ANUNCIAR
M22-K01 216378 Y7-216378 EATON ELECTRIC M22-K01Q auxiliar contato 1NC Ver maior
As imagens são só a título ilustrativo. Por favor, consulte a ficha técnica.

M22-K01 216378 Y7-216378 EATON ELECTRIC M22-K01Q auxiliar contato 1NC

M22-K01

216378

Y7-216378

EATON-MOELLER

M22-K01Q auxiliar contato 1NC

Elemento de contato 1 NC Conexão de parafuso de montagem frontal

Eaton Moeller® series M22 Contact element, Screw terminals, Front fixing, 1 NC, 24 V 3 A, 220 V 230 V 240 V 6 A M22-K01

Elemento de contacto, Norma/Aprovação: UL/CSA, IEC, Tamanho de construção: NZM1/2/3/4, Técnica de ligação: Terminais de parafuso, Fixação: Fixação frontal, Contactos N/C = Normalmente fechado: 1 NF, Contactos Notas: = Função de segurança, por abertura positiva de acordo com IEC/EN 60947-5-1, Curso do atuador e força de acionamento de acordo com DIN EN 60947-5-1, K.5.4.1: 4,8 mm, Curso máximo: 5,7 mm, Força mínima para abertura positiva: N 15, Grau de proteção: IP20, Conexão ao SmartWire-DT: não, Tipo de conexão: Contato único, Descrição do indicador de disparo do contato auxiliar HIA: Indicação geral de disparo '+', ao disparar por liberação de bypass, liberação de sobrecarga, liberação de curto-circuito ou por liberação de corrente residual devido à corrente residual., Pode ser usado

Mais detalhes


Aparelhos elétricos de baixa tensão > Bloco de contatos auxiliares

Auxiliares de controle e sinalização

Produto novo em sua embalagem original com todas as garantias e certificações de EATON-MOELLER

Preço total: $5.38
Preço unitário: $5.38
Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Related products

geralmente comprados juntos

Best sellers

Mais informação



General specifications

Product Name
Eaton Moeller® series M22 Accessory Contact element
Catalog Number
216378
Packing Unit
Pack
EAN
4015081846122
Quantity
20
Gross Weight
0.218 kg
Length
91 mm
Width
75 mm
Height
60 mm
Volume
409.5 cm³
ERP Name
SAP-UNITY
Product Length/Depth
38 mm
Product Height
10 mm
Product Width
32 mm
Product Weight
0.01 kg
Compliances
CE Marked
Certifications
CSA Std. C22.2 No. 14-05
IEC 60947-5
CSA Std. C22.2 No. 94-91
UL 508
EN 60947-5
VDE
CSA-C22.2 No. 94-91
IEC
IEC 60947-5-1
CSA
CSA Class No.: 3211-03
CSA-C22.2 No. 14-05
CSA File No.: 012528
UL
UL Category Control No.: NKCR
UL File No.: E29184
CE
IEC/EN 60947-5
UL/CSA
Model Code
M22-K01

Especificações do produto

Type
Auxiliary contact
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Electric connection type
Screw connection
Operating frequency
3600 Operations/h
Pollution degree
3
Used with
Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.
Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker.
Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Actuating force - max
5 N
Actuator travel and actuation force (DIN EN 60947-5-1)
4.8 mm
Ambient operating temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Conventional thermal current ith of auxiliary contacts (1-pole, open)
4 A
Equipment heat dissipation, current-dependent Pvid
0 W
Force for positive opening - min
15 N
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.11 W
Knob travel
5.7 mm
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
1
Number of contacts (normally open contacts)
0
Number of switches (fault signal)
0
Connection to SmartWire-DT
No
Rated impulse withstand voltage (Uimp)
6000 V AC
Contact configuration
1 NC
Rated conditional short-circuit current (Iq)
1 kA
Connection type
Front fixing
Single contact
Mounting method
Front fastening
Overvoltage category
III
Control circuit reliability
1 failure per 5,000,000 switching operations (statistically determined, at 5 V DC/1 mA)
1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA)
Degree of protection
IP20
Model
Top mounting and integrable
Lamp holder
None
Terminal capacity (solid/flexible with ferrule)
2 x (0,5 - 0,75) mm²
1 x (0,75 - 2,5) mm²
Rated operational current (Ie)
5 A – 600 V AC
1 A - 250 V DC
Lifespan, electrical
1,200,000 Operations (at 12 V, DC-13, 2.8 A)
1,600,000 Operations (at 230 V, 0.5 A)
700,000 Operations (at 230 V, AC-15, 3 A)
1,000,000 Operations (at 230 V, AC-15, 1 A)
Terminal capacity (stranded)
0.5 - 2.5 mm²
Lifespan, mechanical
5,000,000 Operations
Short-circuit protection
PKZM0-10/FAZ-B6/1, Contacts, Max. short-circuit protective device, Fuseless
Static heat dissipation, non-current-dependent Pvs
0 W
Product category
Accessories
Rated operational current (Ie) at DC-13, 500 V
0.1 A
Short-circuit protection rating
Max. 10 A gG/gL, Fuse, Contacts
Max. 10 A gG/gL, Fuse, Auxiliary contacts
Operating torque
0.8 Nm
Rated insulation voltage (Ui)
500 V
Rated operational current (Ie) at AC-15, 115 V
6 A
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
6 A
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V
4 A
Rated operational current (Ie) at AC-15, 500 V
2 A
Rated operational current (Ie) at DC-13, 110 V
0.6 A
Rated operational current (Ie) at DC-13, 220 V, 230 V
0.3 A
Rated operational current (Ie) at DC-13, 24 V
3 A
Rated operational current (Ie) at DC-13, 42 V
1.7 A
Rated operational current (Ie) at DC-13, 60 V
1.2 A
Rated operational current for specified heat dissipation (In)
6 A
Rated operational voltage (Ue) at AC - max
500 V
Rated operational voltage (Ue) at DC - max
220 V
Terminal capacity (flexible with ferrule)
0.5 - 1.5 mm²
Terminal capacity (solid)
0.75 - 2.5 mm²
Shock resistance
30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms
Switching time
NZM1, PN1, N(S)1: approx. 20 ms (with manual operation)
NZM2, PN2, N(S)2: approx. 20 ms (with manual operation)
NZM3, PN3, N(S)3: approx. 20 ms (with manual operation)
NZM4, N(S)4: approx. 90 ms, the HIV does not feature early break (with manual operation)

ETIM for 216378 Componentes industriais para Baixa Tensão (EC000041)
Característica Valor
Número de contatos como inversores (EF008257) 0
Número de contatos como contato normalmente aberto (EF008256) 0
Número de contatos como contato normalmente fechado (EF008255) 1
Número de comutadores de sinal de erro (EF007613) 0
Corrente nominal de operação Ie em AC-15, 230 V (EF001385) 6 A
Acabamento da conexão elétrica (EF003961) Ligação com parafuso
Modelo (EF000010) Elevável e integrável
Método de montagem (EF000003) Fixação frontal
Suporte da lâmpada (EF000048) Nenhum

Datasheet - PDF

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.