ANUNCIAR
DILDC400/22(RDS250) 186872 Y7-186872 EATON ELECTRIC Contactor DC 2 polos + 2 NO + 2 NC 400 A DC-1 1000 V RDS.. Ver más grande
Las imágenes son sólo a título ilustrativo. Por favor, revise la ficha técnica.

DILDC400/22(RDS250) 186872 Y7-186872 EATON ELECTRIC Contactor DC 2 polos + 2 NO + 2 NC 400 A DC-1 1000 V RDS..

DILDC400/22(RDS250)

186872

Y7-186872

EATON-MOELLER

Contactor DC, 2 polos + 2 NO + 2 NC, 400 A, DC-1, 1000 V, RDS250

Eaton Moeller® series DILDC DC contactor, 2 N/O, 2 NC, 1000 V: 400 A, RDS 250: 110 - 250 V 40 - 60 Hz/110 - 350 V DC, AC and DC operation

Contactor de CC, dispositivo para los mercados mundiales: UL/CSA, CCC, dimensiones compactas, serie de confort con la opción de ser accionado directamente a través de PLC, con circuito supresor integrado en la electrónica de actuación, conforme a IEC/EN 60947, con bobina de amplio rango de voltaje CA/CC, controlado electrónicamente, potencia de recogida y retención minimizada, compatibilidad electromagnética mejorada, conexiones de cable de control con terminales de tornillo, 2 N/O 2 contactos auxiliares N/C instalados, aislamiento seguro según EN 61140, contactos opuestos entrelazados, fijación atornillada, utilizable hasta 1000 V, grado de protección IP00, seguro para los dedos con tapa de bornes según EN 50274 , vida mecánica de 1 millón de operaciones de conmutación, accesorios disponibles: módulo de contacto auxiliar de montaje lateral

Más detalles


Componentes industriales de baja tensión > Contactor de potencia para conmutación de corriente continua

Contactores más de 170 A

Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER

Precio total: $5,411.12
Precio unitario: $5,411.12
Este precio es por unidad y muestra el valor neto (no incluye impuestos indirectos si son aplicables).

Si nuestro precio no es el mejor solicítenos presupuesto Solicitar presupuesto

productos relacionados

Más vendidos

Más Información



Especificaciones generales

Product Name
Eaton Moeller® series DILDC DC Contactor
Catalog Number
186872
EAN
4015081819232
Product Length/Depth
248 mm
Product Height
219 mm
Product Width
160 mm
Product Weight
7.5 kg
Certifications
CSA File No.: 012528
UL508
IEC/EN 60947-5-1
CSA
UL Category Control No.: NRNT
CSA Class No.: C321124
CE
IEC/EN 60947-4-1
UL File No.: E338590
CSA-C22.2 No. 14-05
UL
Catalog Notes
DILDC contactors feature an electronic arc suppression system. Because of this, it is important not to exceed any technical data limits in general – especially the making and breaking capacity limits. Opening the device will immediately void the warranty.
Model Code
DILDC400/22(RDS250)

General

Accessories
Fitting options auxiliary contacts: on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA
Application
DC contactor
Degree of protection
IP00
Electromagnetic compatibility
Designed for operation in industrial environments. Its use in residential environments may cause radio-frequency interference, requiring additional noise suppression.
Lifespan, mechanical
1,000,000 Operations (AC operated)
1,000,000 Operations (DC operated)
Operating frequency
100 electrical Operations/h
1000 mechanical Operations/h (AC operated)
1000 mechanical Operations/h (DC operated)
Overvoltage category
III
Pollution degree
3
Product category
Contactors
Protection
Finger and back-of-hand proof with terminal shroud or terminal block, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)
8000 V DC
Shock resistance
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Signal level
5 V - 15 V, PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2), Magnet systems
Voltage type
DC

Condiciones climáticas ambientales

Ambient operating temperature - min
-40 °C
Ambient operating temperature - max
70 °C
Ambient operating temperature (enclosed) - min
-40 °C
Ambient operating temperature (enclosed) - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
80 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78

Secciones de conexión

Terminal capacity (busbar)
40 mm width, Main connection
Terminal capacity (flexible with cable lug)
50 - 240 mm²
Terminal capacity (flexible with ferrule)
1 x (0.75 - 2.5) mm², Control circuit cales
1 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid)
1 x (0.75 - 2.5) mm², Control circuit cales
1 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)
2 x (18 - 12)
1/0 - 500 MCM, Main cables
Terminal capacity (stranded with cable lug)
50 - 240 mm²
Width across flats
16 mm
Screw size
M10, Terminal screw, Main connections
M3.5, Terminal screw, Control circuit cables
Screwdriver size
0.8 x 5.5/1 x 6 mm, Terminal screw, Control circuit cables, Standard screwdriver
2, Terminal screw, Control circuit cables, Pozidriv screwdriver
Tightening torque
1.2 Nm, Screw terminals, Control circuit cables
24 Nm, Main cable connection screw/bolt

Especificaciones eléctricas

Rated breaking capacity at 220/230 V
600 A
Rated breaking capacity at 380/400 V
600 A
Rated breaking capacity at 500 V
600 A
Rated breaking capacity at 660/690 V
600 A
Rated breaking capacity at 1000 V
600 A
Rated insulation voltage (Ui) at DC
1000 V
Rated making capacity (cos phi to IEC/EN 60947)
600 A
Rated operational voltage (Ue) at DC - max
1000 V
Rated operational current (Ie) at DC-1, 1000 V
400 A
Rated operational current (Ie) at DC-3/DC-5 at 440 V
0 A
Short-circuit protection rating
Max. 630 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 1000 V DC, Main conducting paths
Max. 630 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 400 V DC, Main conducting paths
Max. 630 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 690 V DC, Main conducting paths
Max. 630 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 400 V DC, Main conducting paths
Max. 630 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 690 V DC, Main conducting paths
Max. 630 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 1000 V DC, Main conducting paths
Safe isolation
1000 V, Between the contacts, According to EN 61140
1000 V, Between control inputs and main contacts, According to EN 61140
1000 V, Between auxiliary contacts and main contacts, According to EN 61140

Poder de corte

Switching capacity (main contacts, general use)
400 A, Maximum motor rating, Single-phase (UL/CSA)
Switching capacity (auxiliary contacts, general use)
15 A, 600 V AC, (UL/CSA)
1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)
A600, AC operated (UL/CSA)
P300, DC operated (UL/CSA)

Sistema magnético

Drop-out voltage
0.2 x US max - 0.6 x US min, DC operated
AC operated: 0.2 x US max - 0.6 x US min, AC operated
Duty factor
100 %
Pick-up voltage
0.7 - 1.15 V AC x Us
0.7 - 1.15 V DC x Us
Power consumption, pick-up, 50 Hz
600 VA, Pull-in power, Coil in a cold state and 1.0 x Us
550 W, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, pick-up, 60 Hz
550 W, Pull-in power, Coil in a cold state and 1.0 x Us
600 VA, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, sealing, 50 Hz
9.5 W, Coil in a cold state and 1.0 x Us
18 VA, Coil in a cold state and 1.0 x Us
Power consumption, sealing, 60 Hz
18 VA, Coil in a cold state and 1.0 x Us
9.5 W, Coil in a cold state and 1.0 x Us
Rated control supply voltage (Us) at AC, 50 Hz - min
110 V
Rated control supply voltage (Us) at AC, 50 Hz - max
250 V
Rated control supply voltage (Us) at AC, 60 Hz - min
110 V
Rated control supply voltage (Us) at AC, 60 Hz - max
250 V
Rated control supply voltage (Us) at DC - min
110 V
Rated control supply voltage (Us) at DC - max
350 V
Switching time (AC operated, make contacts, closing delay) - max
80 ms
Switching time (AC operated, make contacts, opening delay) - max
40 ms

Contactos

Number of auxiliary contacts (normally closed contacts)
2
Number of auxiliary contacts (normally open contacts)
2
Number of contacts (normally closed contacts)
2
Number of contacts (normally open contacts)
2

Verificación del diseño

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
32 W
Rated operational current for specified heat dissipation (In)
400 A
Static heat dissipation, non-current-dependent Pvs
9 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 186872 Interruptores de baja tensión (EC002552)
Característica Valor
Voltaje nominal de suministro piloto piloto para CA 50 Hz (EF003978) 110 V
Voltaje nominal de suministro piloto piloto para CA 60 Hz (EF003979) 110 V
Voltaje nominal de suministro piloto de piloto para CC (EF003980) 110 V
Tipo de tensión de accionamiento (EF008242) CC
Número de contactos normalmente cerrados como contactos principales (EF001375) 0
Número de contactos normalmente abiertos como contactos principales (EF001374) 2
Tipo de conexión del circuito de corriente principal (EF006819) Carril de conexión
Voltaje de funcionamiento en CC (EF008208) 110 V
Corriente de funcionamiento nominal a 440 V CC-3/CC-5 (EF007035) 0 A
Potencia de funcionamiento nominal a 440 V CC-3/CC-5 (EF007026) 0 kW
Número de contactos auxiliares normalmente abiertos (EF001376) 2
Número de contactos auxiliares normalmente cerrados (EF001377) 2
Apto para instalación en serie (EF001126) No
Anchura (EF000008) 160 mm
Altura (EF000040) 219 mm
Profundidad (EF000049) 248 mm

Datasheet - PDF

Opiniones: (0)

Ningún comentario por el momento.

Añadir comentario
ocultar
Valoración:
Nombre:
Email:
Título:
Opinión:
  Captcha
  Añadir comentario

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.