ANUNCIAR
M22-ASI-CS 231272 Y7-231272 EATON ELECTRIC ASI-Slave safety, 2I, 1Q, connessione a molla Visualizza ingrandito
Le immagini sono solo per fini illustrativi. Si prega di fare riferimento alla scheda tecnica p...

M22-ASI-CS 231272 Y7-231272 EATON ELECTRIC ASI-Slave safety, 2I, 1Q, connessione a molla

M22-ASI-CS

231272

Y7-231272

EATON-MOELLER

ASI-Slave safety, 2I, 1Q, connessione a molla

Modulo di sicurezza AS-Interface; 2I, 1Q; Connessione push-in

Eaton Moeller® series M22 ASI-Slave safety, 2I, 1Q, spring clamp connection

Accessori per il programma del dispositivo del circuito di controllo

Maggiori dettagli


Apparecchi elettrici a bassa tensione > adattatore per circuito di controllo

Ausili di controllo e segnalazione

Prodotto nuovo nel suo imballaggio d'origine con tutte le garanzie e certificazioni de EATON-MOELLER

Prezzo totale: $146.20
Prezzo unitario: $146.20
Questo prezzo è per unità e mostra il valore netto ( escluse le imposte indirette se applicabile ).

Se il nostro prezzo non è il migliore, chiedici un preventivo Richiedi un preventivo

Più venduti

Dettagli



General specifications

Product Name
Eaton Moeller® series M22 Accessory AS-Interface connection
Catalog Number
231272
EAN
4015082312725
Product Length/Depth
40 mm
Product Height
30 mm
Product Width
40 mm
Product Weight
0.017 kg
Certifications
EN 50178
EN 50295_x
IEC/EN 60947-5
UL 508
CSA
CSA Class No.: 3211-03
UL File No.: E29184
UL
CSA-C22.2 No. 14-05
UL Category Control No.: NKCR
CSA File No.: 012528
CE
CSA-C22.2 No. 94-91
Model Code
M22-ASI-CS

General

Current consumption
45 mA, max. total current, Emergency-Stop circuits
Degree of protection
IP00
Input
Inputs for 2 contact elements (M22-K01 (N/C), M22-K01 (N/O))
2-channel inputs (22 V/5 mA, AS-Interface, moduled by code sequence, 2 break contact sets RMQ-Titan M22-K01)
1 dual-channel input
Output
Output for 1 LED element: M22-LED-...
1 Output (19 V/8 mA), Emergency-Stop circuits, Short-circuit proof
1 Output
Product category
Accessories
Protocol
AS-Interface (S-7.B.E)

Ambient conditions, mechanical

Mounting position
As required
Shock resistance
Mechanical, According to IEC/EN 60068-2-27
30 g, Mechanical, According to IEC/EN 60068-2-27, Shock duration 11 ms

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78

Communication

Addressing
Address set via connection to AS-Interface cable
Connection to SmartWire-DT
No
Connection type
Base fixing for RMQ-Titan
LED indicator
Status indication of Power AS-Interface cable: Green LED on the back
Status indication of Error AS-Interface, failure of AS-Interface master: Red LED on the back

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
1.5 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 231272 Apparecchi elettrici a bassa tensione (EC001020)
Caratteristica Valore
diametro di montaggio (EF000943) 0 mm
numero di apparecchi incassabili (EF000219) 0

Datasheet - PDF

Recensioni: (0)

Nessun commento per il momento.

Inserisci recensione
nascondi form
Valutazione:
Nome:
Email:
Titolo:
Testo:
  Captcha
  Inserisci recensione

Tutti i feedback che riceviamo dagli elementi che offriamo sono reali e verificati. Un piccolo gesto, ma di grande valore. Quindi grazie per quel minuto si spende in noi lasciare il vostro parere e punteggio sui prodotti, perché ci aiuta a continuare a migliorare e di offrire ancora maggiore qualità del servizio.