10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Fitted with:
Built-in suppressor circuit
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
AC-3: Normal AC induction motors: starting, switch off during running
Ambient operating temperature - max
Ambient operating temperature - min
Assigned motor power at 115/120 V, 60 Hz, 1-phase
Assigned motor power at 200/208 V, 60 Hz, 3-phase
Assigned motor power at 230/240 V, 60 Hz, 1-phase
Assigned motor power at 230/240 V, 60 Hz, 3-phase
Assigned motor power at 460/480 V, 60 Hz, 3-phase
Assigned motor power at 575/600 V, 60 Hz, 3-phase
Conventional thermal current ith (1-pole, enclosed)
Conventional thermal current ith (3-pole, enclosed)
Conventional thermal current ith of main contacts (1-pole, open)
Equipment heat dissipation, current-dependent Pvid
Heat dissipation capacity Pdiss
Heat dissipation per pole, current-dependent Pvid
Application
Contactors for Semiconductor Industries acc. to SEMI F47
Electrical connection type of main circuit
Number of auxiliary contacts (normally closed contacts)
Number of auxiliary contacts (normally open contacts)
Number of contacts (normally closed) as main contact
Number of contacts (normally open contacts)
Number of main contacts (normally open contact)
Rated control supply voltage (Us) at AC, 50 Hz - max
Rated control supply voltage (Us) at AC, 50 Hz - min
Rated control supply voltage (Us) at AC, 60 Hz - max
Rated control supply voltage (Us) at AC, 60 Hz - min
Drop-out voltage
AC operated: 0.5 - 0.2 x UC, AC operated
Power consumption, pick-up, 50 Hz
14 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Power consumption, sealing, 50 Hz
0.7 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
0.8 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Switching capacity (auxiliary contacts, general use)
10 A, 600 V AC, (UL/CSA)
1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)
A600, AC operated (UL/CSA)
P300, DC operated (UL/CSA)
Switching capacity (main contacts, general use)
40 A, Maximum motor rating (UL/CSA)
Rated control supply voltage (Us) at DC - max
Rated control supply voltage (Us) at DC - min
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
Rated operational current (Ie) at AC-3, 440 V
Rated operational current (Ie) at AC-3, 500 V
Rated operational current (Ie) at AC-3, 660 V, 690 V
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
Rated operational current (Ie) at AC-4, 400 V
Rated operational current (Ie) at AC-4, 440 V
Rated operational current (Ie) at AC-4, 500 V
Rated operational current (Ie) at AC-4, 660 V, 690 V
Rated operational current for specified heat dissipation (In)
Rated operational power at AC-3, 240 V, 50 Hz
Rated operational power at AC-3, 380/400 V, 50 Hz
Rated operational power at AC-3, 415 V, 50 Hz
Rated operational power at AC-4, 220/230 V, 50 Hz
Rated operational power at AC-4, 240 V, 50 Hz
Rated operational power at AC-4, 380/400 V, 50 Hz
Rated operational power at AC-4, 415 V, 50 Hz
Rated operational power at AC-4, 440 V, 50 Hz
Rated operational power at AC-4, 500 V, 50 Hz
Rated operational power at AC-4, 660/690 V, 50 Hz
Rated operational power (NEMA)
Static heat dissipation, non-current-dependent Pvs
Switching time (AC operated, make contacts, closing delay) - max
Switching time (AC operated, make contacts, opening delay) - max
Short-circuit current rating (basic rating)
125 A, max. Fuse, SCCR (UL/CSA)
5 kA, SCCR (UL/CSA)
125 A, max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)
10/65 kA, CB, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
125/70 A, Class J, max. Fuse, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)
10/100 kA, Fuse, SCCR (UL/CSA)
125/100 A, Class J, max. Fuse, SCCR (UL/CSA)
10/22 kA, CB, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
Suitable for
SEMI F47, Magnet systems
Also motors with efficiency class IE3
Special purpose rating of ballast electrical discharge lamps
40 A (600V 60Hz 3phase, 347V 60Hz 1phase)
40 A (480V 60Hz 3phase, 277V 60Hz 1phase)
Special purpose rating of definite purpose rating
25 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
150 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control
14 A, 480 V 60 Hz 3-ph, (UL/CSA)
15 HP, 600 V 60 Hz 3-ph, (UL/CSA)
11 A, 200 V 60 Hz 3-ph, (UL/CSA)
10 HP, 480 V 60 Hz 3-ph, (UL/CSA)
17 A, 600 V 60 Hz 3-ph, (UL/CSA)
15.2 A, 240 V 60 Hz 3-ph, (UL/CSA)
3 HP, 200 V 60 Hz 3-ph, (UL/CSA)
5 HP, 240 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)
180 A, LRA 600 V 60 Hz 3phase; (CSA)
40 A, FLA 480 V 60 Hz 3phase; (CSA)
30 A, FLA 600 V 60 Hz 3phase; (CSA)
240 A, LRA 480 V 60 Hz 3phase; (CSA)
Special purpose rating of resistance air heating
40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of tungsten incandescent lamps
40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Conventional thermal current ith at 40°C (3-pole, open)
Conventional thermal current ith at 50°C (3-pole, open)
Conventional thermal current ith at 60°C (3-pole, open)
Rated operational power at AC-3, 440 V, 50 Hz
Rated operational power at AC-3, 500 V, 50 Hz
Rated operational power at AC-3, 690 V, 50 Hz
Actuating voltage
RAC 48: 42 - 48 V 50/60 Hz
Operating voltage at AC, 50 Hz - min
Operating voltage at AC, 50 Hz - max
Operating voltage at AC, 60 Hz - min
Operating voltage at AC, 60 Hz - max