1
Convertidor de frecuencia, 5.6 A, 2.2 kW, 4 entradas sensor, 2 Salidas
Eaton Moeller® series Rapid Link - Speed controllers, 5.6 A, 2.2 kW, Sensor input 4, Actuator output 2, 180/207 V DC, Ethernet IP, HAN Q4/2, with manual override switch, with braking resistance, STO (Safe Torque Off)
Reguladores de velocidad, 5,6 A, 2,2 kW, Entrada de sensor 4, Salida de actuador 2, 180/207 V DC, Ethernet IP, HAN Q4/2, con interruptor de anulación manual, con resistencia de frenado, STO (Safe Torque Off)
Componentes industriales de baja tensión > Convertidor de frecuencia de menos de 1 kV
Arrancadores Rapid Link
Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER
Gracias por su interés en nuestros productos, esperamos que el plazo indicado sea conveniente para usted.
Durante la tramitación del pedido podrá seleccionar el tipo de envío que mejor se adapte a sus necesidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
| Product Name | Eaton Rapid Link Speed controller |
| Catalog Number | 198913 |
| EAN | 4015081969715 |
| Product Length/Depth | 157 mm |
| Product Height | 270 mm |
| Product Width | 220 mm |
| Product Weight | 3.61 kg |
| Certifications | UL approval CE RoHS IEC/EN 61800-5-1 UL 61800-5-1 |
| Catalog Notes |
|
| Model Code | RASP5-5421EIP-412R110S1 |
| Features | Parameterization: drivesConnect mobile (App) Parameterization: Keypad Parameterization: drivesConnect Parameterization: Fieldbus |
| Fitted with: | Key switch position AUTO Thermo-click with safe isolation Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation Control unit Key switch position OFF/RESET Braking resistance PTC thermistor monitoring Manual override switch Internal DC link PC connection Breaking resistance Key switch position HAND Selector switch (Positions: REV - OFF - FWD) IGBT inverter 2 Actuator outputs |
| Functions | Brake chopper with braking resistance for dynamic braking 1 potentiometer speed 4-quadrant operation possible For actuation of motors with mechanical brake STO (Safe Torque Off) 3 fixed speeds |
| Degree of protection | NEMA 12 IP65 |
| Electromagnetic compatibility | 1st and 2nd environments (according to EN 61800-3) |
| Overvoltage category | III |
| Product category | Speed controller |
| Product category | Speed controller |
| Protocol | EtherNet/IP |
| Radio interference class | C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. C1: for conducted emissions only |
| Rated impulse withstand voltage (Uimp) | 2000 V |
| System configuration type | AC voltage Center-point earthed star network (TN-S network) Phase-earthed AC supply systems are not permitted. |
| Mounting position | Vertical |
| Shock resistance | 15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaft |
| Vibration | Resistance: 10 - 150 Hz, Oscillation frequency Resistance: According to IEC/EN 60068-2-6 Resistance: 57 Hz, Amplitude transition frequency on acceleration Resistance: 6 Hz, Amplitude 0.15 mm |
| Altitude | Max. 2000 m Above 1000 m with 1 % performance reduction per 100 m |
| Ambient operating temperature - min | -10 °C |
| Ambient operating temperature - max | 40 °C |
| Ambient storage temperature - min | -40 °C |
| Ambient storage temperature - max | 70 °C |
| Climatic proofing | < 95 %, no condensation In accordance with IEC/EN 50178 |
| Current limitation | Adjustable, motor, main circuit 0.5 - 5.6 A, motor, main circuit |
| Delay time | < 10 ms, Off-delay < 10 ms, On-delay |
| Efficiency | 98 % (η) |
| Heat dissipation at current/speed | 36.6 W at 25% current and 0% speed 38.1 W at 25% current and 50% speed 42 W at 50% current and 0% speed 42.5 W at 50% current and 90% speed 44.2 W at 50% current and 50% speed 55.9 W at 100% current and 0% speed 58.3 W at 100% current and 90% speed 60.4 W at 100% current and 50% speed |
| Input current ILN at 150% overload | 5.3 A |
| Leakage current at ground IPE - max | 3.5 mA |
| Mains current distortion | 120 % |
| Mains switch-on frequency | Maximum of one time every 60 seconds |
| Mains voltage - max | 480 V |
| Mains voltage - min | 380 V |
| Mains voltage tolerance | 380 - 480 V (-10 %/+10 %, at 50/60 Hz) |
| Operating mode | PM and LSPM motors Synchronous reluctance motors BLDC motors U/f control Sensorless vector control (SLV) |
| Output frequency - max | 500 Hz |
| Output frequency - min | 0 Hz |
| Overload current | For 60 s every 600 s At 40 °C |
| Overload current IL at 150% overload | 8.4 A |
| Rated frequency - max | 66 Hz |
| Rated frequency - min | 45 Hz |
| Rated operational current (Ie) | 5.6 A at 150% overload (at an operating frequency of 8 kHz and an ambient air temperature of +40 °C) |
| Rated operational power at 380/400 V, 50 Hz, 3-phase | 1.5 kW |
| Rated operational voltage | 400 V AC, 3-phase 480 V AC, 3-phase |
| Resolution | 0.1 Hz (Frequency resolution, setpoint value) |
| Starting current - max | 200 %, IH, max. starting current (High Overload), For 2 seconds every 20 seconds, Power section |
| Supply frequency | 50/60 Hz |
| Switching frequency | 8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuit |
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 3 HP |
| Braking current | ≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake |
| Braking torque | ≤ 30 % (I/Ie) Adjustable to 100 % (I/Ie), DC - Main circuit |
| Braking voltage | 280/207 V DC -15 % / +10 %, Actuator for external motor brake |
| Switch-on threshold for the braking transistor | 765 VDC |
| Rated conditional short-circuit current (Iq) | 10 kA |
| Short-circuit protection (external output circuits) | Type 1 coordination via the power bus' feeder unit, Main circuit |
| Rated control voltage (Uc) | 180/207 V DC (external brake 50/60 Hz) 24 V DC (-15 %/+20 %, external via AS-Interface® plug) |
| Communication interface | Ethernet IP, built in |
| Connection | Plug type: HAN Q4/2 |
| Interfaces | Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA Specification: S-7.4 (AS-Interface®) Number of slave addresses: 31 (AS-Interface®) |
| Cable length | C3 ≤ 25 m, maximum motor cable length C2 ≤ 5 m, maximum motor cable length C1 ≤ 1 m, maximum motor cable length |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Característica | Valor |
|---|---|
| Tensión de red (EF006780) | 380 V |
| Frecuencia de la red (EF006783) | 50/60 Hz |
| Número de fases de entrada (EF007117) | 3 |
| Número de salidas de fase (EF006998) | 3 |
| Frecuencia máxima de salida (EF007350) | 500 Hz |
| Tensión de salida máx. (EF009560) | 500 V |
| Corriente de salida nominal I2N (EF009561) | 5.6 A |
| Potencia cuadrática máxima entregada. Carga a la tensión nominal de entrada (EF007366) | 2.2 kW |
| Potencia de salida máxima en carga lineal a tensión de salida nominal (EF007364) | 2.2 kW |
| Consumo de energía (EF000346) | 58 W |
| Tolerancia de frecuencia de potencia simétrica relativa (EF007454) | 10 % |
| Tolerancia de tensión de red simétrica relativa (EF007453) | 10 % |
| Número de salidas analógicas (EF001995) | 0 |
| Número de entradas analógicas (EF001994) | 0 |
| Número de salidas digitales (EF001993) | 2 |
| Número de entradas digitales (EF001992) | 4 |
| Con unidad de control (EF001538) | Sí |
| Uso en el sector industrial permitido (EF007294) | Sí |
| Uso permitido en zonas residenciales y comerciales (EF007295) | Sí |
| Soporta el protocolo TCP/IP (EF003050) | No |
| Soporta el protocolo PROFIBUS (EF003052) | No |
| Soporta el protocolo CAN (EF003053) | No |
| Soporta el protocolo INTERBUS (EF003054) | No |
| Soporta el protocolo ASI (EF003051) | No |
| Soporta protocolo KNX (EF003055) | No |
| Soporta el protocolo Modbus (EF003057) | No |
| Soporta el protocolo de autopista de datos (EF003058) | No |
| Soporta el protocolo DeviceNet (EF003059) | No |
| Soporta el protocolo SUCONET (EF003060) | No |
| Soporta el protocolo LON (EF003017) | No |
| Soporta el protocolo PROFINET IO (EF007525) | No |
| Soporta el protocolo PROFINET CBA (EF007524) | No |
| Soporta el protocolo SERCOS (EF006657) | No |
| Soporta el protocolo Foundation Fieldbus (EF007522) | No |
| Soporta el protocolo Ethernet/IP (EF007521) | Sí |
| Soporta el protocolo AS-Interface Safety at Work (EF007519) | No |
| Soporta el protocolo DeviceNet Safety (EF007520) | No |
| Soporta el protocolo de seguridad INTERBUS (EF006662) | No |
| Soporta el protocolo PROFIsafe (EF007526) | No |
| Soporta el protocolo SafetyBUS p (EF007527) | No |
| Soporta protocolo para BACnet (EF011944) | No |
| Soporta el protocolo para otros sistemas bus (EF003062) | No |
| Número de interfaces HW Ethernet industrial (EF003020) | 2 |
| Número de interfaces PROFINET (EF006932) | 0 |
| Número de interfaces HW RS232 (EF003021) | 0 |
| Número de interfaces HW RS422 (EF003022) | 0 |
| Número de interfaces HW RS485 (EF003023) | 1 |
| Número de interfaces HW en serie TTY (EF003024) | 0 |
| Número de interfaces HW USB (EF003025) | 0 |
| Número de interfaces HW en paralelo (EF003026) | 0 |
| Número de interfaces HW Otras (EF003027) | 0 |
| Con interfaz óptica (EF003028) | No |
| Con conexión a PC (EF006107) | Sí |
| Resistencia de frenado integrada (EF007293) | Sí |
| Operación de 4 cuadrantes posible (EF006803) | Sí |
| Tipo de convertidor (EF006978) | Convertidor U |
| Grado de protección (IP) (EF005474) | IP65 |
| Grado de protección (NEMA) (EF011959) | 12 |
| Altura (EF000040) | 270 mm |
| Anchura (EF000008) | 220 mm |
| Profundidad (EF000049) | 157 mm |
| Título: | Tamaño: | Tipo: |
|---|---|---|
| PDF EATON STARTING CONTROLLING MOTORS EN.pdf | 37 Mbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
Ningún comentario por el momento.
| Valoración: |
|
| Nombre: | |
| Email: | |
| Título: | |
| Opinión: | |
| ¿Recomienda la compra de este producto? | |
|
|
|
| Añadir comentario | |
Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.