacidade de até 900 t/h (990 STPH). Versão/Modelo: WF250, capacidade nominal 500 t/h máx. Características de construção: Aço macio pintado Revestimento da placa do sensor: para versões de 900 t/h Poliuretano Célula de carga: 100 Ib Aprovações: CSA/FM Classe II, Div. 1, Grupos E, F, G; Classe III; ATEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... + 65 °C; UKEX II 2D Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; IECEx Ex tb IIIC T80 °C Db IP65, Ta = -40 °C ... +65 °C; EAC Ex, 0Ex tb IIIC T80 °C Db X; CE, UKCA, RCM.
Envio: Ver disponibilidad
7MH7112-2ND10 SIEMENS SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for u..

SIEMENS

Código do fabricante: 7MH7112-2ND10
Referência: 7MH7112-2ND10
Número de catálogo: -
SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for use with WF330, WF340 and WF350 flowmeters. A flowguide, sensing plate and integrator are required to complete the system. Classification: hazardous CSA, FM Class I Div. 1 Groups C & D;Class II, Gr. E, F & G, Ex nA IIC T6 Gc, ATEX II 2D - Ex tb IIIC T70 C Db IP64,IECEx FMG 13.0016X,Ex nA IIC T6 Gc, Ex TB IIIC T70 C Db IP64,EAC Ex Range (Range spring size/viscosity of damping fluid): D5/5000 Position 1 Gaskets: PTFE Coating, process side only: Epoxy - white/aluminum, external castings only Sensing Head Mounted LVDT Conditioner: not required
Cabeça de detecção SITRANS WFS320: Medidor de vazão de sólidos a granel adequado para aplicações de baixa a média capacidade. Precisão mínima ± 1%, capacidade de até 300 t/h (330 STPH). Classificação: CSA/FM Classe I, Div. 1, Grupos C, D, Classe II, Div. 1, Grupos E, F, G; ATEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; UKEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; ATEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; UKEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; IECEx Ex tb IIIC T70°C Db, Ta = -40°C a +60°C, IP64; IECEx Ex ec IIC T6 Gc, Ta = -40°C a +60°C; EAC Ex Ex tb IIIC T70°C Db X; EAC Ex Ex nA IIC T6 Gc X Faixa: (tamanho da mola/amortecedor de viscosidade líquida) D5/5.000, posição 1. Juntas de vedação: Revestimento de PTFE: (Lado de contato de processo único) Epóxi - branco/alumínio, peças fundidas externas apenas cartão LVDT na cabeça do sensor: Nenhum
Envio: Ver disponibilidad