Conversor de fibra óptica com diagnóstico óptico integrado, contato de alarme, para sistemas de barramento RS-485 de 2 fios (SUCONET K, Modbus ...) até 500 kBit/s, codificação NRZ, equipamento terminal com interface de fibra óptica (BFOC), 850 nm, para cabos PCF/fibra de vidro (multimodo)

FO converter with integrated optical diagnostics, alarm contact, for RS-485 2-wire bus systems (SUCONET K, Modbus ...) up to 500 kbps, NRZ coding, terminal device with one FO interface (BFOC), 850 nm, for PCF/fiberglass cable (multimode)

Mais detalhes


Material de instalação de redes de telecomunicações DNT / FNT > Conversor de mídia

Segurança e Comunicações

Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT

Preço total: $1,402.39
Preço unitário: $1,402.39
Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Related products

Best sellers

Mais informação



Dados técnicos

Notes
Note on application
Note on applicationOnly for industrial use
Utilization restriction
EMC noteEMC: class A product, see manufacturer's declaration in the download area
Utilization restriction
CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties
Product typeMedia converter
MTTF957 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
426 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
176 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
MTBF272 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
44 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Data management status
Article revision13

Electrical properties
Electrical isolationVCC // RS-485
Maximum power dissipation for nominal condition2.88 W
Test voltage data interface/power supply1.5 kVrms(50 Hz, 1 min.)
Supply
Supply voltage range18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
Nominal supply voltage24 V DC (in acc. with UL)
Typical current consumption120 mA (24 V DC)
Max. current consumption130 mA
≤ 2 A (For operation in a joining station, via the DIN rail connector)

Output data
Switching
Output nameRelay output
Output descriptionAlarm output
Number of outputs1
Maximum switching voltage60 V DC (Resistive Load, General Load)
30 V AC (Resistive load)
42 V AC (peak, resistive load)
Limiting continuous current0.46 A

Connection data
Supply
Connection methodCOMBICON plug-in screw terminal block
Stripping length7.00 mm
Tightening torque0.56 Nm ... 0.79 Nm

Interfaces
Bit distortion, input± 35 % (permitted)
Bit distortion, output< 6.25 %
Bit delay≤ 1 bit
SignalModbus
S-BUS
Suconet K
J-BUS
DATA HIGHWAY
Data: optical FO
No. of channels1
Transmit capacity, minimum-4 dBm (200/230 µm)
-17.6 dBm (50/125 µm)
-14 dBm (62,5/125 µm)
Transmission length incl. 3 dB system reserve2800 m (F-K 200/230 8 dB/km with quick mounting connector)
4200 m (with F-G 50/125 2.5 dB/km)
3300 m (with F-G 62,5/125 3.0 dB/km)
Transmission protocolProtocol-transparent to the RS-485 interface
Connection methodB-FOC (ST®)
Wavelength850 nm
Minimum receiver sensitivity-32.5 dBm (50/125 µm)
-32.5 dBm (62,5/125 µm)
-32.1 dBm (200/230 µm)
Maximum receiver sensitivity-3 dBm (200/230 µm)
Transmission mediumPCF fiber
Multi-mode fiberglass
Data: RS-485 interface, 2-wire
Serial transmission speed4.8/ 9.6/ 19.2/ 38.4/ 57.6/ 75/ 93.75/ 115.2/ 136/ 187.5/ 375/ 500 kbps
Connection methodPluggable screw connection
Transmission length≤ 1200 m (depending on the data rate, with shielded, twisted data cable)
Termination resistor390 Ω (Can be connected)
220 Ω
390 Ω
Single conductor/terminal point, rigid0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible14
Min. AWG conductor cross section, flexible24
Single-wire/terminal point, rigid AWG max.14
Single-wire/terminal point, rigid AWG min.24
Transmission mediumCopper
File format/codingUART (11/10 bit switchable; NRZ), slip-tolerant
Data direction switchingAutomatic control

Dimensions
Width35 mm
Height99 mm
Depth105 mm

Material specifications
Color (Housing)gray (RAL 7042)
Material (Housing)PA 6.6-FR

Cable/line
FO cable
Fiber types200/230 µm
50/125 µm
62.5/125 µm
PCF fiber
Fiberglass

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
≤ 2000 m (Hazardous locations)
Permissible humidity (operation)30 % ... 95 % (non-condensing)

Approvals
CE
CertificateCE-compliant
ATEX
Identification II 3 G Ex ec IIC T4 Gc
CertificateUL 21 ATEX 2550X
NotePlease follow the special installation instructions in the documentation!
ATEX, FO interface
Identification II (2) G [Ex op is Gb] IIC
 II (2) D [Ex op is Db] IIIC
CertificatePTB 06 ATEX 2042 U
NotePlease follow the special installation instructions in the documentation!
IECEx
IdentificationEx ec IIC T4 Gc
CertificateIECEx ULD 21.00013X
UL, USA/Canada
IdentificationClass I, Zone 2, AEx ec IIC T4 Gc
Ex ec IIC T4 Gc X
Class I, Div. 2, Groups A, B, C, D
KC approval for South Korea
CertificateKCC-REI-PCK-FOCVT2708339
Corrosive gas test
IdentificationISA-S71.04-1985 G3 Harsh Group A
Shipbuilding
IdentificationDNV GL
DNV GL data
TemperatureB
HumidityA
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise immunityEN 61000-6-2:2005
Noise emissionEN 55011
Electrostatic discharge
Standards/regulationsEN 61000-4-2
Electrostatic discharge
Contact discharge± 6 kV
Discharge in air± 8 kV
CommentsCriterion B
Electromagnetic HF field
Standards/regulationsEN 61000-4-3
Electromagnetic HF field
Field intensity10 V/m
CommentsCriterion A
Fast transients (burst)
Standards/regulationsEN 61000-4-4
Fast transients (burst)
Input± 2 kV
Signal± 2 kV
CommentsCriterion B
Surge current load (surge)
Standards/regulationsEN 61000-4-5
Surge current load (surge)
Input± 0.5 kV
Signal± 1 kV
CommentsCriterion B
Conducted interference
Standards/regulationsEN 61000-4-6
Conducted interference
CommentsCriterion A
Voltage10 V
Emitted interference
Standards/regulationsEN 55011
CommentsClass A, industrial applications
Criteria
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Standards and regulations
Free from substances that could impair the application of coatingVDMA 24364:2018-05

Mounting
Mounting typeDIN rail mounting

ETIM for 2708339 Dados e telecomunicações (EC001467)
Característica Valor
Ethernet (EF003535) Não
Ethernet rápida (EF003536) Não
Ethernet Gigabit (EF003546) Não
PoE (EF005178) Sim
Tipo de tensão de alimentação (EF002991) DC
Tensão de alimentação DC (intervalo) (EF007534) 18 V
Altura (EF000040) 103.63 mm
Largura (EF000008) 35.2 mm
Profundidade (EF000049) 103.74 mm

Datasheet - PDF

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.