USD TERMINAL BLOCK
165041
16504-1
EATON-MOELLER
14
BLOCCO TERMINALE USD
Eaton Moeller series xPole - PL6 MCB. PL6, 3-pole+N, tripping characteristic: D, rated current In: 3 A, rated switching capacity IEC/EN 60898-1: 6 kA
Fusibili ad alta velocità serie Bussmann
Prodotto nuovo nel suo imballaggio d'origine con tutte le garanzie e certificazioni de EATON-MOELLER
Grazie per il suo interesse nei nostri prodotti, speriamo che il tempo di consegna indicato sia conveniente per lei.
Durante l’elaborazione dell’ordine potrà selezionare il tipo di invio che meglio si adatti alle sue necessità: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
| Product Name | Eaton Moeller series xPole - PL6 MCB |
| Catalog Number | 165041 |
| EAN | 4015081615513 |
| Product Length/Depth | 85 mm |
| Product Height | 73 mm |
| Product Width | 70 mm |
| Product Weight | 0.48 kg |
| Compliances | RoHS conform |
| Model Code | PL6-D3/3N |
| Application |
|
| Number of poles | Three-pole + N |
| Number of poles (total) | 4 |
| Number of poles (protected) | 3 |
| Tripping characteristic | D |
| Release characteristic | D |
| Amperage Rating | 3 A |
| Type |
|
| Voltage type | AC |
| Rated operational voltage (Ue) - max | 230 V |
| Rated insulation voltage (Ui) | 440 V |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Frequency rating - min | 50 Hz |
| Frequency rating - max | 60 Hz |
| Rated switching capacity (IEC/EN 60898-1) | 6 kA |
| Overvoltage category | III |
| Pollution degree | 2 |
| Width in number of modular spacings | 4 |
| Built-in depth | 69.5 mm |
| Degree of protection | IP20 |
| Connectable conductor cross section (solid-core) - min | 1 mm² |
| Connectable conductor cross section (solid-core) - max | 25 mm² |
| Connectable conductor cross section (multi-wired) - min | 1 mm² |
| Connectable conductor cross section (multi-wired) - max | 25 mm² |
| Rated operational current for specified heat dissipation (In) | 3 A |
| Heat dissipation per pole, current-dependent | 0 W |
| Equipment heat dissipation, current-dependent | 3.7 W |
| Static heat dissipation, non-current-dependent | 0 W |
| Heat dissipation capacity | 0 W |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 75 °C |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Current limiting class | 3 |
| Features | Concurrently switching N-neutral Additional equipment possible |
| Special features | Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity |
| Used with | Miniature circuit breaker PL6 |
| Titolo: | Dimensione: | Tipo: |
|---|---|---|
| PDF EATON CIRCUIT PROTECTION BUSSMANN EN .pdf | 23 Mbytes |
|
| PDF EATON CIRCUIT PROTECTION NH FUSE EN.pdf | 7 Mbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
Nessun commento per il momento.
| Valutazione: |
|
| Nome: | |
| Email: | |
| Titolo: | |
| Testo: | |
| Mi consiglia questo prodotto da acquistare? | |
|
|
|
| Inserisci recensione | |
Tutti i feedback che riceviamo dagli elementi che offriamo sono reali e verificati. Un piccolo gesto, ma di grande valore. Quindi grazie per quel minuto si spende in noi lasciare il vostro parere e punteggio sui prodotti, perché ci aiuta a continuare a migliorare e di offrire ancora maggiore qualità del servizio.