EATON - MOELLER RAMO5-D200A32-512RS1 199073 Y7-199073 - Imagem 1

As imagens são só a título ilustrativo. Por favor, consulte a ficha técnica.

RAMO5-D200A32-512RS1 199073 Y7-199073 EATON ELECTRIC Partida DOL 6.6 A 400 V 50 Hz 0.09 3 kW S-7.4.A.E Para ..

Referência: RAMO5-D200A32-512RS1

Código: 199073

Número de catálogo: Y7-199073

Fabricante: EATON - MOELLER

Descrição:

Partida DOL 6.6 A 400 V 50 Hz 0.09 - 3 kW S-7.4.A.E Para 62
Eaton Moeller® series Rapid Link - DOL starter, 6.6 A, Sensor input 2, AS-Interface®, S-7.A.E. for 62 modules, HAN Q5, with manual override switch
DOL Starter, 6.6 A, Sensor Input 2, AS-Interface®, S-7.A.E. para 62 módulos, HAN Q5, com interruptor de substituição manual

Categorias:

  • Aparelhos elétricos de baixa tensão > Combinação de acionador de partida de motor/motor de arranque
  • EATON - MOELLER > Acionadores Rapid Link

Produto novo em sua embalagem original com todas as garantias e certificações de EATON - MOELLER

  • Mais informação
  • ETIM
  • Avaliações
Garantia, reparação e devolução.

Preço unitário: 915,95 €

Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

Calcule o preço por quantidade

QuantidadePreço

Prazo padrão: 3 semanas.

  • Estes prazos são estimativos e podem variar uma vez tratado o pedido do artigo.

JÁ VISTOS

MAIS INFORMAÇÃO

General specifications

Product Name
Eaton Moeller® series Rapid Link DOL starter
Catalog Number
199073
EAN
4015081971312
Product Length/Depth
120 mm
Product Height
270 mm
Product Width
220 mm
Product Weight
1.8 kg
Certifications
CE
CCC
IEC/EN 60947-4-2
UL 60947-4-2
RoHS
UL approval
Catalog Notes
Assigned motor rating: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm at 50 Hz or 1800 min at 60 Hz
Model Code
RAMO5-D200A32-512RS1

Especificações do produto

Type
DOL starter
Features
Diagnostics and reset on device and via AS-Interface
Parameterization: Fieldbus
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
Parameterization: Keypad
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Fitted with:
Manual override switch
Thermistor monitoring PTC
Electronic motor protection
Key switch position AUTO
Thermo-click
Key switch position OFF/RESET
Key switch position HAND
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Short-circuit release
Class
CLASS 10 A
Lifespan, electrical
10,000,000 Operations (at AC-3)
Climatic proofing
< 95 %, no condensation
In accordance with IEC/EN 50178
Rated impulse withstand voltage (Uimp)
4000 V
Model
Direct starter
Altitude
Max. 2000 m
Max. 1000 m
Above 1000 m with 1 % performance reduction per 100 m
Lifespan, mechanical
10,000,000 Operations (at AC-3)
Mains switch-on frequency
Maximum of one time every 60 seconds
Electrical connection type of main circuit
Plug-in connection
Mains voltage tolerance
380 - 480 V (-15 %/+10 %, at 50/60 Hz)
Voltage type
DC
Mounting position
Vertical
Rated conditional short-circuit current (Iq)
10 kA
Overvoltage category
III
Connection
Connections pluggable in power section
Off-delay
20 - 35 ms
Functions
External reset possible
Temperature compensated overload protection
On-delay
20 - 35 ms
System configuration type
Phase-earthed AC supply systems are not permitted.
AC voltage
Center-point earthed star network (TN-S network)
Electromagnetic compatibility
Class A
Current limitation
0.3 - 6.6 A, motor, main circuit
Adjustable, motor, main circuit
Output frequency
50/60 Hz
Overload cycle
AC-53a
Overload release current setting - min
0.3 A
Rated conditional short-circuit current (Iq), type 2, 230 V
0 A
Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V
0 A
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000 A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0 A
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at DC - max
0 V
Rated control supply voltage (Us) at DC - min
0 V
Rated frequency - max
63 Hz
Rated frequency - min
47 Hz
Rated operational current (Ie) at 150% overload
6.6 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
6.6 A
Shock resistance
15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaft
Interfaces
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Specification: S-7.A.E. (AS-Interface®)
Number of slave addresses: 62 (AS-Interface®)
Protocol
AS-Interface profile cable: S-7.4 for 62 modules
ASI
Rated control voltage (Uc)
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Supply frequency
50/60 Hz, fLN, Main circuit
Rated operational current (Ie)
6.6 A
Rated operational power at 380/400 V, 50 Hz - max
3 kW
Rated operational power at 380/400 V, 50 Hz - min
0.09 kW
Rated operational voltage
400 V AC, 3-phase
480 V AC, 3-phase
Short-circuit protection (external output circuits)
Type 1 coordination via the power bus' feeder unit, Main circuit
Vibration
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Ambient operating temperature - max
55 °C
Ambient operating temperature - min
-10 °C
Ambient storage temperature - max
70 °C
Ambient storage temperature - min
-40 °C
Assigned motor power at 460/480 V, 60 Hz, 3-phase
3 HP
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Number of command positions
1
Number of pilot lights
0
Overload release current setting - max
6.6 A
Rated operational power at AC-3, 220/230 V, 50 Hz
0 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
3 kW
Rated power at 460 V, 60 Hz, 3-phase
2.238 kW
Rated power at 575 V, 60 Hz, 3-phase
0 kW
Product category
Motor starter
Cable length
10 m, Radio interference level, maximum motor cable length
Coordination class (IEC 60947-4-3)
Class 1
Degree of protection
IP65
NEMA 12
Electrical connection type for auxiliary- and control-current circuit
Plug-in connection
Input current
6.6 A (at 150 % Overload)
Power consumption
8 W

ETIM for 199073 Componentes industriais para Baixa Tensão (EC001037)

Nome da característicaTipo de arranque de motor (EF009598)
Valor da característicaArranque direto
Nome da característicaCom disparo de curto-circuito (EF006691)
Valor da característicaSim
Nome da característicaTensão de alimentação de corrente nominal de 50 Hz AC (EF003978)
Valor da característica0 V
Nome da característicaTensão de alimentação de corrente nominal de 60 Hz CA (EF003979)
Valor da característica0 V
Nome da característicaTensão de alimentação de corrente nominal DC (EF003980)
Valor da característica0 V
Nome da característicaTipo de tensão para atuação (EF008242)
Valor da característicaDC
Nome da característicaPotência de operação nominal em AC-3, 230 V, trifásica (EF009599)
Valor da característica0 kW
Nome da característicaPotência de operação nominal em AC-3, 400 V (EF001364)
Valor da característica3 kW
Nome da característicaPotência nominal, 460 V, 60 Hz, trifásica (EF009600)
Valor da característica2.238 kW
Nome da característicaPotência nominal, 575 V, 60 Hz, trifásica (EF009601)
Valor da característica0 kW
Nome da característicaCorrente nominal de operação Ie (EF001443)
Valor da característica6.6 A
Nome da característicaCorrente nominal de operação em AC-3, 400 V (EF009602)
Valor da característica6.6 A
Nome da característicaConfiguração de corrente da proteção contra sobrecargas (EF002336)
Valor da característica0.3 A
Nome da característicaCorrente nominal de curto-circuito condicional, tipo 1, 480 Y/277 V (EF009607)
Valor da característica10000 A
Nome da característicaCorrente nominal de curto-circuito condicional, tipo 1, 600 Y/347 V (EF009608)
Valor da característica0 A
Nome da característicaCorrente nominal de curto-circuito condicional, tipo 2, 230 V (EF009606)
Valor da característica0 A
Nome da característicaCorrente nominal de curto-circuito condicional, tipo 2, 400 V (EF009605)
Valor da característica0 A
Nome da característicaConsumo (potência em VA) (EF000346)
Valor da característica8 W
Nome da característicaNúmero de contatos auxiliares como contato normalmente aberto (EF001376)
Valor da característica0
Nome da característicaNúmero de contatos auxiliares como contato normalmente fechado (EF001377)
Valor da característica0
Nome da característicaTemperatura ambiente, limite superior de operação (EF009603)
Valor da característica55 °C
Nome da característicaProteção contra sobrecarga de temperatura compensada (EF009604)
Valor da característicaSim
Nome da característicaClasse de engate/gatilho (EF006668)
Valor da característicaCLASSE 10 A
Nome da característicaTipo de conexão elétrica do circuito principal (EF006819)
Valor da característicaConexão por encaixe
Nome da característicaTipo de conexão elétrica para circuito de corrente auxiliar e de controlo (EF006979)
Valor da característicaConexão por encaixe
Nome da característicaPossível montagem em calha (EF003972)
Valor da característicaNão
Nome da característicaCom transformador (EF000278)
Valor da característicaNão
Nome da característicaNúmero de posições de comando (EF001372)
Valor da característica1
Nome da característicaAdequado para paragem de emergência (EF001433)
Valor da característicaNão
Nome da característicaClasse de coordenação de acordo com IEC 60947-4-3 (EF012390)
Valor da característicaClasse 1
Nome da característicaNúmero de luzes indicadoras (EF001965)
Valor da característica0
Nome da característicaPossível reinicialização externa (EF003426)
Valor da característicaSim
Nome da característicaCom fusível (EF006693)
Valor da característicaNão
Nome da característicaGrau de proteção (IP) (EF005474)
Valor da característicaIP65
Nome da característicaGrau de proteção (NEMA) (EF011959)
Valor da característica12
Nome da característicaSuporta o protocolo TCP/IP (EF003050)
Valor da característicaNão
Nome da característicaSuporta o protocolo PROFIBUS (EF003052)
Valor da característicaNão
Nome da característicaSuporta o protocolo CAN (EF003053)
Valor da característicaNão
Nome da característicaSuporta o protocolo INTERBUS (EF003054)
Valor da característicaNão
Nome da característicaSuporta o protocolo ASI (EF003051)
Valor da característicaSim
Nome da característicaSuporta o protocolo MODBUS (EF003057)
Valor da característicaNão
Nome da característicaSuporta o protocolo Data-Highway (EF003058)
Valor da característicaNão
Nome da característicaSuporta o protocolo DeviceNet (EF003059)
Valor da característicaNão
Nome da característicaSuporta o protocolo SUCONET (EF003060)
Valor da característicaNão
Nome da característicaSuporta protocolo LON (EF003017)
Valor da característicaNão
Nome da característicaSuporta o protocolo PROFINET IO (EF007525)
Valor da característicaNão
Nome da característicaSuporta o protocolo PROFINET CBA (EF007524)
Valor da característicaNão
Nome da característicaSuporta o protocolo SERCOS (EF006657)
Valor da característicaNão
Nome da característicaSuporta o protocolo o Foundation Fieldbus (EF007522)
Valor da característicaNão
Nome da característicaSuporta o protocolo Ethernet/IP (EF007521)
Valor da característicaNão
Nome da característicaProtocolo de suporte à segurança da interface AS no trabalho (EF007519)
Valor da característicaNão
Nome da característicaSuporta o protocolo DeviceNet Safety (EF007520)
Valor da característicaNão
Nome da característicaSuporta o protocolo INTERBUS-Safety (EF006662)
Valor da característicaNão
Nome da característicaSuporta o protocolo PROFIsafe (EF007526)
Valor da característicaNão
Nome da característicaSuporta o protocolo SafetyBUS p (EF007527)
Valor da característicaNão
Nome da característicaSuporta o protocolo outros sistemas de barramento (EF003062)
Valor da característicaNão
Nome da característicaLargura (EF000008)
Valor da característica220 mm
Nome da característicaAltura (EF000040)
Valor da característica270 mm
Nome da característicaProfundidade (EF000049)
Valor da característica120 mm

DATASHEET - PDF

Últimas opiniões dos nossos clientes

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.