ANUNCIAR
M22-LH-B 216782 Y7-216782 EATON ELECTRIC M22-LH-BQ Salient Lamp, Azul Ver maior
As imagens são só a título ilustrativo. Por favor, consulte a ficha técnica.

M22-LH-B 216782 Y7-216782 EATON ELECTRIC M22-LH-BQ Salient Lamp, Azul

M22-LH-B

216782

Y7-216782

EATON-MOELLER

10

M22-LH-BQ Salient Lamp, Azul

Luz indicadora 22 mm Azul Cônico

Eaton Moeller® series M22 Indicator light, RMQ-Titan, Extended, conical, Blue

Indicador luminoso, Família de produtos: RMQ-Titan, Unidade única, Design: Estendido, cônico, Cor da lente: Azul, Grau de proteção: IP66, IP67, IP69K, Conexão SmartWire-DT: sim, com conexões SWD-RMQ, Dimensões frontais: 29,7, Normas: IEC/EN 60947, VDE 0660

Mais detalhes


Aparelhos elétricos de baixa tensão > Elemento frontal para luz indicadora

Auxiliares de controle e sinalização

Produto novo em sua embalagem original com todas as garantias e certificações de EATON-MOELLER

Preço total: $75.50
Preço unitário: $7.55
Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Related products

geralmente comprados juntos

Best sellers

Mais informação



General specifications

Product Name
Eaton Moeller® series M22 Indicator light
Catalog Number
216782
EAN
4015082167820
Product Length/Depth
30 mm
Product Height
38 mm
Product Width
30 mm
Product Weight
0.007 kg
Certifications
CSA Class No.: 3211-03
CSA-C22.2 No. 94-91
CE
CSA
CSA-C22.2 No. 14-05
IEC/EN 60947-5
UL 508
VDE 0660
UL
CSA File No.: 012528
IEC/EN 60947
UL Category Control No.: NKCR
UL File No.: E29184
Model Code
M22-LH-B

Especificações do produto

Type
Indicator lights
10.10 Temperature rise
Not applicable.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Fitted with:
Front ring
Pollution degree
3
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Connection to SmartWire-DT
Yes
With SWD-RMQ connections
Rated impulse withstand voltage (Uimp)
4000 V AC
Bezel color
Chrome
Shock resistance
30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms
Mechanical, According to IEC/EN 60068-2-27
Bezel material
Other
Terminal capacity
0.5 - 1.5 mm², solid
0.5 - 1.5 mm², stranded
Lens color
Blue
Design
Extended, conical
Mounting position
As required
Overvoltage category
III
Degree of protection
NEMA 4X, 13
Ambient operating temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Equipment heat dissipation, current-dependent Pvid
0 W
Force for positive opening - min
0 N
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Opening diameter
22.5 mm
Opening height
22.5 mm
Rated insulation voltage (Ui)
250 V
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
Suitable for number of built-in signal lights
1
Width opening
0 mm
Product category
RMQ-Titan
Size
Front diameter: 29.7 mm
Degree of protection (front side)
IP67/IP69K
Lens type
Round
High

ETIM for 216782 Componentes industriais para Baixa Tensão (EC000223)
Característica Valor
Adequado para o número de luzes de sinalização incorporadas (EF006669) 1
Cor da lente (EF000207) Azul
Forma de lente (EF006253) Redondo
Diâmetro do furo (intervalo) (EF000079) 22.5 mm
Largura da abertura (EF004565) 0 mm
Altura da abertura (EF004778) 22.5 mm
Com anel frontal (EF006014) Sim
Material do anel frontal (EF005972) Outro
Cor do anel frontal (EF002429) Crómio
Tipo de lente (EF008343) Alto
Grau de proteção (IP), frente (EF003118) IP67/IP69
Grau de proteção (NEMA) (EF011959) 4X, 13

Datasheet - PDF

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.