SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ML5632-8AL21-1GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL21-1GA0
Reference: 7ML5632-8AL21-1GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid:
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Clas
Delivery: See availability
7ML5632-8AL21-1GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL21-1GB0
Reference: 7ML5632-8AL21-1GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid:
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Clas
Delivery: See availability
7ML5632-8AL21-1GC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL21-1GC0
Reference: 7ML5632-8AL21-1GC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid:
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Clas
Delivery: See availability
7ML5632-8AL21-1GD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL21-1GD0
Reference: 7ML5632-8AL21-1GD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid:
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Clas
Delivery: See availability
7ML5632-8AL21-1HA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL21-1HA0
Reference: 7ML5632-8AL21-1HA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General Purpose (CSA, FM) Case & Lid: Aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Delivery: See availability
7ML5632-8AL21-1HB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL21-1HB0
Reference: 7ML5632-8AL21-1HB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5632-8AL21-1HC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL21-1HC0
Reference: 7ML5632-8AL21-1HC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General Purpose (CSA, FM) Enclosure & Lid: Aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, I
Delivery: See availability
7ML5632-8AL21-1HD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL21-1HD0
Reference: 7ML5632-8AL21-1HD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability
7ML5728-3CA11-3DB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3CA11-3DB0
Reference: 7ML5728-3CA11-3DB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-3CC11-2FC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3CC11-2FC0
Reference: 7ML5728-3CC11-2FC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-3EB11-5EB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EB11-5EB0
Reference: 7ML5728-3EB11-5EB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Racket: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Racket: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-3EB21-1BA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EB21-1BA0
Reference: 7ML5728-3EB21-1BA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 125 mm (4.92 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 125 mm (4.92 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 125 mm (4.92 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-3EC11-4EA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EC11-4EA0
Reference: 7ML5728-3EC11-4EA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-3EC11-3DE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EC11-3DE0
Reference: 7ML5728-3EC11-3DE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-3GB11-1EB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3GB11-1EB0
Reference: 7ML5728-3GB11-1EB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 125 mm (4.92 inches) Size Racket: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 125 mm (4.92 inches) Size Racket: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 125 mm (4.92 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-3GC11-2EB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3GC11-2EB0
Reference: 7ML5728-3GC11-2EB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-3JB11-3EB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JB11-3EB0
Reference: 7ML5728-3JB11-3EB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-3JB11-5DC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JB11-5DC0
Reference: 7ML5728-3JB11-5DC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5632-8AL31-1FD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL31-1FD0
Reference: 7ML5632-8AL31-1FD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable in
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class II
Delivery: See availability
7ML5632-8AL31-1GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL31-1GA0
Reference: 7ML5632-8AL31-1GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid:
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Cla
Delivery: See availability
7ML5632-8BA01-1KD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA01-1KD0
Reference: 7ML5632-8BA01-1KD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) with WHG approval Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Compact design 98 mm (3.86") Thermal insulator: Without thermal insulation Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability
7ML5632-8BA11-0CA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0CA0
Reference: 7ML5632-8BA11-0CA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated,
Delivery: See availability
7ML5632-8BA11-0CB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0CB0
Reference: 7ML5632-8BA11-0CB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated,
Delivery: See availability
7ML5632-8BA11-0CC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0CC0
Reference: 7ML5632-8BA11-0CC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated,
Delivery: See availability
7ML5632-8BA11-0CD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0CD0
Reference: 7ML5632-8BA11-0CD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated,
Delivery: See availability
7ML5632-8BA11-0DA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0DA0
Reference: 7ML5632-8BA11-0DA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Flameproof Enclosure With IS Probe CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T 100 C Enclosure and Lid: Aluminum epoxy coated 2X
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure (explosion-proof) with intrinsically safe (IS) probe CE, C-TICK, ATE
Delivery: See availability
7ML5632-8BA11-0DB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0DB0
Reference: 7ML5632-8BA11-0DB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Flameproof Enclosure With IS Probe CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T 100 C Enclosure and Lid: Aluminum epoxy coated 2 x
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure (explosion-proof) with intrinsically safe (IS) probe CE, C-TICK, ATE
Delivery: See availability
7ML5632-8BA11-0DC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0DC0
Reference: 7ML5632-8BA11-0DC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Flameproof Enclosure With IS Probe CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T 100 C Enclosure and Lid: Aluminum epoxy coated 2 x
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure (explosion-proof) with intrinsically safe (IS) probe CE, C-TICK, ATE
Delivery: See availability
7ML5632-8BA11-0DD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0DD0
Reference: 7ML5632-8BA11-0DD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Flameproof Enclosure With IS Probe CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T 100 C Enclosure and Lid: Aluminum epoxy coated 2 x
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure (explosion-proof) with intrinsically safe (IS) probe CE, C-TICK, ATE
Delivery: See availability
7ML5632-8BA11-0EA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0EA0
Reference: 7ML5632-8BA11-0EA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/2
Delivery: See availability
7ML5632-8BA11-0EB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0EB0
Reference: 7ML5632-8BA11-0EB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/2
Delivery: See availability
7ML5632-8BA11-0EC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0EC0
Reference: 7ML5632-8BA11-0EC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/2
Delivery: See availability
7ML5632-8BA11-0ED0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0ED0
Reference: 7ML5632-8BA11-0ED0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/2
Delivery: See availability
7ML5728-3JC11-2AE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JC11-2AE0
Reference: 7ML5728-3JC11-2AE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5632-8AG21-1FD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AG21-1FD0
Reference: 7ML5632-8AG21-1FD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inl
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III
Delivery: See availability
7ML5632-8AL01-1JC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL01-1JC0
Reference: 7ML5632-8AL01-1JC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulation: Without thermal insulation Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68
Delivery: See availability
7ML5728-3CC11-2FD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3CC11-2FD0
Reference: 7ML5728-3CC11-2FD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Racket: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Racket: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-3EB11-5EC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EB11-5EC0
Reference: 7ML5728-3EB11-5EC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-3EB21-1BB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EB21-1BB0
Reference: 7ML5728-3EB21-1BB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 125 mm (4.92 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 125 mm (4.92 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 125 mm (4.92 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-3EC11-4EB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EC11-4EB0
Reference: 7ML5728-3EC11-4EB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Racket: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Racket: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-3GB11-1EC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3GB11-1EC0
Reference: 7ML5728-3GB11-1EC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 125 mm (4.92 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 125 mm (4.92 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 125 mm (4.92 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-3GB11-2DC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3GB11-2DC0
Reference: 7ML5728-3GB11-2DC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Shovel: Rectangular Shovel, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Shovel: Rectangular Shovel, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-3GC11-2EC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3GC11-2EC0
Reference: 7ML5728-3GC11-2EC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Measurement: Rectangular Shovel, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Measurement: Rectangular Shovel, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-3JB11-5DD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JB11-5DD0
Reference: 7ML5728-3JB11-5DD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-3JC11-2AF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JC11-2AF0
Reference: 7ML5728-3JC11-2AF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Rectangular Shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Rectangular Shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5632-8AG21-1GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AG21-1GA0
Reference: 7ML5632-8AG21-1GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid:
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Clas
Delivery: See availability
7ML5632-8AL01-1JD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL01-1JD0
Reference: 7ML5632-8AL01-1JD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulation: Without thermal insulation Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability
7ML5728-3CC11-2FE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3CC11-2FE0
Reference: 7ML5728-3CC11-2FE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Shovel: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Shovel: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-3EB11-5ED0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EB11-5ED0
Reference: 7ML5728-3EB11-5ED0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Rectangular Shovel, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Rectangular Shovel, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-3EC11-4EC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EC11-4EC0
Reference: 7ML5728-3EC11-4EC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-3EC11-4EE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EC11-4EE0
Reference: 7ML5728-3EC11-4EE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-3GB11-1ED0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3GB11-1ED0
Reference: 7ML5728-3GB11-1ED0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 125 mm (4.92 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 125 mm (4.92 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 125 mm (4.92 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-3GB11-2DD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3GB11-2DD0
Reference: 7ML5728-3GB11-2DD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-3GC11-2ED0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3GC11-2ED0
Reference: 7ML5728-3GC11-2ED0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Rectangular Shovel, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Rectangular Shovel, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-3JB11-5DE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JB11-5DE0
Reference: 7ML5728-3JB11-5DE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-3JC11-2BA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JC11-2BA0
Reference: 7ML5728-3JC11-2BA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-3JC11-5FD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JC11-5FD0
Reference: 7ML5728-3JC11-5FD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5632-8AG21-1GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AG21-1GB0
Reference: 7ML5632-8AG21-1GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid:
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Clas
Delivery: See availability
7ML5632-8AL01-1KA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL01-1KA0
Reference: 7ML5632-8AL01-1KA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) with WHG approval Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulation: Without thermal insulation Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Delivery: See availability
7ML5728-3CC11-2FF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3CC11-2FF0
Reference: 7ML5728-3CC11-2FF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-3EB11-5EE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EB11-5EE0
Reference: 7ML5728-3EB11-5EE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 0.5 bar (7.25 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5632-8AL31-1GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL31-1GB0
Reference: 7ML5632-8AL31-1GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid:
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Cla
Delivery: See availability
7ML5632-8AL31-1GC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL31-1GC0
Reference: 7ML5632-8AL31-1GC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid:
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Cla
Delivery: See availability
7ML5632-8AL31-1GD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL31-1GD0
Reference: 7ML5632-8AL31-1GD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid:
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Cla
Delivery: See availability
7ML5632-8BA11-1DC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1DC0
Reference: 7ML5632-8BA11-1DC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Flameproof Enclosure With IS Probe CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T 100 C Enclosure and Lid: Aluminum epoxy coated 2
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure (explosion-proof) with intrinsically safe (IS) probe CE, C-TICK, AT
Delivery: See availability
7ML5632-8AL31-1HA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL31-1HA0
Reference: 7ML5632-8AL31-1HA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General Purpose (CSA, FM) Case & Lid: Aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Delivery: See availability
7ML5632-8BA11-1DD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1DD0
Reference: 7ML5632-8BA11-1DD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Flameproof Enclosure With IS Probe CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T 100 C Enclosure and Lid: Aluminum epoxy coated 2
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure (explosion-proof) with intrinsically safe (IS) probe CE, C-TICK, AT
Delivery: See availability
7ML5632-8AL31-1HB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL31-1HB0
Reference: 7ML5632-8AL31-1HB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5632-8BA11-1EA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1EA0
Reference: 7ML5632-8BA11-1EA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminu
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/
Delivery: See availability
7ML5632-8BA11-1EB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1EB0
Reference: 7ML5632-8BA11-1EB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminu
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/
Delivery: See availability
7ML5632-8BA11-1EC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1EC0
Reference: 7ML5632-8BA11-1EC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminu
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/
Delivery: See availability
7ML5632-8BA11-1ED0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1ED0
Reference: 7ML5632-8BA11-1ED0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminu
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/
Delivery: See availability
7ML5632-8BA11-1FA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1FA0
Reference: 7ML5632-8BA11-1FA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cabl
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F,
Delivery: See availability
7ML5632-8BA11-1FB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1FB0
Reference: 7ML5632-8BA11-1FB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 ca
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F,
Delivery: See availability
7ML5632-8BA11-1FC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1FC0
Reference: 7ML5632-8BA11-1FC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F,
Delivery: See availability
7ML5632-8BA11-1FD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1FD0
Reference: 7ML5632-8BA11-1FD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 ca
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F,
Delivery: See availability
7ML5632-8BA11-1GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1GA0
Reference: 7ML5632-8BA11-1GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure an
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A,
Delivery: See availability
7ML5632-8BA11-1GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1GB0
Reference: 7ML5632-8BA11-1GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure an
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A,
Delivery: See availability
7ML5632-8BA11-1GC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1GC0
Reference: 7ML5632-8BA11-1GC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure an
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A,
Delivery: See availability
7ML5632-8BA11-1GD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1GD0
Reference: 7ML5632-8BA11-1GD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure an
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A,
Delivery: See availability
7ML5632-8BA11-1HA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1HA0
Reference: 7ML5632-8BA11-1HA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General Purpose (CSA, FM) Case & Lid: Aluminum, epoxy coated, 2 x 1/2" NPT via adapter -
Delivery: See availability
7ML5632-8BA11-1HB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1HB0
Reference: 7ML5632-8BA11-1HB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, I
Delivery: See availability
7ML5632-8BA11-1HC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1HC0
Reference: 7ML5632-8BA11-1HC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General Purpose (CSA, FM) Enclosure & Lid: Aluminum, epoxy coated, 2 x 1/2" NPT via adapt
Delivery: See availability
7ML5632-8BA11-1HD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1HD0
Reference: 7ML5632-8BA11-1HD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, I
Delivery: See availability
7ML5632-8BA11-0FA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0FA0
Reference: 7ML5632-8BA11-0FA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F,
Delivery: See availability
7ML5632-8BA11-1JA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1JA0
Reference: 7ML5632-8BA11-1JA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter -
Delivery: See availability
7ML5632-8BA11-0FB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0FB0
Reference: 7ML5632-8BA11-0FB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cab
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F,
Delivery: See availability
7ML5632-8BA11-1JB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1JB0
Reference: 7ML5632-8BA11-1JB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry
Delivery: See availability
7ML5632-8BA11-0FC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0FC0
Reference: 7ML5632-8BA11-0FC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F,
Delivery: See availability
7ML5632-8BA11-0FD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0FD0
Reference: 7ML5632-8BA11-0FD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cab
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F,
Delivery: See availability
7ML5632-8BA11-1JC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1JC0
Reference: 7ML5632-8BA11-1JC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter -
Delivery: See availability
7ML5632-8BA11-1JD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1JD0
Reference: 7ML5632-8BA11-1JD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry
Delivery: See availability
7ML5632-8AL31-1HC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL31-1HC0
Reference: 7ML5632-8AL31-1HC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General Purpose (CSA, FM) Enclosure & Lid: Aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry,
Delivery: See availability
7ML5632-8AL31-1HD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL31-1HD0
Reference: 7ML5632-8AL31-1HD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability
7ML5632-8BA21-1GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA21-1GB0
Reference: 7ML5632-8BA21-1GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Alum
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulator: Separate electronics with 2 m (79") of cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM
Delivery: See availability
7ML5632-8BA31-1FB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA31-1FB0
Reference: 7ML5632-8BA31-1FB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class I
Delivery: See availability
7ML5632-8BA11-0GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-0GA0
Reference: 7ML5632-8BA11-0GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B
Delivery: See availability
7ML5632-8BA11-1KA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA11-1KA0
Reference: 7ML5632-8BA11-1KA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) with WHG approval Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulation: Thermally insulated (for process connection temperatures above +85 °C (+185 F)) Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2"
Delivery: See availability
7ML5632-8BA21-1GC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA21-1GC0
Reference: 7ML5632-8BA21-1GC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Alum
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulator: Separate electronics with 2 m (79") of cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM
Delivery: See availability
7ML5632-8BA31-1FD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA31-1FD0
Reference: 7ML5632-8BA31-1FD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class I
Delivery: See availability

products sitemap