ANUNCIAR
HN-C40/2 194875 Y7-194875 EATON ELECTRIC Miniature Circuit breaker 2-pole C-char 40-A Agrandir l'image
Les images sont à titre illustratif. Svp, révisez la fiche technique.

HN-C40/2 194875 Y7-194875 EATON ELECTRIC Miniature Circuit breaker 2-pole C-char 40-A

HN-C40/2

194875

Y7-194875

EATON-MOELLER

Miniature Circuit breaker 2-pole C-char 40-A

Int. disjoncteur Résidentiel, 2P, courbe C, 40A

Eaton Moeller series xPole Home - HN/HN-HX MCB. HN, xPole Home, 2-pole, tripping characteristic: C, rated current In: 40 A, rated switching capacity IEC/EN 60898-1: 6 kA

Disjoncteur miniature (MCB), HN, xPole Home, 2 pôles, caractéristique de déclenchement : C, courant nominal In : 40 A, puissance nominale de commutation selon IEC/EN 60898-1 : 6 kA, Appareillage pour applications résidentielles et commerciales

Plus de détails


Appareils de protection des installations, des équipements et des personnes > Disjoncteur

Appareillage Modulaire domestique

Produit neuf dans son emballage d'origine avec toutes les garanties et les certifications émises par EATON-MOELLER

Prix total: $26.03
Prix unitaire: $26.03
Ce prix est par unité et montre la valeur nette (excluant les taxes indirectes le cas échéant) .

Si notre prix n'est pas le meilleur, demandez-nous un devis. Demander un devis

Achetés habituellement ensemble

Les plus vendus

En savoir plus



Spécifications générales

Product Name
Eaton Moeller series xPole Home - HN/HN-HX MCB
Catalog Number
194875
Model Code
HN-C40/2
EAN
9010238063594
Product Length/Depth
85 mm
Product Height
73 mm
Product Width
35.4 mm
Product Weight
0.24 kg
Compliances
RoHS conform

Spécifications du produit

Type
Special features
Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity
Application
  • Switchgear for residential and commercial applications
  • xPole Home - Switchgear for residential applications
Amperage Rating
40 A
Features
Additional equipment possible
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Pollution degree
3
Used with
Miniature circuit breaker
HN
Degree of protection
IP20
Equipment heat dissipation, current-dependent
7.5 W
Rated impulse withstand voltage (Uimp)
4 kV
Tripping characteristic
C
Ambient operating temperature - max
75 °C
Ambient operating temperature - min
-25 °C
Built-in depth
44 mm
Connectable conductor cross section (multi-wired) - max
25 mm²
Connectable conductor cross section (multi-wired) - min
1 mm²
Connectable conductor cross section (solid-core) - max
25 mm²
Connectable conductor cross section (solid-core) - min
1 mm²
Current limiting class
3
Frequency rating - max
60 Hz
Frequency rating - min
50 Hz
Heat dissipation capacity
0 W
Heat dissipation per pole, current-dependent
0 W
Width in number of modular spacings
2
Voltage type
AC
Overvoltage category
III
Number of poles
Two-pole
Release characteristic
C
Number of poles (protected)
2
Number of poles (total)
2
Rated insulation voltage (Ui)
440 V
Rated operational current for specified heat dissipation (In)
40 A
Rated operational voltage (Ue) - max
230 V
Rated short-circuit breaking capacity (EN 60898) at 230 V
6 kA
Rated short-circuit breaking capacity (EN 60898) at 400 V
6 kA
Rated short-circuit breaking capacity (IEC 60947-2) at 230 V
0 kA
Rated short-circuit breaking capacity (IEC 60947-2) at 400 V
0 kA
Rated switching capacity (IEC/EN 60898-1)
6 kA
Static heat dissipation, non-current-dependent
0 W
Suitable for
Flush-mounted installation
Power loss
7.5 W

ETIM for 194875 Appareils de protection des installations, des équipements et des personnes (EC000042)
Caractéristique Valeur
Profondeur d'encastrement (EF000218) 44 mm
Caractéristique de déclenchement (EF000889) C
Nombre de pôles (total) (EF008618) 2
Nombre de pôles protégés (EF005548) 2
Courant nominal assigné (EF000227) 40 A
Tension assignée (EF000228) 230 V
Tension d'isolation assignée Ui (EF001366) 440 V
Tension nominale de tenue aux chocs Uimp (EF011980) 4 kV
Pouvoir de coupure assigné Icn selon EN 60898 à 230 V (EF009556) 6 kA
Type de tension (EF000187) CA
Pouvoir de coupure assigné Icn selon EN 60898 à 400 V (EF009555) 6 kA
Pouvoir de coupure assigné Icu selon IEC 60947-2 à 230 V (EF009557) 0 kA
Pouvoir de coupure assigné Icu selon IEC 60947-2 à 400 V (EF009558) 0 kA
Fréquence (EF000416) 50 Hz
Puissance dissipée (EF005387) 7.5 W
Classe de limitation d'énergie (EF002568) 3
Montage encastré (EF007517) Oui
Conducteur neutre branché simultanément (EF005997) Non
Catégorie de surtension (EF002569) 3
Degré de pollution (EF002570) 3
Dispositifs auxiliaires possibles (EF008148) Oui
Largeur dans les unités de partition (EF002950) 2
Classe de protection (IP) (EF005474) IP20
Température ambiante en fonctionnement (EF007515) -25 °C
Section de conducteur connectable multifilaire (EF007343) 1 mm²
Section de conducteur connectable monofilaire (EF007337) 1 mm²
Antidéflagration (EF004663) Non

Datasheet - PDF

Commentaires: (0)

Aucun commentaire sur le produit encore.

Écrire commentaire
Sous forme de peau
Score:
Nom:
Email:
Titre:
Commentaire:
  Captcha
  Écrire commentaire

Toutes les évaluations que nous recevons des articles que nous proposons sont réels et vérifiés. Un petit geste, mais très précieux. Je vous remercie pour cette minute que vous passez à nous laisser votre avis et note sur les produits, car il nous aide à continuer à améliorer et à offrir encore plus la qualité de service.