PHOENIX CONTACT  VAL-MS-T1/T2 175/12.5 ST 2800676 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-MS-T1/T2 175/12.5 ST 2800676 PHOENIX CONTACT Type 1/2 surge protection plug

Reference: VAL-MS-T1/T2 175/12.5 ST

Code: 2800676

Manufacturer: PHOENIX CONTACT

Description:

Type 1/2 surge protection plug
Replacement L-N connector for VAL-MS-T1/T2 175/12.5 plug-in lightning/surge current discharger.

Categories:

  • Earthing, lightning and surge protection > Accessories/spare parts for surge protection power supply systems
  • PHOENIX CONTACT > Trabtech (TT)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • PDF
  • Reviews
Guarantee, repair and return.

Total: 1.131,16 €

Unit Price: 113,116 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Key Commercial Data

Orderkey2800676
Packing unit10 pc
Minimum order quantity10 pc
NoteMade to Order (non-returnable)
Catalog pagePage 37 (C-4-2017)
GTIN4046356624350
Weight per Piece (excluding packing)80.000 g
Custom tariff number85363030
Country of originDE (Germany)

Dimensions

Height47 mm
Width17.5 mm
Depth67.3 mm
Horizontal pitch1 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

IEC test classificationI / II
T1 / T2
I
EN typeT1 / T2
IEC power supply systemTN-C
TT
Mode of protectionL-N
L-PEN
Mounting typeon base element
Colorjet black RAL 9005
Housing materialPA 6.6
PBT
Degree of pollution2
Flammability rating according to UL 94V-0
TypeMale
Surge protection fault messageoptical

Protective circuit

Nominal voltage UN120/208 V AC (TN-C, TN-S)
120/208 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC175 V AC
Residual current IPE≤ 800 µA
Standby power consumption PC≤ 140 mVA
Nominal discharge current In(8/20) µs12.5 kA
Maximum discharge current Imax(8/20) µs50 kA
Impulse discharge current (10/350) µs, charge6.25 As
Impulse discharge current (10/350) µs, specific energy39 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp12.5 kA
Short-circuit current rating ISCCR25 kA
Voltage protection level Up≤ 0.8 kV
Residual voltage Ures≤ 0.8 kV (at In)
≤ 0.7 kV (at 10 kA)
≤ 0.6 kV (at 5 kA)
≤ 0.5 kV (at 3 kA)
TOV behavior at UT208 V AC (5 s / withstand mode)
229 V AC (120 min / withstand mode)
Response time tA≤ 25 ns
Max. backup fuse with branch wiring160 A (gG)

UL specifications

SPD Type4CA
Maximum continuous operating voltage MCOV (L-N)175 V AC
Nom. voltage120 V AC
Mode of protectionL-N
Power distribution systemSingle phase
Nominal frequency50/60 Hz
Measured limiting voltage MLV (L-N)2200 V
Nominal discharge current In(L-N)20 kA

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Classifications

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.