Produto adicionado com sucesso ao seu carrinho de compras
ZX-XGC5A
238021
ZXXGC5A
OMRON
1
Disponível Envio hoje
Cabo de extensão 5m para sensores série ZX-G
Sensores Avançados > Acessórios Sensores Avançados
* Produto novo em sua embalagem original com todas as garantias e certificações de OMRON
Obrigado pelo seu interesse nos nossos artigos, esperamos que o prazo indicado seja conveniente para si.
Durante a preparação do pedido pode seleccionar o tipo de envío que melhor se adapte ás suas necessidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
Up to two extension cables can be connected. However, be sure to limit the total extension cable length between the receiver and the controller to 30 meters (including the receiver cable). |
---|
Visible semiconductor laser diode (wavelength 650 nm, CLASS 1 of EN60825-1/IEC60825-1, CLASS of FDA(21CFR 1040.10 and 1040.11) | ||||
0.5 mm dia.1 | 0.5 mm dia.1 | |||
±0.1% F.S.2 | ||||
10 µm (number of process values to average: 16)3 | ||||
±0.01% F.S/C4 | ||||
ON: Short-circuited with 0 V or 1.5 V max. | ON: Short-circuited with power supply voltage or | |||
NPN open-collector output | PNP open-collector output | |||
1,000 lx (incandescent light)5 | ||||
Operating: 0 to 40°C, storage: -15 to 50°C (with no icing or condensation) | ||||
10 to 150 Hz single-amplitude: 0.75 mm for 80 min each in X, Y and Z directions | ||||
Measurement cycle6 | 1.5 ms (standard mode (NORM)) | ||
Analog output8 | For current output: 4 to 20 mA/F.S., max. load resistance 300Ω | ||
Timing input, bank switching input, zero reset input, reset input | ON: short-circuited with 0 V or 1.5 V max. | ON: short-circuited with power supply voltage or | |
NPN open-collector output | PNP open-collector output | ||
Judgment output indicator: HIGH (orange), PASS (green), LOW (orange) | |||
Interrupted beam width measurement, incident beam width measurement, outer diameter measurement, center position measurement, IC lead pitch, | |||
Measured value, resolution, threshold, voltage output value, current output value (number of display digits can be changed) | |||
Sample hold, peak hold, bottom hold, peak-to-peak hold, average hold, delay hold | |||
Optical axis adjust mode/light intensityt writing mode, variable binary level, variable edge filter, analog output scaling | |||
2 possible on up to two controllers (calculation Unit ZX-CAL2 is required for connecting controllers to each other.) A-B, A+B, width | |||
Measurement cycle setting, threshold setting, hysteresis setting, initialization, key lock | |||
Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation) | |||
10 to 150 Hz single-amplitude: 0.35 mm for 80 min each in X, Y and Z directions | |||
Case: PBT (polybutylene terephthalate), cover: Polycarbonate | |||
1.Distance between emitter and receiver: 500 mm, measurement object at 250 mm from receiver. Glass ends of chamfer 0.1 mm or more can be detected in glass edge measurement mode. (at binary level 70%)
2.Linearity is given to be a typical error with respect to an ideal straight line when the distance between the emitter and receiver is 100 mm and light is blocked at a distance of 50 mm from the receiver. (On the ZX-GT2840_, the measurement object is measured at a distance of 20 mm from the receiver.)
3.The amount of fluctuation (±3σ) in the analog output when the distance between the emitter and receiver is 100 mm and a ZX-GTC_ is connected
4.Change in the light cutoff value on one side when the distance between the emitter and receiver is 100 mm and the light is half-cutoff at a distance of 50 mm from the receiver (On the
ZX-GT2840_, the measurement object is measured at a distance of 20 mm from the receiver.)
6.The first response time is “measurement cycle x (number of samples to average setting + 1) + 1 ms” max. For the second response time onwards, the specified measurement cycle time is output.
7.The response time in the high-speed mode (FAST) for the IC lead pitch and IC lead width judgment modes is 1 ms.
11.Normally, wire the sync output wire directly to the emitter's sync input wire and run the controller in the standard mode. On an NPN type controller, use an NPN type emitter, and on a PNP type controller, use a PNP type emitter. Wiring of the sync wires is not required when the controller is run in the high-speed mode.
(Note, however, that the controller becomes more susceptible to the influence of ambient light in this case.)
Título: | Tamanho: | Tipo: |
---|---|---|
ZX-XGC5A ZXXGC5A 238021 measurement_sensors_brochure_en.pdf | 1 Mbytes | |
ZX-XGC5A ZXXGC5A 238021 q154_zx_gt_brochure_en.pdf | 3 Mbytes |
Não há comentários do produto ainda.
Avaliação: | |
Nome: | |
Email: | |
Título: | |
Opinión: | |
Você recomendaria esse produto para comprar? | |
Adicionar avaliação |
Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.