ANUNCIAR

CS-1212/400-2D 193435 Y7-193435 EATON ELECTRIC CS-1212/400-2D

CS-1212/400-2D

193435

Y7-193435

EATON-MOELLER

CS-1212/400-2D

CS-1212/400-2D. Wall enclosure, +mounting plate, 2-doors, HxWxD=1200x1200x250mm

Más detalles


Cajas y armarios industriales

Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER

Precio total: $807.66
Precio unitario: $807.66
Este precio es por unidad y muestra el valor neto (no incluye impuestos indirectos si son aplicables).

Si nuestro precio no es el mejor solicítenos presupuesto Solicitar presupuesto

Más vendidos

Más Información



Especificaciones generales

Product Name
Eaton xEffect CS enclosure double door
Catalog Number
193435
EAN
9010238020870
Product Length/Depth
400 mm
Product Height
1200 mm
Product Width
1200 mm
Product Weight
91 kg
Certifications
UL (File No. E336299)
IEC/EN 60529
In accordance with Directive 2002/95/EC of the European Parliament and Council
IEC 62262
IEC/EN 62208
Model Code
CS-1212/400-2D

Delivery program

Type
Wall-mounting housing CSWall-mounting housing with mounting plate
Color
Gray
Light gray (RAL 7035)

Technical Data - Mechanical

Surface finishing
Gloss
Structured powder spray polyester based paint finish
With powder coating
Powder coating
Surface treatment
Structured powder spray polyester based paint finish
Mounting method
Wall fastening
9 mm drilling dimensions for wall mounting (Back plate)
Mounting plate material
Sheet steel, hot-galvanized
Material
Steel plate
Steel
Material thickness (bottom plate)
1.5 mm
Material quality
Other
Degree of protection
IK09
IP23 (with ventilating plates)
IP55
IP66
NEMA Other
Number of connector holes
0
Number of covers/doors
2
Number of locks
1
Load capacity (door)
20 kg
Permissible load of the door(s) according to IEC 62208 - max
400 N
Permissible load of the enclosure according to IEC 62208 - max
3900 N
Permissible load of the mounting plate according to IEC 62208 - max
3500 N
Weight of mounted components - max
300 kg
Cover/door angle
120° door opening angle
Cover/door type
Standard closure 3 mm double-ward key (door interlock)
Can be converted by user
Door hinges right
On the right, can be converted by user
Protection insulated turn-buckle door interlock
Installation site
Indoor-/outdoor installation
Climatic proofing
Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30

Temperature-rise verification as per IEC 60890

Heat diss. ambient 35°C delta T: 20°C wall mount middle encl. top (IEC 60890)
220 W
Heat diss. ambient 35°C delta T: 35°C wall mount middle encl. top (IEC 60890)
442 W
Heat diss. ambient 35°C delta T:20°C wall mount individ. encl. top (IEC 60890)
228 W
Heat diss. ambient 35°C delta T:20°C wall mount starting encl. top (IEC 60890)
223 W
Heat diss. ambient 35°C delta T:35°C wall mount individ. encl. top (IEC 60890)
457 W
Heat diss. ambient 35°C delta T:35°C wall mount starting encl. top (IEC 60890)
447 W
Thermal dissipation (Delta T = 20 K) according to IEC/TR 60890
390.72 W

Design verification as per IEC/EN 61439 - technical data

Ambient operating temperature details
-40 °C - 70 °C

Design verification as per IEC/EN 61439

10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply to enclosures without lifting aids.
10.2.6 Mechanical impact
IK09
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
IP55
10.4 Clearances and creepage distances
Is the panel builder's responsibility.
10.5 Protection against electric shock
< 0.1 Ω; meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Ui = 1000 V AC
10.9.3 Impulse withstand voltage
Does not apply to basic enclosures as defined in EN 62208.
10.9.4 Testing of enclosures made of insulating material
Does not apply to metal enclosures.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
Meets the product standard's requirements.

Additional information

Fitted with:
Mounting plate
RAL-number
7035
Special features
Enclosed, foamed gasket, can be unscrewed for F3A-… flanges or for assembly by userLock, 3 mm double ward keyIncluding M6 threaded welded studs for earth conductor connections in the doorWithout apertures
Suitable for
Metrical mounting

Datasheet - PDF

Título: Tamaño: Tipo:
PDF CATALOGO EATON ENVOLVENTES ES.pdf 7 Mbytes
PDF CATALOGUE EATON EN .pdf 38 Mbytes

Opiniones: (0)

Ningún comentario por el momento.

Añadir comentario
ocultar
Valoración:
Nombre:
Email:
Título:
Opinión:
  Captcha
  Añadir comentario

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.