Producto añadido correctamente a su carrito de la compra
P1-25/SE1/SVB
197346
Y7-197346
EATON-MOELLER
1
Interruptor General, 25A, montaje en superficie, 3p,
Eaton Moeller® series P1 Main switch, P1, 25 A, surface mounting, 3 pole, Emergency switching off function, With red rotary handle and yellow locking ring, Lockable in the 0 (Off) position, in steel enclosure
Interruptor principal, P1, Corriente nominal ininterrumpida (Iu): 25 A, Funciones: Función de desconexión de emergencia, Enclavable, Equipado con: Mango giratorio rojo y anillo de bloqueo amarillo, Método de montaje: Montaje en superficie, Número de polos: Tres polos, Dispositivo de bloqueo: Bloqueable en la posición 0 (Apagado), Grado de protección: NEMA 12
Componentes industriales de baja tensión > Seccionador
Interruptores Seccionadores y de Levas
Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER
Gracias por su interés en nuestros productos, esperamos que el plazo indicado sea conveniente para usted.
Durante la tramitación del pedido podrá seleccionar el tipo de envío que mejor se adapte a sus necesidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
| Product Name | Eaton Moeller® series P1 Main switch |
| Catalog Number | 197346 |
| EAN | 4015080896906 |
| Product Length/Depth | 200 mm |
| Product Height | 135 mm |
| Product Width | 150 mm |
| Product Weight | 1.65 kg |
| Certifications | IEC/EN 60947-3 VDE 0660 IEC/EN 60947 IEC/EN 60204 |
| Model Code | P1-25/SE1/SVB |
| Features | Version as maintenance-/service switch Version as main switch Version as safety switch Version as emergency stop installation |
| Fitted with: | Red rotary handle and yellow locking ring |
| Functions | Emergency switching off function Interlockable |
| Locking facility | Lockable in the 0 (Off) position |
| Number of poles | Three-pole |
| Accessories | Auxiliary contact or neutral conductor fitted by user. |
| Degree of protection | NEMA 12 |
| Degree of protection (front side) | IP65 |
| Lifespan, mechanical | 300,000 Operations |
| Mounting method | Surface mounting |
| Mounting position | As required |
| Operating frequency | 1200 Operations/h |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product Category | Main switch |
| Product Category | Main switch |
| Rated impulse withstand voltage (Uimp) | 6000 V AC |
| Safe isolation | 440 V AC, Between the contacts, According to EN 61140 |
| Safety parameter (EN ISO 13849-1) | B10d values as per EN ISO 13849-1, table C.1 |
| Shock resistance | 15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms |
| Suitable for | Ground mounting |
| Switching angle | 90 ° |
| Ambient operating temperature (enclosed) - min | -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Screw size | M4, Terminal screw |
| Tightening torque | 1.6 Nm, Screw terminals 14 Nm, Screw terminals |
| Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3) | 190 A |
| Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3) | 150 A |
| Rated breaking capacity at 500 V (cos phi to IEC 60947-3) | 170 A |
| Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3) | 150 A |
| Rated operational current (Ie) at AC-21, 440 V | 25 A |
| Rated operational current (Ie) at AC-23A, 230 V | 25 A |
| Rated operational current (Ie) at AC-23A, 400 V, 415 V | 25 A |
| Rated operational current (Ie) at AC-23A, 500 V | 17.4 A |
| Rated operational current (Ie) at AC-23A, 690 V | 12 A |
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 19.6 A |
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 15.2 A |
| Rated operational current (Ie) at AC-3, 500 V | 12.1 A |
| Rated operational current (Ie) at AC-3, 660 V, 690 V | 8.8 A |
| Rated operational current (Ie) at DC-1, load-break switches l/r = 1 ms | 25 A |
| Rated operational current (Ie) at DC-23A, 24 V | 25 A |
| Number of contacts in series at DC-23A, 24 V | 1 |
| Rated operational current (Ie) at DC-23A, 48 V | 25 A |
| Number of contacts in series at DC-23A, 48 V | 2 |
| Rated operational current (Ie) at DC-23A, 60 V | 25 A |
| Number of contacts in series at DC-23A, 60 V | 2 |
| Rated operational current (Ie) at DC-23A, 120 V | 12 A |
| Number of contacts in series at DC-23A, 120 V | 3 |
| Rated operational power at AC-23A, 220/230 V, 50 Hz | 5.5 kW |
| Rated operational power at AC-23A, 400 V, 50 Hz | 13 kW |
| Rated operational power at AC-23A, 500 V, 50 Hz | 11 kW |
| Rated operational power at AC-23A, 690 V, 50 Hz | 11 kW |
| Rated operational power at AC-3, 380/400 V, 50 Hz | 7.5 kW |
| Rated operational power at AC-3, 415 V, 50 Hz | 7.5 kW |
| Rated operational power at AC-3, 690 V, 50 Hz | 7.5 kW |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Rated uninterrupted current (Iu) | 25 A |
| Uninterrupted current | Rated uninterrupted current Iu is specified for max. cross-section. |
| Voltage per contact pair in series | 60 V |
| Rated conditional short-circuit current (Iq) | 50 kA |
| Rated short-time withstand current (Icw) | 0.64 kA 640 A, Contacts, 1 second |
| Short-circuit protection rating | 25 A gG/gL, Fuse, Contacts |
| Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3) | 240 A |
| Load rating | 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor) 2 x Iₑ (with intermittent operation class 12, 25 % duty factor) 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor) |
| Control circuit reliability | 1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA) |
| Number of auxiliary contacts (change-over contacts) | 0 |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Actuator color | Red |
| Actuator type | Door coupling rotary drive |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | UV resistance only in connection with protective shield. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Característica | Valor |
|---|---|
| Ejecución como interruptor principal (EF006981) | Sí |
| Ejecución como interruptor de mantenimiento/reparación (EF006986) | Sí |
| Ejecución como interruptor de seguridad (EF006985) | Sí |
| Ejecución como dispositivo de parada de emergencia (EF006959) | Sí |
| Ejecución como conmutador-inversor (EF009408) | No |
| Número de interruptores (EF005586) | 1 |
| Tensión de funcionamiento nominal máxima Ue CA (EF007355) | 690 V |
| Tensión nominal de funcionamiento (EF001435) | 690 V |
| Intensidad nominal permanente Iu (EF001389) | 25 A |
| Corriente permanente asignada a AC-23, 400 V (EF011777) | 25 A |
| Corriente permanente asignada con AC-21, 400 V (EF009165) | 25 A |
| Potencia de funcionamiento nominal en CA-3, 400 V (EF001364) | 7.5 kW |
| Resistencia de corriente nominal de corta duración Icw (EF007050) | 0.64 kA |
| Potencia de funcionamiento nominal a 400 V CA-23 (EF007027) | 13 kW |
| Poder de corte a 400 V (EF009166) | 11 kW |
| Corriente nominal de cortocircuito condicional Iq (EF001444) | 50 kA |
| Número de polos (EF001391) | 3 |
| Número de contactos auxiliares normalmente cerrados (EF001377) | 0 |
| Número de contactos auxiliares normalmente abiertos (EF001376) | 0 |
| Número de contactos auxiliares como contacto de cambio (EF003531) | 0 |
| Accionamiento motorizado opcional (EF007386) | No |
| Accionamiento motorizado integrado (EF006697) | No |
| Liberación de tensión opcional (EF007491) | No |
| Construcción del dispositivo (EF008240) | Dispositivo completo en carcasa |
| Apto para montaje frontal de 4 orificios (EF007247) | No |
| Apto para montaje frontal central (EF007248) | No |
| Apto para la instalación del distribuidor (EF007262) | No |
| Apto para montaje intermedio (EF007264) | No |
| Color del elemento de accionamiento (EF007167) | Rojo |
| Ejecución del elemento accionador (EF006976) | Dispositivo giratorio de acoplamiento a la puerta |
| Interbloqueable (EF006281) | Sí |
| Tipo de conexión del circuito de corriente principal (EF006819) | Conexión roscada |
| Con cableado premontado (EF016444) | No |
| Grado de protección (IP), frontal (EF003118) | IP65 |
| Grado de protección (NEMA) (EF011959) | 12 |
| Anchura (EF000008) | 150 mm |
| Altura (EF000040) | 135 mm |
| Profundidad (EF000049) | 200 mm |
| Título: | Tamaño: | Tipo: |
|---|---|---|
| PDF CATALOGO EATON CONTROL Y AUTOMATIZACION ES.pdf | 9 Mbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| P1-25/SE1/SVB Y7-197346 197346 ES_197348.pdf | 1 Mbytes |
![]() |
Ningún comentario por el momento.
| Valoración: |
|
| Nombre: | |
| Email: | |
| Título: | |
| Opinión: | |
| ¿Recomienda la compra de este producto? | |
|
|
|
| Añadir comentario | |
Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.