VGDILE48-C 230265 XTMCXVSCW EATON ELECTRIC Módulo supresor Varistor 48 V AC Conexión a presión Para contactor Ver más grande
Las imágenes son sólo a título ilustrativo. Por favor, revise la ficha técnica.

VGDILE48-C 230265 XTMCXVSCW EATON ELECTRIC Módulo supresor Varistor 48 V AC Conexión a presión Para contactor

VGDILE48-C

230265

XTMCXVSCW

EATON-MOELLER

10

Módulo supresor Varistor; 48 V AC; Conexión a presión; Para contactor

Eaton Moeller® series DILE Varistor suppressor, 48VAC, for DILE, spring clamp connection

Circuito supresor de varistor, Accesorios: Circuito supresor, Descripción: Supresor de varistor, Voltaje de actuación: Us 24 - 48 AC V, Para uso con: DILE...-C

Más detalles


Componentes industriales de baja tensión > Componente para circuito de protección

Accesorios KDIL

Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER

* Este artículo podría estar obsoleto. Si está interesado solicite presupuesto y le indicaremos si quedan unidades disponibles. En caso de que no queden uno de nuestros técnicos buscará una alternativa sumunistrable de características similares.

Si nuestro precio no es el mejor solicítenos presupuesto Solicitar presupuesto

Más vendidos

Más Información



Especificaciones generales

Product Name
Eaton Moeller® series DILE Accessory Varistor suppressor circuit
Catalog Number
230265
EAN
4015082302658
Product Length/Depth
16 mm
Product Height
29 mm
Product Width
33 mm
Product Weight
0.009 kg
Certifications
CSA-C22.2 No. 14-05
CE
UL
CSA
IEC/EN 60947-4-1
CSA Class No.: 3211-03
CSA File No.: 012528
UL File No.: E29096
UL 508
UL Category Control No.: NLDX
Model Code
VGDILE48-C

Características y Funciones

Functions
Varistor (voltage-sensitive resistor)

General

Product category
Accessories
Used with
DILE…-C
Voltage type
AC

Condiciones climáticas ambientales

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
50 °C

Sistema magnético

Rated control supply voltage (Us) at AC, 50 Hz - min
48 V
Rated control supply voltage (Us) at AC, 50 Hz - max
48 V
Rated control supply voltage (Us) at AC, 60 Hz - min
48 V
Rated control supply voltage (Us) at AC, 60 Hz - max
48 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V

Verificación del diseño

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 230265 Interruptores de baja tensión (EC000683)
Característica Valor
Función (EF000030) Varistor (resistencia sensible a la tensión)
Tipo de tensión de funcionamiento (EF005294) CA
Voltaje de funcionamiento a 50 Hz CA (EF008206) 24 V
Voltaje de funcionamiento a 60 Hz CA (EF008207) 24 V
Voltaje de funcionamiento en CC (EF008208) 0 V
Con indicador LED (EF005950) No

Datasheet - PDF

Opiniones: (0)

Ningún comentario por el momento.

Añadir comentario
ocultar
Valoración:
Nombre:
Email:
Título:
Opinión:
  Captcha
  Añadir comentario

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.