Switch gerenciável 2000, 8 portas RJ45 10/100/1000 MBit/s, Classe B de conformidade PROFINET, Faixa de temperatura estendida

Managed Switch 2000, 8 RJ45 ports 10/100/1000 Mbps, PROFINET Conformance-Class B, Extended temperature range, Development process certified in accordance with IEC 62443-4-1, Compatible with IEC 62443-4-2

Mais detalhes


Material de instalação de redes de telecomunicações DNT / FNT > Interruptor de rede

E / S

Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT

Preço total: $1,113.03
Preço unitário: $1,113.03
Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Related products

Best sellers

Mais informação



Dados técnicos

Dimensions
Dimensional drawingosixvgakre.jpg
Width45 mm
Height130 mm
Depth119 mm

Notes
GeneralSupport by phone or on-site (fee is charged)
Note on application
Note on applicationOnly for industrial use
Utilization restriction
EMC noteEMC: class A product, see manufacturer's declaration in the download area

Material specifications
Housing materialPolycarbonate fiber reinforced

Mounting
Mounting typeDIN rail mounting

Interfaces
Ethernet (RJ45)
Connection methodRJ45
Note on the connection methodAuto negotiation and autocrossing
Transmission speed10/100/1000 Mbps
Transmission physicsCopper
Transmission length100 m (per segment)
Signal LEDsData receive, link status
No. of channels8 (RJ45 ports)

Output data
Digital:
Output nameAlarm output

Product properties
Product typeSwitch
Product familyManaged Switch 2000
TypeBook type
MTTF381.77 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
165.29 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
20.35 Years (SN 29500 standard, temperature 70°C, operating cycle 100%)
Special propertiesExtended temperature range
Development process certified in accordance with IEC 62443-4-1
Compatible with IEC 62443-4-2
Signal delay≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the frame size)
Data management status
Article revision07
Insulation characteristics
Protection classIII (VDE 0106)
Degree of pollution2
Switch functions
Diagnostic functionsRMON History
LLDP (Link Layer Discovery Protocol)
SNMP-Traps
N:1-Portmirroring
ACD (Address Conflict Detection)
SysLog
CRC-Surveillance
Basic functionsStore-and-forward switch, complies with IEEE 802.3
Signal contact control voltagetyp. 24 V DC
PROFINET conformance classConformance-Class B
PROFINET device functionPROFINET device
Fast Startup
Filter functionsQuality of Service (8 priority classes)
Class of Service
DiffServ/DSCP
Port-Priorisierung
VLAN (up to 32 VLANs)
IGMP Snooping/Querier (v1/v2)
Auto-Query-Port
Extended Multicast Filtering
IP parameterizationDHCP client
DHCP Option 82 (Relay Agent)
DHCP server (pool-based, port-based)
BootP
DCP (Discovery and Configuration Protocol)
MAC address table8k
ManagementWeb-based management (HTTP/HTTPS)
Role-based user management (LDAP, RADIUS)
SNMPv1/v2/v3
Command Line Interface (Telnet, SSH)
RedundancyMRP (Media Redundancy Protocol)
RSTP (Rapid Spanning Tree Protocol)
FRD (Fast Ring Detection)
Large Tree Support
LACP (Link Aggregation Control Protocol)
PROFINET S2 system redundancy
Status and diagnostic indicatorsLEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)
Additional functionsJumbo frames (max. 9,600 bytes)
Transmission of MMS and GOOSE (IEC 61850-8-1)
Transmission of Modbus/TCP
Time synchronizationSNTP (Simple Network Time Protocol)
Security functions
Port securityMAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass
Basic functionsStore-and-forward switch, complies with IEEE 802.3

Electrical properties
Current consumption280 mA
Local diagnosticsUS1/2 Supply voltage US1, US2 Green LED
FAIL Div. LED red
LINK Link status Green LED
Maximum power dissipation for nominal condition7.8 W (US= Min, Tamb= Max, DOI= Max)
Test section24 V supply / functional ground 500 V DC 1 min.
Ethernet interface/all other potentials 2.25 kV DC 1 min.
Transmission mediumCopper
Supply
Supply voltage (DC)24 V DC (redundant)
Supply voltage range12 V DC ... 57 V DC
Power supply connectionvia COMBICON, max. conductor cross section 1.5 mm²
Residual ripple3.6 VPP(within the permitted voltage range)
Max. current consumption1.4 A (US= Min, Tamb= Max, DOI= Max)
Typical current consumption280 mA (at US= 24 V DC and 25 °C ambient temperature)
Current consumption280 mA
Function
Signal contact control voltagetyp. 24 V DC

Connection data
Connection methodPush-in spring connection
Note on the connection methodUse only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C).
Conductor cross section, rigid0.25 mm² ... 1.5 mm²
Conductor cross section, flexible0.25 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length9 mm

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Shock (operation)30g (EN 60068-2-27)
Vibration (operation)in acc. with IEC 60068-2-6: 5g, 150 Hz
Air pressure (operation)80 kPa ... 110 kPa up to 2000 m above mean sea level (Without derating)
Air pressure (storage/transport)79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)

Standards and regulations
Free from substances that could impair the application of coatingYes

Approvals
Shipbuilding approvalTested in accordance with IEC 60945 and IACS E10
ATEX
Identification II 3 G Ex ec IIC T4 Gc
CertificateDEMKO 16 ATEX 1709X
References to standardsEN 60079-0
EN 60079-7
IECEx
IdentificationEx ec IIC T4 Gc
CertificateIECEx ULD 16.0018 X
References to standardsIEC 60079-0
IEC 60079-7
UL, USA/Canada
IdentificationcULus
UL Ex, USA / Canada
IdentificationClass I, Division 2, Groups A, B, C, and D, T4
Class I, Zone 2, AEx ec IIC T4
Ex ec IIC T4 Gc X
CertificateE366272
NoteUL 60079-0 Ed. 6 / UL 60079-7 Ed. 5, CSA 22.2 No. 60079-0 Ed. 3 / CSA C22.2 No. 60079-7 Ed. 2
EAC Ex
Identification2Ex e IIC T4 Gc X
CertificateRU C-DE.HB49.B.00118/21
The following continue to apply for EAC Ex:
IdentificationInstall the device in a suitable, approved housing with at least IP66 protection.
The operation of devices is permitted if all optical ports are connected or sealed with the supplied filler plugs.
CCC / China-Ex
IdentificationEx ec IIC T4 Gc
Certificate2022122310115629
Corrosive gas test
IdentificationISA S71.04.2013 G3 Harsh Group A
UKCA Ex (UKEX)
Identification II 3 G Ex ec IIC T4 Gc
CertificatePxCIMA22UKEX2702910X
DNV GL data
TemperatureB
HumidityB
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conformance with EMC directivesEN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
EN 61000-6-2 EN 61000-6-4 (interference) Class A
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
Noise immunityEN 61000-6-2
Noise emissionEN 61000-6-4

System properties
Functionality
Basic functionsStore-and-forward switch, complies with IEEE 802.3

Signaling
Status displayLEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)

ETIM for 2702652 Dados e telecomunicações (EC000734)
Característica Valor
Ethernet (EF003535) Sim
Número de outras portas (EF007643) 8
Método de montagem (EF000003) Outro
Gerível (EF004912) Sim
Grau de proteção (IP) (EF005474) IP20
Altura (EF000040) 130.592254 mm
Largura (EF000008) 45 mm
Profundidade (EF000049) 125.1 mm

Datasheet - PDF

Título: Tamanho: Tipo:
PDF CATALOG PHOENIX AUTOMATION EN.pdf 35 Mbytes

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.