EU5E-SWD-4PT-2 172560 EATON ELECTRIC Módulo SWDT IP20 4 Entradas Temperatura Configurable Pt100/Pt1000/Ni1000 Ver más grande
Las imágenes son sólo a título ilustrativo. Por favor, revise la ficha técnica.

EU5E-SWD-4PT-2 172560 EATON ELECTRIC Módulo SWDT IP20 4 Entradas Temperatura Configurable Pt100/Pt1000/Ni1000

EU5E-SWD-4PT-2

172560

EATON-MOELLER

Módulo SWDT IP20; 4 Entradas Temperatura; Configurable Pt100/Pt1000/Ni1000

Módulo SWDT IP20 4 Entradas Temperatura Configurable

Eaton EU5E SmartWire-DT I/O module, 24 V DC, 4 AI configurable Pt100 / Pt1000: -100 - +400°C, Ni1000: -50 - +200 °C

Más detalles


Controladores industriales (PLC) > Módulo de E/S analógica de periférico descentralizado de bus de campo

Smartwire Darwin

* Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER

Precio total: $316.75
Precio unitario: $316.75

Cantidad Precio
1+$316.75
2+$299.17
3+$299.17
*Este precio es por unidad y muestra el valor neto (no incluye impuestos indirectos si son aplicables).

Si nuestro precio no es el mejor solicítenos presupuesto Solicitar presupuesto

Más Información



Especificaciones generales

Product Name
Eaton EU5E Accessory Input module
Catalog Number
172560
EAN
4015081691050
Product Length/Depth
102 mm
Product Height
90 mm
Product Width
35 mm
Product Weight
0.16 kg
Certifications
CSA File No.: 2324643
CSA Class No.: 3211-07
UL File No.: E29184
IEC/EN 61131-2
UL
UL Category Control No.: NKCR
CSA
Model Code
EU5E-SWD-4PT-2

Características y funciones

Electric connection type
Flat plug-in connection
Features
Fieldbus connection over separate bus coupler possible
Analog outputs configurable
Input, resistance thermometer
Analog inputs configurable
Fitted with:
Temperature sensors PT100, PT1000 and Ni1000
Display mode for temperatures (°C, °F, raw value)
Functions
Adjustable parameter settings
For connection of analog I/O signals

General

Current consumption
22 mA, SmartWire-DT network
Degree of protection
IP20
NEMA 1
Mounting method
Rail mounting possible
Wall mounting/direct mounting
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Overvoltage category
II
Pollution degree
2
Product category
SmartWire-DT slave
Repetition accuracy
0.5 % (Temperature inputs)
Residual ripple
≤ 5 % (input voltage)
Terminal capacity
0.25 - 1.5 mm² (24 - 16 AWG), flexible with ferrule, Terminal for I/O sensor
0.2 - 1.5 mm² (AWG 24 - 16), solid, Terminal for I/O sensor
Type
Analog modules
Voltage type
DC

Condiciones ambientales y mecánicas

Constant acceleration
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
As required
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts

Condiciones climáticas ambientales

Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-3
Dry heat to IEC 60068-2-2
Environmental conditions
Condensation: prevent with appropriate measures
Operating temperature - min
-100 °C
Operating temperature - max
55 °C
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)

Compatibilidad electromagnética

Air discharge
8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse
2 kV, Signal cable, according to IEC/EN 61131-2, Level 3
2 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3
Contact discharge
4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008)
Radiated RFI
10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference class
Class B (EN 55011)
Surge rating
1 kV, Surge I/O cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
1 kV, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC

Especificaciones eléctricas

Power loss
0.6 W
Rated operational voltage
24 V DC (-15 %/+ 20 % - power supply)
Supply voltage at AC, 50 Hz - min
0 VAC
Supply voltage at AC, 50 Hz - max
0 VAC
Supply voltage at DC - min
0 VDC
Supply voltage at DC - max
0 VDC

Comunicación

Connection to SmartWire-DT
Yes
Connection type
Pin contact, 8 pole
Push in terminals, Supply and I/O sensor
Connector: external device plug SWD4-8SF2-5, SmartWire-DT
Data transfer rate
Setting automatically
250 kBit/s, SmartWire-DT
LED indicator
Status indication of SmartWire-DT network: Green LED
Protocol
Other bus systems
Station
SmartWire-DT slave, SmartWire-DT network

Entrada/salida

Conversions
250 ms, Temperature inputs
Input
Inputs, configurable (PT100, PT1000, Ni1000)
Number of inputs (analog)
4
Number of outputs (analog)
0
Resolution
0.1 °C, Temperature inputs
Total error
± 1 %, Temperature Inputs

Seguridad

Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Inputs for SmartWire-DT: yes
Protection against polarity reversal
Yes

Verificación del diseño

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0.6 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Datasheet - PDF

Opiniones: (0)

Ningún comentario por el momento.

Añadir comentario
ocultar
Valoración:
Nombre:
Email:
Título:
Opinión:
  Captcha
  Añadir comentario

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.