ANUNCIAR
PKE-XHT-MCC 164299 Y7-164299 EATON ELECTRIC Maneta para montaje en puert A Negra Para CCM 90° Para PKE Ver más grande
Las imágenes son sólo a título ilustrativo. Por favor, revise la ficha técnica.

PKE-XHT-MCC 164299 Y7-164299 EATON ELECTRIC Maneta para montaje en puert A Negra Para CCM 90° Para PKE

PKE-XHT-MCC

164299

Y7-164299

EATON-MOELLER

Maneta para montaje en puert A, Negra, Para CCM, 90°, Para PKE

Eaton Moeller® series PKE Door coupling handle, for MCC-V, 90 degree, twisted

Para su uso como interruptor principal según la norma EN 60204 en sistemas de distribución de energía MCC y con PKZM0 instalado cuando se gira 90°

Más detalles


Componentes industriales de baja tensión > Accionamiento manual de dispositivos de conmutación

Interruptores Protectores de Motor Electrónicos

Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER

Precio total: $125.48
Precio unitario: $125.48
Este precio es por unidad y muestra el valor neto (no incluye impuestos indirectos si son aplicables).

Si nuestro precio no es el mejor solicítenos presupuesto Solicitar presupuesto

productos relacionados

Más vendidos

Más Información



Especificaciones generales

Product Name
Eaton Moeller® series PKE Door coupling handle
Catalog Number
164299
EAN
4015081608270
Product Length/Depth
235 mm
Product Height
66 mm
Product Width
64 mm
Product Weight
0.16 kg
Certifications
EN 60204
Catalog Notes
Cannot be used in combination with VHI20-PKZ0.
Model Code
PKE-XHT-MCC

Características y Funciones

Color
Black
Features
Lockable
Fitted with:
Door interlock
3 padlocks, 4 - 8 mm hasp thickness
ON/OFF switch position and “+” (tripped), lockable
Axis extension

General

Degree of protection
IP65
NEMA Other
Product Category
Accessories
Suitable as
Main switch to EN 60204 in MCC power distribution systems and with PKE installed when rotated by 90°

Condiciones climáticas ambientales

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C

Verificación del diseño

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
Not applicable.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 164299 Interruptores de baja tensión (EC000230)
Característica Valor
Con extensión de eje (EF001968)
Con cerradura de puerta (EF001969)
Bloqueable (EF000113)
Con asa roja/amarilla (EF001970) No
Grado de protección (NEMA) (EF011959) Otros

Datasheet - PDF

Opiniones: (0)

Ningún comentario por el momento.

Añadir comentario
ocultar
Valoración:
Nombre:
Email:
Título:
Opinión:
  Captcha
  Añadir comentario

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.