Name | Appearance | Cable length L (mm) | Applicable connectors | Order code |
---|
Cables with Loose Wires and Crimp Terminals XW2Z-RY_C | 16 I/O points |
| 1,000 | Various devices | XW2Z-RY100C |
1,500 | XW2Z-RY150C |
2,000 | XW2Z-RY200C |
3,000 | XW2Z-RY300C |
5,000 | XW2Z-RY500C |
Cables with Loose Wires XW2Z-RA_C | 16 I/O points |
| 2,000 | Various devices | XW2Z-RA200C |
5,000 | XW2Z-RA500C |
Cables with Connectors (1:1) XW2Z-R_C | 16 I/O points |
| 500 | PLC I/O Units with Fujitsu connectors (1:1) | XW2Z-R50C |
1,000 | XW2Z-R100C |
1,500 | XW2Z-R150C |
2,000 | XW2Z-R200C |
3,000 | XW2Z-R300C |
5,000 | XW2Z-R500C |
Cables with Connectors (1:2) XW2Z-RI_C-_, XW2Z-RO_C-_ | 32 input points |
| (A) 1,000 | (B) 750 | PLC I/O Units with Fujitsu connectors (1:2) | XW2Z-RI100C-75 |
(A) 1,500 | (B) 1,000 | XW2Z-RI150C-100 |
(A) 1,500 | (B) 1,250 | XW2Z-RI150C-125 |
(A) 2,000 | (B) 1,750 | XW2Z-RI200C-175 |
(A) 3,000 | (B) 2,750 | XW2Z-RI300C-275 |
(A) 5,000 | (B) 4,750 | XW2Z-RI500C-475 |
32 output points | (A) 1,000 | (B) 750 | XW2Z-RO100C-75 |
(A) 1,500 | (B) 1,000 | XW2Z-RO150C-100 |
(A) 1,500 | (B) 1,250 | XW2Z-RO150C-125 |
(A) 2,000 | (B) 1,500 | XW2Z-RO200C-150 |
(A) 2,000 | (B) 1,750 | XW2Z-RO200C-175 |
(A) 3,000 | (B) 2,750 | XW2Z-RO300C-275 |
(A) 5,000 | (B) 4,750 | XW2Z-RO500C-475 |
Cables with Connectors (1:3) XW2Z-R_C-_-_ | 48 I/O points |
| (A) 1,500 | (B) 1,250 | (C) 1,000 | PLC I/O Units with Fujitsu connectors (1:3) | XW2Z-R150C-125-100 |
(A) 2,000 | (B) 1,750 | (C) 1,500 | XW2Z-R200C-175-150 |
(A) 3,000 | (B) 2,750 | (C) 2,500 | XW2Z-R300C-275-250 |
Cables with Connectors (1:1) XW2Z-RI_C, XW2Z-RO_C | 16 input points |
| 250 | PLC I/O Units with MIL connectors (1:1) | XW2Z-RI25C |
500 | XW2Z-RI50C |
16 output points | 250 | XW2Z-RO25C |
500 | XW2Z-RO50C |
Cables with Connectors (1:2) XW2Z-RI_-_-D1, XW2Z-RO_-_-D1, XW2Z-RM_-_-D1, XW2Z-RI_-_-D2, XW2Z-RM_-_-D2 | 32 input points |
| (A) 500 | (B) 250 | PLC I/O Units with MIL connectors (NPN) (1:2) | XW2Z-RI50-25-D1 |
(A) 750 | (B) 500 | XW2Z-RI75-50-D1 |
32 output points | (A) 500 | (B) 250 | XW2Z-RO50-25-D1 |
(A) 750 | (B) 500 | XW2Z-RO75-50-D1 |
16 input points/ 16 output points | (A) 500 | (B) 250 | XW2Z-RM50-25-D1 |
(A) 750 | (B) 500 | XW2Z-RM75-50-D1 |
32 input points | (A) 500 | (B) 250 | PLC I/O Units with MIL connectors (PNP) (1:2) | XW2Z-RI50-25-D2 |
(A) 750 | (B) 500 | XW2Z-RI75-50-D2 |
16 input points/ 16 output points | (A) 500 | (B) 250 | XW2Z-RM50-25-D2 |
(A) 750 | (B) 500 | XW2Z-RM75-50-D2 |
Mitsubishi Electric PLC Connecting Cables XW2Z-RI_C-_-MN, XW2Z-RO_C-_-MN | 32 input points |
| (A) 1,000 | (B) 750 | Mitsubishi Electric PLCs with 32-point connectors (1:2) For inputs: AX42, A1SX41, A1SX42 For outputs: AY42, A1SY41, A1SY42 | XW2Z-RI100C-75-MN |
(A) 1,500 | (B) 1,250 | XW2Z-RI150C-125-MN |
(A) 2,000 | (B) 1,750 | XW2Z-RI200C-175-MN |
(A) 3,000 | (B) 2,750 | XW2Z-RI300C-275-MN |
32 output points | (A) 1,000 | (B) 750 | XW2Z-RO100C-75-MN |
(A) 1,500 | (B) 1,250 | XW2Z-RO150C-125-MN |
(A) 2,000 | (B) 1,500 | XW2Z-RO200C-150-MN |
(A) 2,000 | (B) 1,750 | XW2Z-RO200C-175-MN |
(A) 3,000 | (B) 2,750 | XW2Z-RO300C-275-MN |
Schneider Electric PLC Connecting Cables XW2Z-R_C-SCH-_ | 32 input points |
| 500 | Schneider Electric PLCs with 32-point connectors (1:2) For inputs: 140 DDI 353 00 For outputs: 140 DDO 353 00 | XW2Z-R050C-SCH-A |
1,000 | XW2Z-R100C-SCH-A |
2,000 | XW2Z-R200C-SCH-A |
3,000 | XW2Z-R300C-SCH-A |
5,000 | XW2Z-R500C-SCH-A |
32 output points | 500 | XW2Z-R050C-SCH-B |
1,000 | XW2Z-R100C-SCH-B |
2,000 | XW2Z-R200C-SCH-B |
3,000 | XW2Z-R300C-SCH-B |
5,000 | XW2Z-R500C-SCH-B |
16 input points |
| 500 | Schneider Electric PLCs with 16-point connectors (1:1) For inputs: BMX DDI 1602 For outputs: BMX DDO 1602 | XW2Z-R050C-SCH-C |
1,000 | XW2Z-R100C-SCH-C |
2,000 | XW2Z-R200C-SCH-C |
3,000 | XW2Z-R300C-SCH-C |
5,000 | XW2Z-R500C-SCH-C |
16 output points | 500 | XW2Z-R050C-SCH-D |
1,000 | XW2Z-R100C-SCH-D |
2,000 | XW2Z-R200C-SCH-D |
3,000 | XW2Z-R300C-SCH-D |
5,000 | XW2Z-R500C-SCH-D |
Siemens PLC Connecting Cables XW2Z-R_C-SIM-_ | 32 input points |
| 500 | Siemens PLCs with 32-point connectors (1:2) For inputs: 6ES7 321-1BL00-0AA0 For outputs: 6ES7 322-1BL00-0AA0 | XW2Z-R050C-SIM-A |
1,000 | XW2Z-R100C-SIM-A |
2,000 | XW2Z-R200C-SIM-A |
3,000 | XW2Z-R300C-SIM-A |
5,000 | XW2Z-R500C-SIM-A |
32 output points | 500 | XW2Z-R050C-SIM-B |
1,000 | XW2Z-R100C-SIM-B |
2,000 | XW2Z-R200C-SIM-B |
3,000 | XW2Z-R300C-SIM-B |
5,000 | XW2Z-R500C-SIM-B |
16 input points |
| 500 | Siemens PLCs with 16-point connectors (1:1) For inputs: 6ES7 321-1BH02-0AA0 | XW2Z-R050C-SIM-C |
1,000 | XW2Z-R100C-SIM-C |
2,000 | XW2Z-R200C-SIM-C |
3,000 | XW2Z-R300C-SIM-C |
5,000 | XW2Z-R500C-SIM-C |
32 input points |
| 500 | Siemens PLCs with 32-point connectors (1:2) For inputs: 6ES7 421-1BL-0AA0 For outputs: 6ES7 422-1BL-0AA0 | XW2Z-R050C-SIM-D |
1,000 | XW2Z-R100C-SIM-D |
2,000 | XW2Z-R200C-SIM-D |
3,000 | XW2Z-R300C-SIM-D |
5,000 | XW2Z-R500C-SIM-D |
32 output points | 500 | XW2Z-R050C-SIM-E |
1,000 | XW2Z-R100C-SIM-E |
2,000 | XW2Z-R200C-SIM-E |
3,000 | XW2Z-R300C-SIM-E |
5,000 | XW2Z-R500C-SIM-E |
1.Mountable Relays: G2RV-1-S-AP-G DC21V
2.Mountable Relays: G2RV-1-S-G DC21V
3.G2RV-1-S-AP-G Slim I/O Relays are mounted to G70V-SID16P(- 1) I/O Relay Terminals as a standard feature.
4.G2RV-1-S-G Slim I/O Relays are mounted to G70V-SOC16P(- 1) I/O Relay Terminals as a standard feature.
5.The operating characteristics are measured at a coil temperature of 23°C.
6.Measured at a coil temperature of 23°C with a tolerance of ±15% for coil resistance.
7.The rated current includes the current for the indicators on the I/O relay terminal.
8.The value for maximum voltage is the maximum value within the allowable voltage fluctuation range for the relay coil’s operating power supply. Continuous operation at this voltage is not within product specifications.
9.Measurement condition: 1 A at 5 VDC
10.Ambient temperature: 23°C