Produto adicionado com sucesso ao seu carrinho de compras
HDFKV 95-F
0709673
PHOENIX_CONTACT
10
Borne de passagem
Régua de terminais, tipo de conexão: Conexão roscada com cápsula de tração, Conexão roscada com cápsula de tração, número de polos: 1, corrente de carga: 232 A, seção transversal: 25 mm² - 95 mm², direção de conexão do condutor em relação à direção do plugue: -90 °, largura: 25 mm
Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 232 A, cross section: 25 mm2 - 95 mm2, connection direction of the conductor to plug-in direction: -90 °, width: 25 mm, color: gray
Blocos de terminais > Terminal de alimentação
Conectores PCB
Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT
Obrigado pelo seu interesse nos nossos artigos, esperamos que o prazo indicado seja conveniente para si.
Durante a preparação do pedido pode seleccionar o tipo de envío que melhor se adapte ás suas necessidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
| Product type | Panel feed-through terminal block |
| Product family | HDFKV 95 |
| Number of positions | 1 |
| Pitch | 25 mm |
| Number of connections | 2 |
| Number of rows | 1 |
| Number of potentials | 1 |
| Data management status | |
| Article revision | 06 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Nominal current IN | 232 A |
| Nominal voltage UN | 1000 V (With metal panels of 1 mm ... 2.5 mm) |
| Rated voltage (III/3) | 1000 V |
| Rated surge voltage (III/3) | 8 kV |
| Connection technology | |
| Connector system | HDFK 95 |
| Nominal cross section | 95 mm² |
| Conductor connection exterior | |
| Connection method | Screw connection with tension sleeve |
| Connection direction of the conductor to plug-in direction | -90 ° |
| Conductor cross section rigid | 25 mm² ... 95 mm² |
| Conductor cross section flexible | 35 mm² ... 95 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 35 mm² ... 95 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 35 mm² ... 95 mm² |
| 2 conductors with same cross section, solid | 16 mm² ... 35 mm² |
| 2 conductors with same cross section, flexible | 16 mm² ... 35 mm² |
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 16 mm² ... 35 mm² |
| Internal cylindrical gage | B12 |
| Stripping length | 27 mm |
| Tightening torque | 15 Nm ... 20 Nm |
| Conductor connection interior | |
| Connection method | Screw connection with tension sleeve |
| Connection direction of the conductor to plug-in direction | -90 ° |
| Conductor cross section rigid | 25 mm² ... 95 mm² |
| Conductor cross section flexible | 35 mm² ... 95 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 35 mm² ... 95 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 35 mm² ... 95 mm² |
| 2 conductors with same cross section, solid | 16 mm² ... 35 mm² |
| 2 conductors with same cross section, flexible | 16 mm² ... 35 mm² |
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 16 mm² ... 35 mm² |
| Internal cylindrical gage | B12 |
| Stripping length | 27 mm |
| Tightening torque | 15 Nm ... 20 Nm |
| Material data - contact | |
| Note | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
| Contact material | Cu alloy |
| Surface characteristics | tin-plated |
| Material data - housing | |
| Color (Housing) | gray (7042) |
| Insulating material | PA |
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Flammability rating according to UL 94 | V0 |
| Glow wire flammability index GWFI according to EN 60695-2-12 | 850 |
| Glow wire ignition temperature GWIT according to EN 60695-2-13 | 775 |
| Temperature for the ball pressure test according to EN 60695-10-2 | 125 °C |
| Safety note | |
| Safety note | • Only electrically qualified personnel may install and operate the product. To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering. |
| • Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data. | |
| • The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection. | |
| Dimensional drawing | ![]() |
| Pitch | 25 mm |
| Width [w] | 25 mm |
| Height [h] | 96 mm |
| External dimensions | |
| Width [w] | 25 mm |
| Height [h3] | 96 mm |
| Length [l1] | 78.7 mm |
| Internal dimensions | |
| Width [w] | 25 mm |
| Height [h4] | 74 mm |
| Length [l2] | 45 mm |
| Air clearances and creepage distances 1. Insulation coordination | |
| Application | Metal wall 1.0 mm ... 2.5 mm |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Rated insulation voltage (III/3) | 1000 V |
| Rated surge voltage (III/3) | 8 kV |
| minimum clearance value - non-homogenous field (III/3) | 8 mm |
| minimum creepage distance (III/3) | 12.5 mm |
| Air clearances and creepage distances 2. Insulation coordination | |
| Application | Metal panel > 2.5 mm ... 5.0 mm |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Rated insulation voltage (III/3) | 800 V |
| Rated surge voltage (III/3) | 8 kV |
| minimum clearance value - non-homogenous field (III/3) | 8 mm |
| minimum creepage distance (III/3) | 10 mm |
| Air clearances and creepage distances 3. Insulation coordination | |
| Application | Metal panel > 5.0 mm ... 6.0 mm |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Rated insulation voltage (III/3) | 690 V |
| Rated surge voltage (III/3) | 8 kV |
| minimum clearance value - non-homogenous field (III/3) | 8 mm |
| minimum creepage distance (III/3) | 8 mm |
| Air clearances and creepage distances 4. Insulation coordination | |
| Application | Plastic panel 1.0 ... 6.0 mm |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Rated insulation voltage (III/3) | 1000 V |
| Rated surge voltage (III/3) | 8 kV |
| minimum clearance value - non-homogenous field (III/3) | 8 mm |
| minimum creepage distance (III/3) | 12.5 mm |
| Type of packaging | packed in cardboard |
| Título: | Tamanho: | Tipo: |
|---|---|---|
| PDF CATALOG PHOENIX PCB CONNECTORS EN.pdf | 27 Mbytes |
|
| PHOENIX CONTACT-0709673-HDFKV 95-F | 128 Kbytes |
![]() |
Não há comentários do produto ainda.
| Avaliação: |
|
| Nome: | |
| Email: | |
| Título: | |
| Opinión: | |
| Você recomendaria esse produto para comprar? | |
|
|
|
| Adicionar avaliação | |
Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.